Zonal and Continuous-Flow Ultracentrifuge
区带和连续流超速离心机
- SKU ULT-0004
- Ultracentrifuges
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- GMP-oriented documentation (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Maximum speed | 25,000–50,000 rpm |
|---|---|
| Maximum RCF | approx. 50,000–100,000 x g |
| Rotor volume | 0.5–3 L |
| Continuous-flow throughput | 0.5–10 L/h |
| Gradient types | Sucrose, iodixanol, cesium chloride (model-dependent) |
| Temperature range | 0 to 40 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-020, IEC 61326-1
What is the Zonal and Continuous-Flow Ultracentrifuge?
A zonal or continuous-flow ultracentrifuge uses a large-volume rotor with a rotating seal to process liters of feed at 25,000 to 50,000 rpm. It is used for industrial-scale virus and vaccine purification, where gradient loading and unloading occur while the rotor spins.
What is the Zonal and Continuous-Flow Ultracentrifuge?
A zonal or continuous-flow ultracentrifuge uses a large-volume rotor with a rotating seal to process liters of feed at 25,000 to 50,000 rpm. It is used for industrial-scale virus and vaccine purification, where gradient loading and unloading occur while the rotor spins.
Overview
Zonal and continuous-flow rotors hold 0.5 to 3 L of liquid in a single cylindrical bowl rather than in tubes. A rotating seal assembly and external pump allow gradient solutions and feed to be loaded into the spinning rotor, and fractions to be unloaded without stopping. In zonal mode, particles separate into bands within a sucrose or iodixanol gradient formed from the rim inward. In continuous-flow mode, feed moves through the rotor at 0.5 to 10 L per hour while particles sediment onto the wall or a gradient cushion. Maximum speeds are 25,000 to 50,000 rpm, giving 50,000 to 100,000 x g. Systems require a robust floor-standing ultracentrifuge, a gradient maker, peristaltic pumps and a fraction collector. Closed-system and stainless-steel options support biosafety and GMP-oriented processing.
How does it work?
An ultracentrifuge drives a titanium or carbon fiber rotor through a high-frequency induction or brushless motor, typically with a magnetically suspended or oil-lubricated flexible shaft. The chamber is evacuated below 0.1 Pa (1 micron Hg) by a rotary vane and diffusion or turbomolecular pump, eliminating air friction that would otherwise overheat the rotor. Refrigeration controls rotor temperature via infrared sensing, usually between 0 and 40 C. Particles sediment according to Stokes' law, with sedimentation coefficients measured in Svedberg units, in preparative runs, or are separated by buoyant density in cesium chloride, sucrose or iodixanol gradients in isopycnic runs. Rotors are identified automatically, and the control system tracks run hours and cycles to derate them. A heavy armor ring contains rotor fragments in the event of failure.
What are the key features?
- Bowl rotor holds 0.5 to 3 L of feed without individual tubes
- Rotating seal allows loading and unloading of gradients while spinning
- Continuous-flow mode processes 0.5 to 10 L per hour of feed
- Closed-system and stainless-steel options support biosafety and process control
- Fraction collector and pumps give reproducible fractionation of bands
What are the technical specifications?
A typical zonal and continuous-flow ultracentrifuge configuration offers maximum speed of 25,000–50,000 rpm, maximum RCF of approx. 50,000–100,000 x g, rotor volume of 0.5–3 L, continuous-flow throughput of 0.5–10 L/h, gradient types of Sucrose, iodixanol, cesium chloride (model-dependent) and temperature range of 0 to 40 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Zonal and Continuous-Flow Ultracentrifuge is used in vaccine and virus purification, large-volume gradient fractionation, viral vector manufacturing support and industrial cell organelle recovery. Across the wider Ultracentrifuges class, laboratories also deploy it for virus and viral vector purification, exosome and extracellular vesicle isolation and lipoprotein fractionation.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-020, IEC 61326-1, ISO 9001, EN 12469 and GB 4793.1. Certification candidates for this model are CE, ISO 9001 manufacturing and GMP-oriented documentation; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Floor-standing units weigh 200 to 450 kg and often require a dedicated 220 V or 380 V circuit and a level, vibration-free floor. Rotor management is critical: log every run, derate titanium and aluminum rotors per the maker's schedule, and retire rotors at the stated lifetime. Use only tubes and adapters certified for the rotor, and fill them as specified. Vacuum pumps need periodic oil changes, and seals require inspection. Clean rotors with neutral detergent and never use chloride or strong alkali on aluminum. Annual preventive maintenance should include speed, temperature and vacuum checks. Install and operate in line with IEC 61010-2-020 and local pressure-vessel and biosafety rules.
How do I select the right Zonal and Continuous-Flow Ultracentrifuge?
Select zonal or continuous-flow when volumes of liters must be purified, which tube-based siblings cannot handle efficiently. It requires trained operators, pumps and a gradient maker. In the RFQ, specify volume per batch, gradient media, flow rate, wetted materials, containment needs and three-phase power availability.
How does it compare with other Ultracentrifuges variants?
Specify the maximum RCF needed: 100,000 to 150,000 x g suits most gradient and pelleting work, while ribosomes, small viruses and proteins need 300,000 to 600,000 x g or analytical capability. Choose rotor geometry to match the task, with swing-bucket rotors for gradients, fixed-angle rotors for pelleting, vertical or near-vertical rotors for fast gradients and zonal or continuous-flow rotors for large volumes. Consider tube materials and sealing, because ultracentrifuge tubes require heat-sealed or cap-assembled closures. Evaluate run documentation, rotor life tracking, temperature range, vacuum time, noise, and installation needs including weight, power and cooling water. For multi-user facilities, autoclavable rotors and biosafety containment options matter.
Full specifications
| Maximum speed | 25,000–50,000 rpm |
|---|---|
| Maximum RCF | approx. 50,000–100,000 x g |
| Rotor volume | 0.5–3 L |
| Continuous-flow throughput | 0.5–10 L/h |
| Gradient types | Sucrose, iodixanol, cesium chloride (model-dependent) |
| Temperature range | 0 to 40 °C |
| Rotor material | Titanium or aluminum alloy |
| Wetted materials | Stainless steel, PTFE, silicone |
| Noise level | ≤ 65 dB(A) |
| Power supply | 380 V three-phase, 50/60 Hz, 5–8 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Vaccine and virus purification
- Large-volume gradient fractionation
- Viral vector manufacturing support
- Industrial cell organelle recovery
Key features
- Bowl rotor holds 0.5 to 3 L of feed without individual tubes
- Rotating seal allows loading and unloading of gradients while spinning
- Continuous-flow mode processes 0.5 to 10 L per hour of feed
- Closed-system and stainless-steel options support biosafety and process control
- Fraction collector and pumps give reproducible fractionation of bands
Frequently asked questions about Zonal and Continuous-Flow Ultracentrifuge
Zonal centrifugation separates particles in a preformed density gradient loaded into a large cylindrical rotor. Particles form distinct zones by size or density, and gradient fractions are pumped out during or after the run, giving high-resolution separation at liter scale.
Yes. It is commonly used to concentrate and purify viruses from large harvest volumes, often followed by a zonal gradient. Flow rate must be tuned so small virus particles have sufficient residence time to sediment at the chosen speed.
Rotors must be loaded, balanced and sealed according to the manufacturer's procedure, run only at rated speed with correct fluid density, and inspected for cracks or corrosion. Leaks at the rotating seal must be checked before each run.
A preparative ultracentrifuge separates and recovers material by spinning tubes in a rotor. An analytical ultracentrifuge has optical detection, such as absorbance or interference, to measure sedimentation in real time in special cells, yielding molecular weight, shape and interaction parameters.
At speeds above about 20,000 rpm, air friction would heat and slow the rotor and make temperature control impossible. Evacuating the chamber below 0.1 Pa eliminates drag and heat, allowing speeds up to 100,000 rpm with stable temperature and lower power consumption.
Lifespan depends on material, speed and run count. Titanium rotors may be rated for 10 years or a set number of cycles, while aluminum rotors are derated with age and cycles. The instrument tracks use, and rotors must be retired at the published limit.