Pyrolysis GC-MS System for Plastic Composition Analysis

塑料组成分析用裂解气质联用仪

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Pyrolysis temperature400–800 °C, programmable
Pyrolysis modesFlash and programmed
Sample mass0.1–2 mg
Column typeCapillary, 30 m, 5% phenyl phase
GC oven temperatureAmbient to 350 °C with programming
Mass rangem/z 10–500
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 3451-1, ASTM D5630, ASTM D1603

What is the Pyrolysis GC-MS System for Plastic Composition Analysis?

A pyrolysis GC-MS system thermally fragments a plastic sample and separates the fragments by gas chromatography with mass spectrometric detection. It identifies polymer type, plasticisers, stabilisers and flame retardants, including additives that infrared cannot resolve.

What is the Pyrolysis GC-MS System for Plastic Composition Analysis?

A pyrolysis GC-MS system thermally fragments a plastic sample and separates the fragments by gas chromatography with mass spectrometric detection. It identifies polymer type, plasticisers, stabilisers and flame retardants, including additives that infrared cannot resolve.

Overview

A small sample is dropped into a heated pyrolysis probe or furnace held between about 400 and 800 °C, where covalent bonds break reproducibly and the resulting fragments are swept by carrier gas onto a gas chromatography column. Separation is followed by mass spectrometric detection, and the resulting pattern of fragment masses is compared with reference libraries to identify the polymer and any additive present. Because the technique responds to the actual molecules released, it distinguishes copolymers and blends that give similar infrared spectra, and it can detect plasticiser or flame retardant species at low concentration in a filled compound. Programmed pyrolysis, evolved gas analysis and reactive pyrolysis variants extend the range, and quantitative work relies on calibration with known standards of the target additive.

How does it work?

Different questions require different physical principles. Ashing and combustion methods remove the organic matrix by heating in air or oxygen, leaving the inorganic filler or ash as a residue that is weighed, which quantifies mineral content and glass fibre. Carbon black is measured by pyrolysing the polymer in nitrogen and then burning the carbon in oxygen. Infrared spectrometry identifies the polymer and detects functional-group changes caused by oxidation or additives. X-ray fluorescence excites the sample with X-rays and records the emitted characteristic radiation, giving rapid elemental screening for restricted substances. Pyrolysis gas chromatography with mass spectrometry thermally fragments the polymer in an inert atmosphere and separates the fragments, which identifies copolymers, plasticisers and additives that spectroscopy alone cannot resolve.

What are the key features?

  • Pyrolysis temperature range from 400 to 800 °C
  • Capillary GC column with temperature programming
  • Mass spectrometric detection with library search
  • Programmed and single-shot pyrolysis modes
  • Carrier gas control for reproducible fragmentation
  • Calibration for quantitative additive determination

What are the technical specifications?

A typical pyrolysis gc-ms system for plastic composition analysis configuration offers pyrolysis temperature of 400–800 °C, programmable, pyrolysis modes of Flash and programmed, sample mass of 0.1–2 mg, column type of Capillary, 30 m, 5% phenyl phase, GC oven temperature of Ambient to 350 °C with programming and mass range of m/z 10–500. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Pyrolysis GC-MS System for Plastic Composition Analysis is used in identification of copolymers and blends, plasticiser and flame retardant identification, contamination and odour source investigation and verification of recycled plastic additives. Across the wider Plastic Composition Analysis class, laboratories also deploy it for filler and glass fibre content determination, carbon black content in pipe and cable compounds and polymer identification in incoming inspection.

Which standards and certifications apply?

Relevant standards and methods include ISO 3451-1, ASTM D5630, ASTM D1603, ASTM E1131, ASTM D5576, ASTM D3452, ASTM F2617 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Representative sampling matters more than instrument precision, because fillers and additives are rarely distributed perfectly evenly. Grind or cryo-mill specimens, or take several portions from different locations, and record the sampling plan. Control the ashing temperature and time exactly, since mineral fillers may lose mass at high temperature and glass fibre can sinter. Keep crucibles clean and run a blank. For X-ray fluorescence, check the measurement area against the sample size and confirm whether the result reflects the surface layer only. Calibrate all equipment with certified reference materials and retain the raw data with the report.

How do I select the right Pyrolysis GC-MS System for Plastic Composition Analysis?

Specify pyrolysis GC-MS when identification of specific additives or copolymer composition is the objective, and infrared or ash methods have been exhausted. Confirm the pyrolysis modes you need, the mass range for any volatile additives, and whether the supplied library covers your classes of compounds. Quantitative work requires standards, so budget for reference materials of the additives of interest.

How does it compare with other Plastic Composition Analysis variants?

Choose by the question and the number of samples. Filler or glass content is measured by ashing in a muffle furnace or by thermogravimetry, and carbon black by a dedicated tube furnace with controlled atmospheres. Polymer identification is fastest by infrared, while X-ray fluorescence gives the quickest elemental screen for compliance work and can be used on a whole part without preparation. Pyrolysis gas chromatography is reserved for cases where the polymer or additive must be identified rather than quantified quickly, for example in a competitor product study or in a contamination investigation. For surface-specific questions such as filler dispersion or the composition of a single particle, microscopy with elemental analysis is added.

Full specifications

Full specifications
Pyrolysis temperature400–800 °C, programmable
Pyrolysis modesFlash and programmed
Sample mass0.1–2 mg
Column typeCapillary, 30 m, 5% phenyl phase
GC oven temperatureAmbient to 350 °C with programming
Mass rangem/z 10–500
Carrier gasHelium, ≥ 99.999%
DetectorElectron ionisation quadrupole
Power supply220 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Identification of copolymers and blends
  • Plasticiser and flame retardant identification
  • Contamination and odour source investigation
  • Verification of recycled plastic additives

Key features

  • Pyrolysis temperature range from 400 to 800 °C
  • Capillary GC column with temperature programming
  • Mass spectrometric detection with library search
  • Programmed and single-shot pyrolysis modes
  • Carrier gas control for reproducible fragmentation
  • Calibration for quantitative additive determination

Frequently asked questions about Pyrolysis GC-MS System for Plastic Composition Analysis

Heating breaks the polymer into characteristic fragments, and the chromatographic retention times and mass spectra of those fragments form a reproducible pattern. Comparing the pattern with reference data identifies the polymer, and because the fragments reflect the monomer units, copolymers and blends can be distinguished more reliably than by infrared.

Request a quotation for the Pyrolysis GC-MS System for Plastic Composition Analysis