Microwave Digestion System for Industrial Samples
工业样品微波消解系统
- SKU SAT-0006
- Sample Preparation
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Vessel volume | 55–100 mL |
|---|---|
| Max temperature | Up to 240 °C |
| Max pressure | Up to 80 bar |
| Batch size | 8–40 vessels |
| Microwave power | 1000–1600 W |
| Temperature control | Infrared sensor or fibre-optic probe |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 3082, ASTM D2013, ASTM E877
What is the Microwave Digestion System for Industrial Samples?
A microwave digestion system dissolves industrial samples in acid inside sealed vessels at elevated temperature and pressure, producing a clear solution for ICP-OES, ICP-MS or atomic absorption. It is the best choice when trace metals are required at low detection limits and fusion dilution would lose sensitivity.
What is the Microwave Digestion System for Industrial Samples?
A microwave digestion system dissolves industrial samples in acid inside sealed vessels at elevated temperature and pressure, producing a clear solution for ICP-OES, ICP-MS or atomic absorption. It is the best choice when trace metals are required at low detection limits and fusion dilution would lose sensitivity.
Overview
Microwave digestion uses 2.45 GHz microwave energy absorbed by the acid mixture to heat the sample rapidly and uniformly inside sealed, chemically inert vessels. Because the vessels are closed, the acid boils above its atmospheric boiling point, typically reaching 180–240 °C and 20–80 bar, which accelerates decomposition of silicates, sulfides, alloys and polymers. Rotors carry eight to forty vessels so a batch is digested together under identical conditions. Temperature is usually measured by an infrared sensor under the rotor or by a fibre-optic probe in a reference vessel, and pressure can be monitored in the same reference vessel, which produces reproducible extraction of the target elements. After cooling, digests are diluted to volume and measured, with reagent blanks and certified reference materials run in each batch.
How does it work?
Industrial sample preparation reduces a bulk lot to a small test portion without changing its composition. Crushing and milling lower particle size by compressive, impact or shear forces, and representative splitting follows each size-reduction step so the sub-sample still reflects the original lot. Disc mills and ring mills grind to below 75 µm for pressed pellets or fusion, where the sample is melted with a borate flux to dissolve refractory minerals into a homogeneous glass bead. Microwave digestion dissolves samples in acid at elevated temperature and pressure in closed vessels for ICP or atomic absorption measurement. Throughout, materials that touch the sample are chosen to avoid contamination: tungsten carbide for hard ores, zirconia for trace-element work, agate for soft or brittle materials.
What are the key features?
- Sealed vessels reaching up to 240 °C and 80 bar
- Rotor configurations for 8 to 40 vessels
- Contact-free infrared or fibre-optic temperature control
- Programmable multi-stage heating ramps
- PTFE and PFA wetted parts for HF and HNO3 service
- Exhaust and venting system for acid vapours
What are the technical specifications?
A typical microwave digestion system for industrial samples configuration offers vessel volume of 55–100 mL, max temperature of Up to 240 °C, max pressure of Up to 80 bar, batch size of 8–40 vessels, microwave power of 1000–1600 W and temperature control of Infrared sensor or fibre-optic probe. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Microwave Digestion System for Industrial Samples is used in trace-metal analysis of ores and concentrates by ICP, ferroalloy and steel dissolution for process control, polymer and additive elemental analysis, catalyst and pigment metal content determination and roHS and heavy-metal compliance testing. Across the wider Sample Preparation class, laboratories also deploy it for ore and concentrate assay laboratories, cement, clinker and raw meal quality control and coal and coke sample preparation for ash and sulfur analysis.
Which standards and certifications apply?
Relevant standards and methods include ISO 3082, ASTM D2013, ASTM E877, ISO 3310-1, ISO 2758 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install crushing and milling equipment on a rigid floor with dust extraction and hearing protection, because noise commonly exceeds 80 dB(A). Sieve checks and, for trace analysis, blank grinds with quartz sand keep cross-contamination low; grinding sets wear and should be inspected for cracks. Verify press force and die condition at intervals, and re-check pellet quality after any change of powder supplier. Crucibles, dies and digestion vessels are consumables that must meet the method's contamination specification. Balance calibration, temperature records and traceable reference materials support method validation and laboratory accreditation.
How do I select the right Microwave Digestion System for Industrial Samples?
Choose microwave digestion when the required detection limits are lower than fusion dilution allows, or when the sample set is dominated by polymers, catalysts and alloys rather than refractory oxides. Specify vessel count from the daily batch, vessel chemistry from the acid programme, and whether HF-resistant vessels are needed for silicate work. Confirm the temperature and pressure ratings you actually require, and plan a fume hood or ducted extraction, since digestion releases acid vapours on opening.
How does it compare with other Sample Preparation variants?
Choose by the physical form of the material and the analytical technique that follows. Hard, brittle ores, clinker and ferroalloys need a jaw crusher for primary reduction, then a disc or ring mill for fine grinding; soft polymers and coal may need only a cutting mill. Fusion bead preparation is required when the sample is measured by XRF or ICP and total dissolution is difficult, while pressed pellets are faster and cheaper when only major oxides are sought. Microwave digestion is the quickest route to a clear solution for trace-metal measurement. Specify final particle size, contamination limits for the elements of interest, batch size per shift, cleaning between samples, and whether a method standard demands a defined splitting scheme.
Full specifications
| Vessel volume | 55–100 mL |
|---|---|
| Max temperature | Up to 240 °C |
| Max pressure | Up to 80 bar |
| Batch size | 8–40 vessels |
| Microwave power | 1000–1600 W |
| Temperature control | Infrared sensor or fibre-optic probe |
| Pressure monitoring | Reference vessel, non-contact |
| Wetted materials | PTFE, PFA, quartz |
| Typical digestion time | 20–45 min including cooling |
| Ventilation requirement | Ducted fume extraction |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Trace-metal analysis of ores and concentrates by ICP
- Ferroalloy and steel dissolution for process control
- Polymer and additive elemental analysis
- Catalyst and pigment metal content determination
- RoHS and heavy-metal compliance testing
Key features
- Sealed vessels reaching up to 240 °C and 80 bar
- Rotor configurations for 8 to 40 vessels
- Contact-free infrared or fibre-optic temperature control
- Programmable multi-stage heating ramps
- PTFE and PFA wetted parts for HF and HNO3 service
- Exhaust and venting system for acid vapours
Frequently asked questions about Microwave Digestion System for Industrial Samples
Nitric acid is the base for most industrial work, often with hydrochloric acid for alloys and sulfides. Hydrofluoric acid is added for silicates and refractory oxides, requiring HF-resistant vessels and a borate complexation step before ICP. Sulfuric and perchloric acid are avoided in sealed vessels because of pressure and safety concerns.
The digest should be a clear, particle-free solution after dilution; any residue suggests incomplete decomposition, insufficient acid or too short a hold. Laboratories verify completeness with a certified reference material recovered at 90–110% of the certified value, run in the same batch and with the same programme.
After digestion the vessel contains acid vapour at tens of bar and over 200 °C. Opening a hot vessel releases that vapour abruptly, which can spray hot acid and lose volatile analytes such as mercury and arsenic. Programmes therefore include a controlled cooling stage, and vessels are vented slowly in a fume hood.
A test portion of a few grams must represent a lot of many tonnes, so any inhomogeneity, particle-size effect or contamination introduced during crushing, splitting or grinding is carried into the result. Sampling and preparation errors are added to, not averaged out by, the measurement, which makes a documented, repeatable procedure essential.
Fusion beads suit refractory or mineralogically complex materials such as ores, cement and ceramic powders, because the borate flux dissolves the sample and removes particle-size and mineralogy effects. Pressed pellets are adequate for routine major-oxide screening, are much faster, and avoid the platinum crucibles, flux and high-temperature furnace that fusion requires.
Between samples, grind a quartz sand or pure material blank and discard it, then brush and if permitted wipe the grinding set. Match the grinding material to the elements of interest: tungsten carbide adds cobalt and tungsten, steel adds iron and chromium, and agate or zirconia is preferred for trace analysis. Sieving the ground powder checks that the target fineness was reached.