Digital Rocking Shaker
数字摇摆摇床
- SKU ROS-0003
- Rocking Shakers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Platform size | 250×250 to 400×400 mm |
|---|---|
| Tilt angle | 3–15 degrees, set or adjustable |
| Speed range | 5–80 tilts/min |
| Load rating | 2–8 kg |
| Speed resolution | 1 tilt/min |
| Timer range | 1 min to 999 h |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-051, ISO 9001
What is the Digital Rocking Shaker?
A digital rocking shaker sets and holds tilt and speed precisely with a microprocessor controller. It is chosen when rocking methods must be reproduced exactly and documented consistently between runs and operators.
What is the Digital Rocking Shaker?
A digital rocking shaker sets and holds tilt and speed precisely with a microprocessor controller. It is chosen when rocking methods must be reproduced exactly and documented consistently between runs and operators.
Overview
The digital rocker replaces analog controls with a microprocessor that sets speed to 1 tilt per minute and time precisely, holding speed by closed-loop control. Some models also set tilt digitally or store several programs with different tilt and speed steps. The display shows speed and remaining time, and accumulated run time is available for maintenance. Soft start reduces disturbance when the platform begins to move. Platforms of 250 to 400 mm carry 2 to 8 kg, with rubber mats or clips for trays and frames. Alarms warn of overload or deviation. It suits methods transferred between laboratories, regulated staining protocols and any procedure where a gentle rocking action must be applied consistently.
How does it work?
A rocking shaker pivots the platform about a central axis, so one end rises while the other falls, and the motion reverses each cycle. The drive is a motor turning a cam or crank that lifts the platform on alternating sides, and the tilt angle, usually 3 to 15 degrees, sets how far liquid flows each way. Because the movement is slow and symmetrical, shear is low and liquid spreads evenly over membranes, gels and slides without foaming or splashing. Speed is set in tilts per minute, from about 5 to 80, and rubber mats or dimpled platforms keep items from sliding. The gentle action suits fragile membranes and antibody incubations, and the open platform allows trays, gel frames and boxes to be placed directly. Timers and, on some models, programmable tilt and speed improve reproducibility.
What are the key features?
- Microprocessor control with 1 tilt/min resolution
- Closed-loop speed and time setting
- Program storage, including tilt on some models
- Soft start to reduce disturbance
- Overload and deviation alarms
- Digital display of speed and time
What are the technical specifications?
A typical digital rocking shaker configuration offers platform size of 250×250 to 400×400 mm, tilt angle of 3–15 degrees, set or adjustable, speed range of 5–80 tilts/min, load rating of 2–8 kg, speed resolution of 1 tilt/min and timer range of 1 min to 999 h. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Digital Rocking Shaker is used in reproducible staining protocols, method transfer between laboratories, timed blotting incubations and automated multi-step rocking. Across the wider Rocking Shakers class, laboratories also deploy it for gel staining and destaining, western and Southern blotting and antibody and probe incubation.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-051 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the unit on a level, stable surface with clearance for the tilting platform, and use the rubber mat or clips so membranes, gels and boxes do not slide. Load items evenly around the axis so the drive is not strained, and stay within the load rating. For blotting and antibody work, use enough solution to keep the membrane wet but not so much that it floats off. Clean spills promptly and rinse trays to prevent residue that could contaminate later experiments. Check the pivot, cam and belt for wear on schedule, and confirm that the materials suit the solutions and temperatures used, especially in cold rooms.
How do I select the right Digital Rocking Shaker?
Select the digital rocker when reproducible tilt, speed and timing matter, or when methods must be transferred between sites. Analog models are cheaper for routine staining. In the RFQ, specify tilt range, speed range and resolution, programs, alarms and platform size.
How does it compare with other Rocking Shakers variants?
Choose a rocking shaker when gentle, low-shear movement is needed, as for gel staining, membrane washing, blotting and antibody incubation, where orbital or reciprocal motion could damage the substrate or cause foaming. Set the tilt angle from the task, using 3 to 8 degrees for membranes and slides and 8 to 15 degrees for mixing larger volumes. Match the platform size and mat to the trays, frames or boxes you will place on it, and confirm the load rating. Decide whether a fixed or adjustable tilt is needed, and whether a timer, digital control or dual platform improves your workflow. Confirm that the unit suits the temperature, such as a cold room, where it will be used.
Full specifications
| Platform size | 250×250 to 400×400 mm |
|---|---|
| Tilt angle | 3–15 degrees, set or adjustable |
| Speed range | 5–80 tilts/min |
| Load rating | 2–8 kg |
| Speed resolution | 1 tilt/min |
| Timer range | 1 min to 999 h |
| Programs | Up to 5 multi-step |
| Alarms | Overload and deviation |
| Soft start | Standard |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Reproducible staining protocols
- Method transfer between laboratories
- Timed blotting incubations
- Automated multi-step rocking
Key features
- Microprocessor control with 1 tilt/min resolution
- Closed-loop speed and time setting
- Program storage, including tilt on some models
- Soft start to reduce disturbance
- Overload and deviation alarms
- Digital display of speed and time
Frequently asked questions about Digital Rocking Shaker
It sets speed precisely and holds it with feedback, displays speed and time, and on some models stores programs and controls tilt digitally. This improves reproducibility and makes methods easier to document and transfer than analog knob control.
Some models store up to five multi-step programs with different speeds, times and, where fitted, tilt settings. Programs are named or numbered and can be repeated, giving consistent staining and blotting results across runs and operators.
Soft start brings the platform up to speed gradually, so liquid on a membrane is not suddenly pushed to one side and small items do not slide. It is especially useful when trays are filled close to the top or items are not clamped.
It gently tilts a platform so liquid moves back and forth over a membrane, gel or sample. Typical uses are gel staining, blotting, antibody incubation, membrane washing and blood mixing, where low shear and even wetting matter more than vigorous agitation.
Use 3 to 8 degrees for membranes, gels and slides, where gentle flow prevents damage, and 8 to 15 degrees when mixing larger volumes or thicker samples. Higher angles move liquid further but can wash small items off the platform.
Most run 5 to 80 tilts per minute. Slow speeds suit antibody incubation and fragile membranes, while faster speeds mix solutions more quickly. The method usually specifies the setting, and gentle speeds are preferred for long incubations.