Microvolume Nucleic Acid Spectrophotometer

微量核酸分光光度计

  • SKU SPE-0004
  • Spectrophotometers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Sample volume0.5–2 µL
Wavelength range190–840 nm
Path length0.05–1 mm (automatic)
Wavelength accuracy±1 nm
Absorbance range (10 mm equivalent)0.02–300 A
dsDNA concentration range2–15,000 ng/µL
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <857>, Ph. Eur. 2.2.25, ASTM E275

What is the Microvolume Nucleic Acid Spectrophotometer?

A microvolume nucleic acid spectrophotometer measures 0.5–2 µL samples directly on a pedestal or in a short-path cell without cuvettes. It quantifies DNA, RNA and proteins at 230, 260 and 280 nm and is used in molecular biology laboratories for rapid sample checks.

What is the Microvolume Nucleic Acid Spectrophotometer?

A microvolume nucleic acid spectrophotometer measures 0.5–2 µL samples directly on a pedestal or in a short-path cell without cuvettes. It quantifies DNA, RNA and proteins at 230, 260 and 280 nm and is used in molecular biology laboratories for rapid sample checks.

Overview

The microvolume spectrophotometer forms a liquid column of sample between two optical surfaces held by surface tension, typically with a path length of 0.05–1 mm that is set automatically. Light from a xenon flash lamp passes through the column to a spectrometer with a linear CCD array, so the full 190–840 nm spectrum is captured in a few seconds. Short path lengths allow undiluted nucleic acid concentrations up to 15,000 ng/µL dsDNA without dilution, and the instrument reports A260/A280 and A260/A230 purity ratios. Some models add a conventional cuvette port for low-concentration samples and for bacterial culture OD600. Pedestals are wiped clean with a lint-free tissue between samples, eliminating consumables. The design suits molecular biology, sequencing library preparation, PCR template checks and protein purification monitoring.

How does it work?

A spectrophotometer passes light from a lamp through a monochromator, which selects a narrow wavelength band using a diffraction grating or filter. The band then crosses a sample held in a cuvette, and a detector such as a silicon photodiode or photomultiplier tube records the transmitted intensity. Absorbance is calculated as the negative logarithm of transmittance, and the Beer–Lambert law relates it linearly to analyte concentration within a limited range. Light sources are typically a tungsten-halogen lamp for the visible range and a deuterium lamp for the ultraviolet. Single-beam designs measure reference and sample sequentially, while double-beam designs split the beam to compensate for lamp drift. Reflectance instruments replace the cuvette with an integrating sphere or a fixed 45/0 geometry to capture color data.

What are the key features?

  • Sample volume of 0.5–2 µL preserves precious DNA, RNA and protein extracts.
  • Automatic path length selection avoids dilution for concentrated nucleic acid samples.
  • Full-spectrum 190–840 nm CCD capture in about 3–5 seconds per measurement.
  • Reports A260/A280 and A260/A230 ratios with automatic baseline correction.
  • Optional cuvette port supports OD600 of bacterial cultures.
  • Touchscreen or PC interface exports data in CSV and PDF formats.

What are the technical specifications?

A typical microvolume nucleic acid spectrophotometer configuration offers sample volume of 0.5–2 µL, wavelength range of 190–840 nm, path length of 0.05–1 mm (automatic), wavelength accuracy of ±1 nm, absorbance range (10 mm equivalent) of 0.02–300 A and dsDNA concentration range of 2–15,000 ng/µL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Microvolume Nucleic Acid Spectrophotometer is used in DNA and RNA quantification, NGS library preparation checks, protein A280 measurement and PCR template verification. Across the wider Spectrophotometers class, laboratories also deploy it for nucleic acid and protein quantification, water and environmental colorimetric analysis and pharmaceutical and chemical QC.

Which standards and certifications apply?

Relevant standards and methods include USP <857>, Ph. Eur. 2.2.25, ASTM E275, ASTM E308, JJG 178 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the instrument on a vibration-free bench away from direct sunlight and strong air currents, and allow 15–30 minutes of warm-up for lamp stabilization. Verify wavelength accuracy, photometric accuracy, stray light and baseline noise at defined intervals using certified reference filters or solutions. Keep cuvettes clean, matched and free of scratches, and use quartz cells below 340 nm. Deuterium and tungsten lamps have finite lifetimes, so record lamp hours and schedule replacement. Keep the sample compartment dry and protected from spills. In regulated environments, apply installation, operational and performance qualification and maintain calibration records.

How do I select the right Microvolume Nucleic Acid Spectrophotometer?

Choose a microvolume model when sample volume is limited or concentrations are high. It is not designed for routine analytes in large cuvettes. In an RFQ, specify minimum sample volume, dsDNA range, need for a cuvette port, software outputs and whether surface-tension wipe-clean pedestals are acceptable for your sample types, including volatile solvents.

How does it compare with other Spectrophotometers variants?

Start with the wavelength range: visible-only instruments cover roughly 320–1100 nm and suit colorimetric assays, while UV-capable models extend to 190 nm for nucleic acids, proteins and organic compounds. Next consider photometric stability and stray light, which determine the usable absorbance range; double-beam optics give lower drift for long kinetic runs and method validation. Spectral bandwidth matters for sharp absorption peaks, with 1–2 nm adequate for most quantitative work. Sample volume and format separate standard cuvette models from microvolume and portable designs. Regulated laboratories should check for software audit trails, electronic records support and verification routines. Finally, consider throughput, accessories such as Peltier cell holders or autosamplers, and whether the instrument must operate outside the laboratory.

Full specifications

Full specifications
Sample volume0.5–2 µL
Wavelength range190–840 nm
Path length0.05–1 mm (automatic)
Wavelength accuracy±1 nm
Absorbance range (10 mm equivalent)0.02–300 A
dsDNA concentration range2–15,000 ng/µL
Photometric accuracy±1.5 % at 0.97 A at 257 nm
Measurement time≤5 s
Light sourceXenon flash lamp
Detector2048-element linear CCD array
ConnectivityUSB, Wi-Fi (optional)

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • DNA and RNA quantification
  • NGS library preparation checks
  • Protein A280 measurement
  • PCR template verification

Key features

  • Sample volume of 0.5–2 µL preserves precious DNA, RNA and protein extracts.
  • Automatic path length selection avoids dilution for concentrated nucleic acid samples.
  • Full-spectrum 190–840 nm CCD capture in about 3–5 seconds per measurement.
  • Reports A260/A280 and A260/A230 ratios with automatic baseline correction.
  • Optional cuvette port supports OD600 of bacterial cultures.
  • Touchscreen or PC interface exports data in CSV and PDF formats.

Frequently asked questions about Microvolume Nucleic Acid Spectrophotometer

The A260/A280 ratio estimates protein contamination in a nucleic acid sample. Pure DNA is typically about 1.8 and pure RNA about 2.0. Lower values suggest protein or phenol carryover, although the ratio is affected by pH and ionic strength.