Multi-Parameter Tablet Tester for Thickness, Diameter and Weight
片剂厚度、直径及重量多参数测试仪
- SKU THT-0004
- Thickness Testers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Parameters measured | Thickness, diameter, weight |
|---|---|
| Thickness range | 0.5–15 mm |
| Diameter range | 3–25 mm |
| Thickness resolution | 0.001 mm |
| Weight range | 0–220 g |
| Weight readability | 1 mg |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1217>, Ph. Eur. 2.9.8, ISO 13385-1
What is the Multi-Parameter Tablet Tester for Thickness, Diameter and Weight?
A multi-parameter tablet tester measures thickness, diameter and weight of each tablet in one cycle, with an integrated balance. It is used where dimensional data must be collected alongside weight for statistical batch control.
What is the Multi-Parameter Tablet Tester for Thickness, Diameter and Weight?
A multi-parameter tablet tester measures thickness, diameter and weight of each tablet in one cycle, with an integrated balance. It is used where dimensional data must be collected alongside weight for statistical batch control.
Overview
This variant integrates a thickness and diameter sensor with an analytical balance, usually 1 mg readability or better, in one housing. The operator places a tablet into the measuring station, or an automatic feeder presents tablets one at a time, and the instrument records weight, thickness and diameter within a few seconds. Software calculates mean, standard deviation and relative standard deviation for each parameter, flags values outside the set limits, and generates batch reports. Combining parameters saves time, prevents transcription errors and allows correlation between weight and thickness, which helps to identify compression problems. Some models add a hardness module for a complete tablet test station. The larger footprint and the balance need a stable environment, and each sensor requires its own calibration.
How does it work?
Thickness is measured either by contact or without contact. A contact tester places the tablet between a fixed anvil and a spring-loaded or motor-driven measuring probe, and a digital encoder or linear scale converts probe displacement into a thickness value, typically with 0.01 mm resolution. Non-contact testers use a laser or light-curtain sensor that measures the shadow or reflected light of the tablet, so soft or fragile units are not deformed. Diameter can be measured by a second probe or sensor placed perpendicular to the first. Key components are the measuring head, a controlled measuring force, the anvil, a display or software, and often an automatic feeding or alignment system. Results are logged as individual values with mean and standard deviation for batch statistics and trend charts.
What are the key features?
- Thickness, diameter and weight recorded from one loading
- Balance readability of 1 mg or better in the same housing
- Batch statistics with limit flags for each parameter
- Optional automatic feeder for continuous testing
- Report export for batch records and trend analysis
What are the technical specifications?
A typical multi-parameter tablet tester for thickness, diameter and weight configuration offers parameters measured of Thickness, diameter, weight, thickness range of 0.5–15 mm, diameter range of 3–25 mm, thickness resolution of 0.001 mm, weight range of 0–220 g and weight readability of 1 mg. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Multi-Parameter Tablet Tester for Thickness, Diameter and Weight is used in tablet production IPC stations, weight and dimension correlation, GMP batch records and tooling qualification. Across the wider Thickness Testers class, laboratories also deploy it for tablet compression monitoring, dimensional QC of finished tablets and formulation and tooling development.
Which standards and certifications apply?
Relevant standards and methods include USP <1217>, Ph. Eur. 2.9.8, ISO 13385-1 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the tester on a stable bench away from drafts and vibration, and allow it to equilibrate to room temperature. Verify the zero and span with certified gauge blocks at installation and at defined intervals, and check measuring force with a force gauge where applicable. Keep the anvil and probe clean, since tablet dust and coating residue cause drift. Record the measurement force and orientation of tablets, because different orientations produce different readings for non-round tablets. For optical sensors, keep lenses free of dust and check alignment. Under GMP, qualify the instrument, control software access and keep calibration records traceable to national standards.
How do I select the right Multi-Parameter Tablet Tester for Thickness, Diameter and Weight?
Choose this variant when weight and dimensions are routinely measured together. Separate gauges cost less if only thickness is needed. In an RFQ, specify weight range and readability, dimension ranges, feeder type, statistics, reporting format and any need for an added hardness module.
How does it compare with other Thickness Testers variants?
Start from the required measuring range and resolution, typically 0.01 mm for tablets. Choose contact measurement for robust tablets with a simple, low-cost workflow, and non-contact measurement for soft, sticky or coated units where probe force could deform the sample. Decide whether diameter or length is needed, since multi-parameter units add sensors. For high sample counts, automatic feeding reduces operator time. Confirm that the instrument handles odd shapes such as oblong or capsule-shaped tablets, because alignment matters. Check measuring force adjustment, because excessive force compresses soft tablets. For regulated labs, look for data export, statistical reports and traceable calibration with gauge blocks. A combined tester with hardness and weight measurement may save space when multiple properties are tested routinely.
Full specifications
| Parameters measured | Thickness, diameter, weight |
|---|---|
| Thickness range | 0.5–15 mm |
| Diameter range | 3–25 mm |
| Thickness resolution | 0.001 mm |
| Weight range | 0–220 g |
| Weight readability | 1 mg |
| Cycle time | approx. 5 s per tablet |
| Sample feed | Manual or automatic |
| Data output | USB / Ethernet / printer |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Tablet production IPC stations
- Weight and dimension correlation
- GMP batch records
- Tooling qualification
Key features
- Thickness, diameter and weight recorded from one loading
- Balance readability of 1 mg or better in the same housing
- Batch statistics with limit flags for each parameter
- Optional automatic feeder for continuous testing
- Report export for batch records and trend analysis
Frequently asked questions about Multi-Parameter Tablet Tester for Thickness, Diameter and Weight
Yes. The balance should be calibrated and verified like any analytical balance, with certified weights, and checked for drift before each batch session. Thickness and diameter sensors have separate calibration.
A typical cycle takes about 5 seconds per tablet, so 20 tablets take under two minutes. Automatic feeding keeps the pace consistent, while manual loading depends on the operator.
Some models add a hardness module so that thickness, diameter, weight and breaking force are measured on the same tablet. Confirm which combinations are supported and validate the sequence for your method.
A tablet thickness tester measures the thickness of tablets, and often their diameter, with a contact probe or optical sensor. It supports compression control and dimensional checks, because thickness varies with fill weight, compression force and tooling condition.
Thickness affects hardness, disintegration, weight uniformity and packaging fit. A drift in thickness often signals a change in fill weight or compression force, so it is a simple early-warning parameter in production.
Contact gauges are simple and accurate for robust tablets, while non-contact optical methods avoid deformation of soft or coated units. The better choice depends on tablet hardness, shape and throughput needs.