Benchtop Ultrapure Water System — product photo

Benchtop Ultrapure Water System

台式超纯水系统

  • SKU UWS-0001
  • Ultrapure Water Systems
  • CE (to be confirmed)
  • RoHS (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Resistivity18.2 MΩ·cm at 25 °C
Total organic carbon< 5–10 ppb
Flow rate0.5–2 L/min
Feed qualityRO or distilled, < 10 µS/cm
UV lamps185 nm and 254 nm
Final filter0.22 µm or ultrafiltration
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 3696, CLSI GP40, USP <643>

What is the Benchtop Ultrapure Water System?

A benchtop ultrapure water system produces Type I water at the point of use from pretreated feed. It is the standard unit for trace analysis, molecular biology, PCR and small-volume laboratory work.

What is the Benchtop Ultrapure Water System?

A benchtop ultrapure water system produces Type I water at the point of use from pretreated feed. It is the standard unit for trace analysis, molecular biology, PCR and small-volume laboratory work.

Overview

The benchtop ultrapure system typically includes a pretreatment cartridge, a mixed-bed ion exchange cartridge, a 185 and 254 nanometer UV lamp, and a final 0.22 micron filter or ultrafiltration module. Feed is reverse osmosis or distilled water, and output ranges from 0.5 to 2 liters per minute with resistivity near 18.2 megohm-centimeters and total organic carbon below 5 to 10 parts per billion. An internal tank or a loop keeps water circulating, and a dispensing gun or valve delivers it. Monitoring covers resistivity and sometimes total organic carbon, with alarms for out-of-range values. The unit sits on the bench or on a wall bracket and needs only a feed connection, a drain and power. Cartridges are replaced on schedule, and sanitization is part of routine maintenance.

How does it work?

An ultrapure water system chains several purification steps to reach Type I quality. Feed, usually reverse osmosis or distilled water, passes through activated carbon to remove organics and chlorine, ion exchange resin to remove ions, a 185 nanometer ultraviolet lamp to oxidize residual organics, a 254 nanometer lamp to inactivate microorganisms, and ultrafiltration or microfiltration to remove particles, bacteria and endotoxins. A final 0.22 micron filter or ultrafiltration membrane polishes the water at the point of use. Resistivity and total organic carbon are monitored continuously, and recirculation keeps the loop fresh. The combination of steps is essential because no single technique removes all contaminant classes, and care in materials, dead volume and loop design prevents the purified water from being re-contaminated before it is dispensed.

What are the key features?

  • Pretreatment, mixed-bed and UV purification steps
  • Resistivity near 18.2 MΩ·cm from pretreated feed
  • Total organic carbon below 5–10 ppb
  • Output of 0.5–2 L/min with dispensing gun
  • Recirculation to keep water fresh
  • Resistivity monitoring with alarms

What are the technical specifications?

A typical benchtop ultrapure water system configuration offers resistivity of 18.2 MΩ·cm at 25 °C, total organic carbon of < 5–10 ppb, flow rate of 0.5–2 L/min, feed quality of RO or distilled, < 10 µS/cm, UV lamps of 185 nm and 254 nm and final filter of 0.22 µm or ultrafiltration. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Benchtop Ultrapure Water System is used in trace analysis reagent water, HPLC and LC-MS mobile phases, molecular biology and PCR, cell culture media preparation and immunoassay reagent dilution. Across the wider Ultrapure Water Systems class, laboratories also deploy it for trace metal and ion analysis, HPLC, LC-MS and UHPLC mobile phases and molecular biology and PCR.

Which standards and certifications apply?

Relevant standards and methods include ISO 3696, CLSI GP40, USP <643>, USP <645>, IEC 61010-1 and ISO 9001. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Maintain the system on the manufacturer's schedule: replace pretreatment and polishing cartridges, and the UV lamps, before performance declines. Keep the recirculation loop short and flowing, because stagnant water allows biofilm to form on wetted surfaces and raises total organic carbon. Sanitize on a defined interval and after any contamination event, and verify with resistivity and microbial testing. Handle the point-of-use filter carefully to avoid contamination, and touch only the connector. Draw water just before use and do not store Type I water for long, since its purity degrades in containers. Follow IEC 61010-1 for electrical safety, and document resistivity, total organic carbon and service dates for traceability.

How do I select the right Benchtop Ultrapure Water System?

Choose a benchtop unit for a single point of use where the analytical method needs Type I water. If high volumes are also needed, choose a combined Type I and Type II system. In the RFQ, state feed, flow, purity targets and monitoring needs.

How does it compare with other Ultrapure Water Systems variants?

Start from the analytical method, because it determines the required resistivity, total organic carbon, bacterial and endotoxin limits. Trace metals and ion chromatography need low ionic content, LC-MS needs low organic carbon, and cell culture needs low endotoxin and bacteria. Choose a system with the purification steps that meet those requirements, and confirm that resistivity and total organic carbon are monitored, ideally with a calibration option. Size the unit by daily volume and instantaneous flow, and decide whether it should produce Type I only or both Type I and Type II. Consider the feed source, since reverse osmosis feed extends cartridge life compared with tap water. Check the point-of-use dispenser, dead volume, recirculation, sanitization procedure and consumable cost per liter before selecting.

Full specifications

Full specifications
Resistivity18.2 MΩ·cm at 25 °C
Total organic carbon< 5–10 ppb
Flow rate0.5–2 L/min
Feed qualityRO or distilled, < 10 µS/cm
UV lamps185 nm and 254 nm
Final filter0.22 µm or ultrafiltration
Bacteria< 1 CFU/mL
DispenserGun or valve, point of use
MonitoringResistivity, optional TOC
Power supply100–240 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Trace analysis reagent water
  • HPLC and LC-MS mobile phases
  • Molecular biology and PCR
  • Cell culture media preparation
  • Immunoassay reagent dilution

Key features

  • Pretreatment, mixed-bed and UV purification steps
  • Resistivity near 18.2 MΩ·cm from pretreated feed
  • Total organic carbon below 5–10 ppb
  • Output of 0.5–2 L/min with dispensing gun
  • Recirculation to keep water fresh
  • Resistivity monitoring with alarms

Frequently asked questions about Benchtop Ultrapure Water System

It can, but the cartridges exhaust quickly and final quality may drift. Feed it with reverse osmosis or distilled water to reach the full 18.2 megohm-centimeters and keep running costs reasonable.

Request a quotation for the Benchtop Ultrapure Water System

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote