Near-Infrared Soil Nutrient Analyzer
近红外土壤养分分析仪
- SKU SNA-0004
- Soil Nutrient Analyzers
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement principle | Near-infrared reflectance |
|---|---|
| Wavelength range | 900–2500 nm |
| Predicted properties | Organic matter, total C, total N, texture |
| Measurement time | 30–90 s |
| Sample preparation | Air-dried, ground to 2 mm or finer |
| Calibration | Local spectral library required |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 11261 (total nitrogen), ISO 11263 (phosphorus), ISO 11260 (CEC)
What is the Near-Infrared Soil Nutrient Analyzer?
An instrument that predicts soil organic matter and nutrient indicators from reflectance spectra. It is the right choice for large soil survey programmes that need rapid estimates once local calibrations are established.
What is the Near-Infrared Soil Nutrient Analyzer?
An instrument that predicts soil organic matter and nutrient indicators from reflectance spectra. It is the right choice for large soil survey programmes that need rapid estimates once local calibrations are established.
Overview
The near-infrared soil analyzer measures reflectance from a dried, ground soil sample and applies calibration models to predict organic matter, total carbon and nitrogen, and sometimes texture and available nutrients. Models are built from samples whose values were measured by reference chemistry, so accuracy depends on how well the calibration set represents local soils, parent materials and management. Measurement takes a minute or less and is non-destructive, which is valuable when thousands of samples must be screened, and spectral libraries can be shared and extended over time. Predictions for some properties, such as available phosphorus, are weaker than for organic matter and total carbon, so results are best used for screening, mapping and targeting reference analysis. Sample preparation, moisture and particle size must be controlled, and periodic bias adjustment with reference samples keeps predictions aligned.
How does it work?
Soil nutrient analysis usually begins with extraction, because plant-available nutrients are a small fraction of the total. Available phosphorus is extracted in a bicarbonate or acid solution and measured by the molybdenum blue colorimetric method. Available nitrogen as ammonium and nitrate is extracted in salt solution and measured by indophenol blue or ultraviolet absorption, while total nitrogen uses Kjeldahl digestion or combustion. Potassium is extracted and measured by flame emission or atomic absorption. Automated analyzers perform these steps in continuous flow, mixing sample with reagents in tubing and reading the coloured product in a flow cell, which gives high throughput with low reagent use. Near-infrared instruments predict organic matter and nutrient content from reflectance spectra. Compact field analyzers combine extraction with a simple colorimeter or ion-selective electrode for immediate results.
What are the key features?
- Non-destructive measurement from reflectance spectra.
- Predicts organic matter, total carbon and total nitrogen.
- Measurement in under a minute suits large sample sets.
- Spectral libraries can be extended with local samples.
- Best used for screening and mapping before reference analysis.
- Bias adjustment with reference samples maintains accuracy.
What are the technical specifications?
A typical near-infrared soil nutrient analyzer configuration offers measurement principle of Near-infrared reflectance, wavelength range of 900–2500 nm, predicted properties of Organic matter, total C, total N, texture, measurement time of 30–90 s, sample preparation of Air-dried, ground to 2 mm or finer and calibration of Local spectral library required. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Near-Infrared Soil Nutrient Analyzer is used in large-scale soil surveys, precision agriculture soil mapping, soil carbon monitoring and screening before reference analysis. Across the wider Soil Nutrient Analyzers class, laboratories also deploy it for fertilizer recommendation testing, soil fertility monitoring and precision agriculture management.
Which standards and certifications apply?
Relevant standards and methods include ISO 11261 (total nitrogen), ISO 11263 (phosphorus), ISO 11260 (CEC), ISO 10694 (organic carbon), HJ 634 (ammonium, nitrite and nitrate) and ISO 10390 (pH). Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Use representative, air-dried and sieved samples and record the preparation, because soil test values depend on sampling depth, drying and particle size. Follow the extraction conditions exactly: extractant concentration, soil to solution ratio, shaking time and temperature all change the result. Run blanks and certified reference soil with each batch, and check calibration curves daily for colorimetric methods. For continuous flow systems, maintain tubing, lamps and flow rates, and check for carry-over between samples. Keep reagents fresh and store them as the method requires, and neutralise or dispose of acid and heavy-metal waste properly. Calibrate balances and check the spectrometer wavelength accuracy. Document method, units and reporting basis so results can be compared over time and between laboratories.
How do I select the right Near-Infrared Soil Nutrient Analyzer?
Select the near-infrared analyzer for high-volume screening and mapping where approximate values are useful and a local calibration library can be maintained. For reported values, use reference chemistry. In an RFQ, specify the properties of interest, sample preparation and whether a calibration library is included.
How does it compare with other Soil Nutrient Analyzers variants?
Decide first whether the requirement is available nutrients for fertilizer recommendations, total content for nutrient budgeting, or rapid field estimates. For official recommendations, use the extraction and measurement methods prescribed by the local soil testing service, because calibrations between soil test values and crop response are tied to a specific method. Continuous flow and discrete analyzers give high throughput and good precision for routine laboratory work, while a manual spectrophotometer suits low volumes. Kjeldahl or combustion nitrogen analyzers are chosen when total nitrogen is required. Near-infrared is attractive for large sample numbers once calibrated locally, but it needs reference data. Compact field analyzers are useful for immediate guidance but have wider uncertainty. Consider digestion and extraction safety, reagent and waste handling, the sample preparation needed, and compatibility with laboratory information systems.
Full specifications
| Measurement principle | Near-infrared reflectance |
|---|---|
| Wavelength range | 900–2500 nm |
| Predicted properties | Organic matter, total C, total N, texture |
| Measurement time | 30–90 s |
| Sample preparation | Air-dried, ground to 2 mm or finer |
| Calibration | Local spectral library required |
| Accuracy | Property dependent, best for organic matter |
| Outputs | USB, Ethernet, LIMS export |
| Power supply | 220 VAC, 50 Hz or battery |
| Operating temperature | 10–35 °C |
| Weight | 5–20 kg |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Large-scale soil surveys
- Precision agriculture soil mapping
- Soil carbon monitoring
- Screening before reference analysis
Key features
- Non-destructive measurement from reflectance spectra.
- Predicts organic matter, total carbon and total nitrogen.
- Measurement in under a minute suits large sample sets.
- Spectral libraries can be extended with local samples.
- Best used for screening and mapping before reference analysis.
- Bias adjustment with reference samples maintains accuracy.
Frequently asked questions about Near-Infrared Soil Nutrient Analyzer
Organic matter, total carbon and total nitrogen are predicted most reliably because they relate to spectrally active organic bonds. Texture and some exchange properties are predicted moderately, while available phosphorus and nitrate are weaker and usually need reference analysis.
Soil mineralogy, colour and organic matter type vary by region, so a model built elsewhere predicts poorly. Collecting local samples with reference analyses builds a library that matches the soils being measured, and it can be extended each year.
Yes, water absorbs near-infrared light strongly, so samples are air-dried to a consistent state and ground to a uniform size. Measuring moist samples without a matching calibration gives unreliable results.
Available nutrients are the fraction a plant can take up in the short term and are measured after extraction, so they guide fertilizer rates. Total nutrients include mineral and organic forms and are used for nutrient budgets, not for immediate recommendation.
Different extractants and ratios dissolve different amounts of nutrient, so values are only comparable within one method. The calibration between soil test value and crop response is also method specific, so changing methods invalidates the interpretation.
Samples are air-dried at a moderate temperature, ground and passed through a two-millimetre sieve, with stones and roots removed. Drying and grinding affect extractability, so the same preparation is used for all samples in a comparison.