Chemisorption Analyzer for Catalyst Metal Dispersion and TPR/TPD — product photo

Chemisorption Analyzer for Catalyst Metal Dispersion and TPR/TPD

催化剂金属分散度及 TPR/TPD 化学吸附分析仪

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Measurement modesPulse chemisorption, TPR, TPD, TPO
Furnace temperature rangeAmbient to 1100 °C
Heating rate0.1–50 °C/min
DetectorTCD, MS optional
Gas lines4–6, MFC controlled
Pulse loop volume0.05–2 mL
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 9277, ISO 15901-2, ISO 15901-3

What is the Chemisorption Analyzer for Catalyst Metal Dispersion and TPR/TPD?

An automated instrument that doses hydrogen, CO or oxygen onto catalysts and uses a thermal conductivity detector with a programmable furnace. It measures active metal surface area, dispersion and acid sites through pulse chemisorption, TPR, TPD and TPO experiments.

What is the Chemisorption Analyzer for Catalyst Metal Dispersion and TPR/TPD?

An automated instrument that doses hydrogen, CO or oxygen onto catalysts and uses a thermal conductivity detector with a programmable furnace. It measures active metal surface area, dispersion and acid sites through pulse chemisorption, TPR, TPD and TPO experiments.

Overview

A chemisorption analyzer uses a flow-through quartz reactor in a programmable furnace that runs from ambient to 1100 °C. A gas manifold with mass flow controllers delivers reducing, oxidizing and probe gases. In pulse mode, calibrated loops inject hydrogen or CO pulses over a pretreated catalyst, and the thermal conductivity detector quantifies the uptake until saturation. Stoichiometry assumptions, such as one hydrogen atom per platinum surface atom, convert the uptake to metal dispersion and surface area. Temperature-programmed reduction tracks reducibility of oxides, temperature-programmed desorption of ammonia or CO2 characterizes acid or basic sites, and oxidation experiments analyze coke. A mass spectrometer or cold trap may be attached to identify evolved species and remove water.

How does it work?

These analyzers expose a degassed solid to an adsorbate and measure how much is taken up. In static volumetric physisorption, known doses of nitrogen, argon or krypton are admitted to a manifold and sample tube at 77 K or 87 K, and the pressure drop after equilibration gives the adsorbed volume. Isotherms are analyzed with BET for surface area, t-plot and DFT methods for micropores, and BJH for mesopores. Gravimetric systems weigh the sample directly while vapor pressure is controlled. Chemisorption analyzers dose hydrogen, CO or oxygen at elevated temperature and use thermal conductivity detection for temperature-programmed reduction and desorption. Key components are vacuum pumps, pressure transducers, a cryogenic bath or furnace, and analysis software.

What are the key features?

  • Quartz U-tube reactor in furnace programmable to 1100 °C
  • Mass flow controlled gas manifold with up to six gas lines
  • Calibrated pulse injection loops for hydrogen, CO and oxygen
  • Thermal conductivity detector with optional mass spectrometer interface
  • Cold trap for water removal during reduction and desorption
  • Automated dispersion, particle size and TPR peak analysis software

What are the technical specifications?

A typical chemisorption analyzer for catalyst metal dispersion and tpr/tpd configuration offers measurement modes of Pulse chemisorption, TPR, TPD, TPO, furnace temperature range of Ambient to 1100 °C, heating rate of 0.1–50 °C/min, detector of TCD, MS optional, gas lines of 4–6, MFC controlled and pulse loop volume of 0.05–2 mL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Chemisorption Analyzer for Catalyst Metal Dispersion and TPR/TPD is used in noble metal dispersion on supports, reducibility screening by H₂-TPR, acid site strength by NH₃-TPD and fuel cell and automotive catalyst development. Across the wider Surface Area Analyzers class, laboratories also deploy it for catalyst and support characterization, battery electrode powder analysis and activated carbon and adsorbent testing.

Which standards and certifications apply?

Relevant standards and methods include ISO 9277, ISO 15901-2, ISO 15901-3, ASTM D3663 and ASTM D4365. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Sample degassing is the main source of error; select temperature and time so that moisture and volatiles are removed without changing the structure, and weigh the sample after degassing. Use adequate sample mass to provide at least 1 m² of total surface area, or 0.05 m² with krypton. Check free-space calibration and leak rates regularly. Ensure a reliable supply of high-purity gases, typically 99.999 percent, and monitor liquid nitrogen levels. Verify performance with certified reference materials of known surface area. Place the unit on a stable bench with ventilation for cryogenic and hydrogen work, and follow local rules for compressed gas cylinders.

How do I select the right Chemisorption Analyzer for Catalyst Metal Dispersion and TPR/TPD?

Select this variant for catalyst development where active metal area, dispersion, reducibility or acidity determines performance. It is not needed for plain surface area measurements. In an RFQ, specify probe gases including any corrosive or toxic ones, maximum temperature, required detector, vapor generator for ammonia or water, and exhaust handling.

How does it compare with other Surface Area Analyzers variants?

Decide first what must be measured. Surface area and mesopore size of powders, catalysts and electrode materials suit a volumetric physisorption analyzer; micropore work requires turbomolecular pumping and low-pressure transducers. Very low area films and substrates need krypton capability. Water or solvent uptake calls for a gravimetric vapor sorption analyzer. Metal dispersion and acid site measurements need a chemisorption system with a furnace and detector. Hydrogen and methane storage research needs a high-pressure sorption analyzer. Compare the number of analysis ports, degassing stations, pressure range, transducer accuracy, liquid nitrogen consumption and compliance with ISO 9277 and ISO 15901-2 when specifying.

Full specifications

Full specifications
Measurement modesPulse chemisorption, TPR, TPD, TPO
Furnace temperature rangeAmbient to 1100 °C
Heating rate0.1–50 °C/min
DetectorTCD, MS optional
Gas lines4–6, MFC controlled
Pulse loop volume0.05–2 mL
Sample mass50–500 mg
Detector sensitivity≥ 0.1 µmol H₂ uptake
Temperature accuracy±1 °C
Flow range5–100 mL/min

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Noble metal dispersion on supports
  • Reducibility screening by H₂-TPR
  • Acid site strength by NH₃-TPD
  • Fuel cell and automotive catalyst development

Key features

  • Quartz U-tube reactor in furnace programmable to 1100 °C
  • Mass flow controlled gas manifold with up to six gas lines
  • Calibrated pulse injection loops for hydrogen, CO and oxygen
  • Thermal conductivity detector with optional mass spectrometer interface
  • Cold trap for water removal during reduction and desorption
  • Automated dispersion, particle size and TPR peak analysis software

Frequently asked questions about Chemisorption Analyzer for Catalyst Metal Dispersion and TPR/TPD

Metal dispersion is the fraction of metal atoms exposed at the surface of catalyst particles, usually calculated from hydrogen or CO chemisorption uptake and an assumed adsorption stoichiometry. High dispersion means small particles and more accessible active sites.

Request a quotation for the Chemisorption Analyzer for Catalyst Metal Dispersion and TPR/TPD

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote