Single-Beam UV-Vis Spectrophotometer
单光束紫外可见分光光度计
- SKU SPE-0002
- Spectrophotometers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Wavelength range | 190–1100 nm |
|---|---|
| Spectral bandwidth | 1 nm or 2 nm |
| Wavelength accuracy | ±0.5 nm |
| Wavelength repeatability | ≤0.2 nm |
| Photometric range | −0.3 to 3.0 A |
| Photometric accuracy | ±0.003 A at 0.5–1 A |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <857>, Ph. Eur. 2.2.25, ASTM E275
What is the Single-Beam UV-Vis Spectrophotometer?
A single-beam UV-Vis spectrophotometer measures absorbance from about 190 to 1100 nm with one optical path, using a deuterium and a tungsten lamp. It provides accurate routine quantitation at moderate cost when a reference is re-zeroed before measurement.
What is the Single-Beam UV-Vis Spectrophotometer?
A single-beam UV-Vis spectrophotometer measures absorbance from about 190 to 1100 nm with one optical path, using a deuterium and a tungsten lamp. It provides accurate routine quantitation at moderate cost when a reference is re-zeroed before measurement.
Overview
The single-beam UV-Vis spectrophotometer directs all light along one path and measures the blank and sample in sequence. A deuterium lamp covers 190–340 nm and a tungsten-halogen lamp covers the visible range, with an automatic lamp switchover near 340–360 nm. A Czerny–Turner or concave holographic grating monochromator provides 1–2 nm bandwidth. Since the blank and sample are not measured simultaneously, the design is more sensitive to lamp drift, so warm-up and frequent re-zeroing are important. Its simpler optics give high throughput and a lower purchase price than double-beam models. Most instruments offer wavelength scanning, time-course and multi-wavelength modes, and a PC or built-in display for methods. The design is widely used for assay work such as protein quantification, enzymatic kinetics at fixed wavelengths and routine chemical QC where the absorbance range stays below about 2 A.
How does it work?
A spectrophotometer passes light from a lamp through a monochromator, which selects a narrow wavelength band using a diffraction grating or filter. The band then crosses a sample held in a cuvette, and a detector such as a silicon photodiode or photomultiplier tube records the transmitted intensity. Absorbance is calculated as the negative logarithm of transmittance, and the Beer–Lambert law relates it linearly to analyte concentration within a limited range. Light sources are typically a tungsten-halogen lamp for the visible range and a deuterium lamp for the ultraviolet. Single-beam designs measure reference and sample sequentially, while double-beam designs split the beam to compensate for lamp drift. Reflectance instruments replace the cuvette with an integrating sphere or a fixed 45/0 geometry to capture color data.
What are the key features?
- Deuterium and tungsten lamps with automatic switchover cover 190–1100 nm.
- Holographic grating monochromator provides 1–2 nm bandwidth with low stray light.
- Wavelength scan, fixed-wavelength, kinetics and multi-wavelength modes are available.
- Automatic blank correction workflow simplifies routine quantitation.
- Four-position or single cell holder accommodates 10 mm quartz and glass cuvettes.
- PC control software exports results in spreadsheet-compatible formats.
What are the technical specifications?
A typical single-beam uv-vis spectrophotometer configuration offers wavelength range of 190–1100 nm, spectral bandwidth of 1 nm or 2 nm, wavelength accuracy of ±0.5 nm, wavelength repeatability of ≤0.2 nm, photometric range of −0.3 to 3.0 A and photometric accuracy of ±0.003 A at 0.5–1 A. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Single-Beam UV-Vis Spectrophotometer is used in protein and nucleic acid assays, routine pharmaceutical QC, environmental chemistry and enzyme kinetics at fixed wavelength. Across the wider Spectrophotometers class, laboratories also deploy it for nucleic acid and protein quantification, water and environmental colorimetric analysis and pharmaceutical and chemical QC.
Which standards and certifications apply?
Relevant standards and methods include USP <857>, Ph. Eur. 2.2.25, ASTM E275, ASTM E308, JJG 178 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the instrument on a vibration-free bench away from direct sunlight and strong air currents, and allow 15–30 minutes of warm-up for lamp stabilization. Verify wavelength accuracy, photometric accuracy, stray light and baseline noise at defined intervals using certified reference filters or solutions. Keep cuvettes clean, matched and free of scratches, and use quartz cells below 340 nm. Deuterium and tungsten lamps have finite lifetimes, so record lamp hours and schedule replacement. Keep the sample compartment dry and protected from spills. In regulated environments, apply installation, operational and performance qualification and maintain calibration records.
How do I select the right Single-Beam UV-Vis Spectrophotometer?
Select the single-beam UV-Vis model for routine quantitation where the absorbance range is moderate and budget matters. Choose double-beam when long scans, low drift or method validation requirements dominate. In an RFQ, state wavelength range, bandwidth, stray-light limit, cell holder type, PC or standalone operation and software compliance features.
How does it compare with other Spectrophotometers variants?
Start with the wavelength range: visible-only instruments cover roughly 320–1100 nm and suit colorimetric assays, while UV-capable models extend to 190 nm for nucleic acids, proteins and organic compounds. Next consider photometric stability and stray light, which determine the usable absorbance range; double-beam optics give lower drift for long kinetic runs and method validation. Spectral bandwidth matters for sharp absorption peaks, with 1–2 nm adequate for most quantitative work. Sample volume and format separate standard cuvette models from microvolume and portable designs. Regulated laboratories should check for software audit trails, electronic records support and verification routines. Finally, consider throughput, accessories such as Peltier cell holders or autosamplers, and whether the instrument must operate outside the laboratory.
Full specifications
| Wavelength range | 190–1100 nm |
|---|---|
| Spectral bandwidth | 1 nm or 2 nm |
| Wavelength accuracy | ±0.5 nm |
| Wavelength repeatability | ≤0.2 nm |
| Photometric range | −0.3 to 3.0 A |
| Photometric accuracy | ±0.003 A at 0.5–1 A |
| Stray light | ≤0.05 %T at 220 nm and 360 nm |
| Baseline stability | ≤0.001 A/h after warm-up |
| Light source | Deuterium lamp and tungsten-halogen lamp |
| Detector | Silicon photodiode |
| Scan speed | Up to 2000 nm/min |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Protein and nucleic acid assays
- Routine pharmaceutical QC
- Environmental chemistry
- Enzyme kinetics at fixed wavelength
Key features
- Deuterium and tungsten lamps with automatic switchover cover 190–1100 nm.
- Holographic grating monochromator provides 1–2 nm bandwidth with low stray light.
- Wavelength scan, fixed-wavelength, kinetics and multi-wavelength modes are available.
- Automatic blank correction workflow simplifies routine quantitation.
- Four-position or single cell holder accommodates 10 mm quartz and glass cuvettes.
- PC control software exports results in spreadsheet-compatible formats.
Frequently asked questions about Single-Beam UV-Vis Spectrophotometer
Yes, for many routine assays. Accuracy depends on warm-up, frequent blank re-zeroing and operating within about 0.1–1.5 A. For regulated assays with long runs, double-beam optics give lower drift and are often preferred.
The changeover between the deuterium and tungsten lamps usually occurs between 340 and 360 nm and can often be set in software. A small step can appear in the baseline there, which is why the change wavelength should be chosen away from sample peaks.
Reliable quantitation is typically achieved between 0.1 and about 1.5 A, where stray light and noise effects are small. Above 2 A, stray light causes negative deviation from the Beer–Lambert law, so samples should be diluted.
A spectrophotometer measures the intensity of light after it passes through or reflects from a sample at specific wavelengths. From this it reports transmittance, absorbance or reflectance, which can be converted to concentration using a calibration curve or to color coordinates such as CIE L*a*b*.
A colorimeter uses fixed filters or LEDs at a few wavelengths, while a spectrophotometer uses a monochromator to scan a continuous range. Spectrophotometers therefore offer higher spectral resolution, full spectra and greater flexibility, whereas colorimeters are simpler and suited to dedicated assays.
Ordinary glass and most plastics absorb strongly below about 340 nm, which would mask the sample signal. Fused quartz transmits down to roughly 190 nm, so it is required for nucleic acid measurements at 260 nm and for UV absorption of organic compounds.
Related models