Online Dissolved Oxygen Analyzer
在线溶解氧分析仪
- SKU PRC-0003
- Process Analyzers
- CE (to be confirmed)
- ATEX/IECEx for hazardous area versions (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measuring range | 0–20 mg/L (0–200 % sat.) |
|---|---|
| Trace range option | 0–2000 μg/L |
| Accuracy | ±0.1 mg/L or ±1 % of reading |
| Resolution | 0.01 mg/L (1 μg/L trace) |
| Response time (T90) | <60 s |
| Process temperature | 0–50 °C (up to 130 °C option) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 9001, IEC 61010-1, IEC 60079-0
What is the Online Dissolved Oxygen Analyzer?
An analyzer with an optical luminescence or amperometric sensor that continuously measures dissolved oxygen in water or process liquids. It is the right choice for aeration control, boiler feedwater, fermentation and oxygen-sensitive beverage production.
What is the Online Dissolved Oxygen Analyzer?
An analyzer with an optical luminescence or amperometric sensor that continuously measures dissolved oxygen in water or process liquids. It is the right choice for aeration control, boiler feedwater, fermentation and oxygen-sensitive beverage production.
Overview
An online dissolved oxygen analyzer uses either an optical luminescence sensor or a membrane-covered amperometric sensor. In optical sensors, a blue LED excites a luminophore in a sensing cap, and dissolved oxygen quenches the red emission in proportion to its partial pressure; the lifetime of the luminescence is measured, so there is no oxygen consumption, no electrolyte and low maintenance. Amperometric Clark-type sensors reduce oxygen at a cathode behind a gas-permeable membrane and measure current. Measurement ranges run from 0.001 to 20 mg/L, with trace versions down to 1 microgram per liter for boiler feedwater and beverage deaeration. Temperature and salinity compensation are applied. Sensor caps typically need replacement every one to two years, and calibration is performed in air-saturated water or water-saturated air.
How does it work?
Process analyzers replace manual sampling with automated measurement at or near the point of production. In-line sensors, such as pH or conductivity electrodes, sit in the pipe or tank. At-line and on-line systems draw a conditioned sample through a flow cell, filter and pressure regulator to a measuring module. Measurement techniques include potentiometry for pH, conductometry for ionic strength, optical luminescence or amperometry for dissolved oxygen, near-infrared spectroscopy with chemometric models for composition, and high-temperature oxidation with infrared detection for organic carbon. A transmitter digitizes the signal, applies temperature compensation and outputs 4 to 20 mA, Modbus, HART or Profibus to a PLC or DCS. Reliability depends on representative sampling, sensor cleaning, calibration and a validated relationship between analyzer and laboratory reference results.
What are the key features?
- Optical luminescence lifetime sensing avoids oxygen consumption and flow dependency.
- No electrolyte or membrane polishing is needed, reducing routine maintenance.
- Trace range versions measure to 1 μg/L for boiler feedwater and deaeration.
- Automatic temperature, salinity and pressure compensation improves accuracy in process use.
- Sensor caps are replaceable in minutes without recalibrating the transmitter electronics.
- Digital output with Modbus or 4–20 mA integrates with aeration and dosing control.
What are the technical specifications?
A typical online dissolved oxygen analyzer configuration offers measuring range of 0–20 mg/L (0–200 % sat.), trace range option of 0–2000 μg/L, accuracy of ±0.1 mg/L or ±1 % of reading, resolution of 0.01 mg/L (1 μg/L trace), response time (T90) of <60 s and process temperature of 0–50 °C (up to 130 °C option). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Online Dissolved Oxygen Analyzer is used in aeration basin control in wastewater plants, boiler feedwater deaeration, fermentation and brewing and aquaculture water monitoring. Across the wider Process Analyzers class, laboratories also deploy it for chemical reactor and neutralization control, boiler and cooling water monitoring and pharmaceutical and food fermentation control.
Which standards and certifications apply?
Relevant standards and methods include ISO 9001, IEC 61010-1, IEC 60079-0, ISO 10523, ISO 7888, ISO 8245, ASTM D1125 and ASTM E1655. Certification candidates for this model are CE, ATEX/IECEx for hazardous area versions and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install sensors where the sample is representative and flow is continuous, avoiding dead legs, air pockets and stagnant zones. Provide isolation valves or retractable assemblies so sensors can be removed without stopping the process. Calibrate against certified buffers or standards at defined intervals and compare periodically with laboratory results. Cleaning frequency depends on fouling; automatic jet or ultrasonic cleaning reduces manual work. In hazardous areas, select equipment certified to the local explosion protection scheme. Keep spare sensors, reagents and filters on site. Document alarm limits, maintenance tasks and the action to be taken when the analyzer fails, because automatic control loops depend on its signal.
How do I select the right Online Dissolved Oxygen Analyzer?
Choose optical sensors for most applications due to low maintenance and drift. Choose trace amperometric sensors for boiler feedwater at microgram per liter levels. In an RFQ specify range, accuracy at the operating concentration, process temperature and pressure, mounting style, cleaning needs and whether sanitary connections or CIP compatibility are required.
How does it compare with other Process Analyzers variants?
Start with the variable that controls product quality or compliance and the response time needed. For ionic or acid-base control, pH and conductivity analyzers are the usual choice. For oxygen-sensitive processes, choose dissolved oxygen. For multi-component composition in real time, near-infrared with a calibrated model fits, while organic contamination in water is measured with TOC. Evaluate process conditions including temperature, pressure, fouling tendency, hazardous area classification and sample conditioning requirements. Compare accuracy, drift, calibration interval, maintenance effort, output protocols and alarm functions. Insertion or flow cell mounting, retractable housings and automatic cleaning matter in dirty streams. Plan a correlation study with laboratory methods before relying on analyzer values for control or release.
Full specifications
| Measuring range | 0–20 mg/L (0–200 % sat.) |
|---|---|
| Trace range option | 0–2000 μg/L |
| Accuracy | ±0.1 mg/L or ±1 % of reading |
| Resolution | 0.01 mg/L (1 μg/L trace) |
| Response time (T90) | <60 s |
| Process temperature | 0–50 °C (up to 130 °C option) |
| Pressure rating | Up to 10 bar |
| Sensor cap life | ≈12–24 months |
| Outputs | 4–20 mA, Modbus RTU |
| Ingress protection | IP68 sensor, IP66 transmitter |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Aeration basin control in wastewater plants
- Boiler feedwater deaeration
- Fermentation and brewing
- Aquaculture water monitoring
Key features
- Optical luminescence lifetime sensing avoids oxygen consumption and flow dependency.
- No electrolyte or membrane polishing is needed, reducing routine maintenance.
- Trace range versions measure to 1 μg/L for boiler feedwater and deaeration.
- Automatic temperature, salinity and pressure compensation improves accuracy in process use.
- Sensor caps are replaceable in minutes without recalibrating the transmitter electronics.
- Digital output with Modbus or 4–20 mA integrates with aeration and dosing control.
Frequently asked questions about Online Dissolved Oxygen Analyzer
Optical sensors consume no oxygen, need no electrolyte or membrane, show less drift and do not depend on flow. They require only periodic cap replacement, which lowers maintenance compared with amperometric sensors.
A one-point calibration in water-saturated air or air-saturated water is common, using measured barometric pressure and temperature. A zero check in a sodium sulfite solution may be added for trace measurements.
Oxygen level controls microbial activity in aeration and fermentation, causes corrosion in boilers and oxidizes flavors and products in food and beverages. Continuous monitoring lets the process keep concentration inside a target window.
Process analyzers are instruments installed in or beside a production line that measure composition or properties automatically and continuously, sending values to a control system. They replace or supplement manual laboratory sampling.
In-line sensors measure directly in the process stream. On-line analyzers automatically divert a sample to an instrument and may return it. At-line analyzers are placed near the process but are operated manually with samples taken by an operator.
It depends on the technology and application. pH sensors are commonly checked weekly or monthly, while optical and NIR analyzers may be verified less often. The interval should be set by drift history and the risk of a wrong reading.
Related models