Benchtop ORP/pH Meter
台式 ORP/pH 计
- SKU ORM-0001
- ORP Meters
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| mV range | ±1999.9 mV |
|---|---|
| mV resolution | 0.1 mV |
| mV accuracy | ±0.2 mV |
| pH range | −2.000 to 20.000 pH |
| pH accuracy | ±0.002 pH |
| Temperature range | −5 to 105 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D1498, ISO 11271, DIN 38404-6
What is the Benchtop ORP/pH Meter?
A benchtop ORP/pH meter is a laboratory instrument that reads millivolts with 0.1 mV resolution and also measures pH. It includes relative mV mode, temperature compensation and calibration logs, making it suitable for redox research, titration-supporting measurements and water-quality laboratories.
What is the Benchtop ORP/pH Meter?
A benchtop ORP/pH meter is a laboratory instrument that reads millivolts with 0.1 mV resolution and also measures pH. It includes relative mV mode, temperature compensation and calibration logs, making it suitable for redox research, titration-supporting measurements and water-quality laboratories.
Overview
The benchtop instrument combines a precise millivolt input, typically ±1999.9 mV with 0.1 mV resolution and ±0.2 mV accuracy, with a full pH channel. It allows absolute and relative mV readings, where a stable baseline can be zeroed to follow changes during a reaction. A temperature input supports reporting ORP with correction to the standard hydrogen electrode scale. Data logging shows readings versus time for redox titration support or monitoring of biological and chemical processes. Stability criteria can be chosen so that the instrument only accepts a reading when drift is below a set limit. GLP records and export by USB are standard. Laboratories use it for soil and sediment studies, electroplating baths, food oxidation research and quality control of disinfectants. Electrodes can be combination platinum or gold types with Ag/AgCl reference and the meter supports two-channel use with a pH electrode.
How does it work?
An ORP electrode has an inert metal surface, usually platinum or gold, that does not take part in a reaction but exchanges electrons with redox species in solution. The potential established at the surface reflects the ratio of oxidized to reduced species and is described by the Nernst equation. It is measured against a reference electrode such as silver/silver chloride in potassium chloride and reported in millivolts, either versus the reference or converted to the standard hydrogen electrode scale by adding a temperature-dependent offset of about 200 to 210 mV for Ag/AgCl with 3 mol/L KCl. The meter is a high-impedance millivolt meter, essentially a pH meter in mV mode. ORP is a mixed potential, so it is not specific to a single species and depends on pH, temperature and electrode condition. Typical readings range from minus 500 to plus 1000 mV, with 650 to 750 mV commonly used for disinfected water.
What are the key features?
- mV resolution of 0.1 mV with ±0.2 mV accuracy over a ±1999.9 mV range
- Absolute and relative mV modes for following changes during reactions
- Standard hydrogen electrode conversion using temperature input
- Drift-based stability criteria before a reading is accepted
- Time-based data logging and graph display for redox processes
- Dual-channel capability with simultaneous pH and ORP measurement
What are the technical specifications?
A typical benchtop orp/ph meter configuration offers mV range of ±1999.9 mV, mV resolution of 0.1 mV, mV accuracy of ±0.2 mV, pH range of −2.000 to 20.000 pH, pH accuracy of ±0.002 pH and temperature range of −5 to 105 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop ORP/pH Meter is used in redox research and method development, soil and sediment studies, electroplating bath monitoring, disinfectant QC and food oxidation studies. Across the wider ORP Meters class, laboratories also deploy it for swimming pool and spa disinfection control, wastewater redox treatment and aquaculture and aquarium monitoring.
Which standards and certifications apply?
Relevant standards and methods include ASTM D1498, ISO 11271, DIN 38404-6, GB/T 6920, IEC 60746-2 and APHA 2580. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
ORP electrodes cannot be calibrated like pH electrodes. Verify them against a redox standard such as Zobell's solution (about 228 mV at 25 degrees Celsius versus Ag/AgCl) or a saturated quinhydrone solution, and clean or re-polish the metal surface if readings drift. Platinum surfaces can be cleaned with dilute nitric acid or a mild abrasive. Keep the reference junction filled and free of blockage, and rinse between samples. Readings take longer to stabilize than pH, often one to several minutes, and are sensitive to oxygen, flow rate and temperature. Record pH and temperature with each reading. Replace electrodes when verification fails or response is sluggish. Handle oxidizing and reducing standards with suitable protective equipment and dispose of used solutions according to local rules.
How do I select the right Benchtop ORP/pH Meter?
Choose a benchtop ORP/pH meter for laboratory work that needs 0.1 mV resolution, drift-based stability and documented data. It is not intended for field use. In an RFQ specify mV range and resolution, pH channel needs, electrode metal, data logging and GLP requirements.
How does it compare with other ORP Meters variants?
The decisive choices are the measurement format, the electrode metal and the required stability. Benchtop meters suit laboratory work and method development, portable meters suit field surveys and pool or aquaculture checks, and online analyzers provide continuous measurement with control outputs. Platinum electrodes serve most applications, while gold electrodes are preferred in cyanide-containing samples or where platinum may catalyze unwanted reactions. Select a reference system appropriate for the medium: double-junction references resist poisoning in wastewater. Check that the meter supports mV display with 0.1 mV resolution, relative mV mode and calibration verification with a redox standard such as Zobell or quinhydrone solutions. Because ORP depends on pH, consider a combined pH/ORP instrument. For regulated uses, confirm the requirements of the governing standard or plant procedure.
Full specifications
| mV range | ±1999.9 mV |
|---|---|
| mV resolution | 0.1 mV |
| mV accuracy | ±0.2 mV |
| pH range | −2.000 to 20.000 pH |
| pH accuracy | ±0.002 pH |
| Temperature range | −5 to 105 °C |
| Input impedance | > 10¹² Ω |
| Data storage | ≥ 1000 results |
| Display modes | Absolute mV, relative mV, pH |
| Power supply | 100–240 V AC, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Redox research and method development
- Soil and sediment studies
- Electroplating bath monitoring
- Disinfectant QC
- Food oxidation studies
Key features
- mV resolution of 0.1 mV with ±0.2 mV accuracy over a ±1999.9 mV range
- Absolute and relative mV modes for following changes during reactions
- Standard hydrogen electrode conversion using temperature input
- Drift-based stability criteria before a reading is accepted
- Time-based data logging and graph display for redox processes
- Dual-channel capability with simultaneous pH and ORP measurement
Frequently asked questions about Benchtop ORP/pH Meter
Relative mV mode zeroes the display at a chosen baseline so that changes in potential during a reaction or titration can be followed directly. It helps remove offsets from reference electrodes and is convenient for endpoint detection.
Yes. By entering the reference electrode type and sample temperature, many meters add the appropriate offset to report ORP versus the standard hydrogen electrode. The offset for Ag/AgCl in 3 mol/L KCl is about 200 to 210 mV near 25 degrees Celsius.
ORP depends strongly on pH for many redox couples, so measuring both gives context. A dual-channel instrument allows simultaneous readings and is useful in chemistry, water treatment and biological process studies.
It measures oxidation-reduction potential in millivolts, which indicates how strongly a solution tends to oxidize or reduce other substances. Higher positive values indicate oxidizing conditions, for example chlorinated water, while negative values indicate reducing conditions.
No. ORP responds to the combined effect of all redox species and is affected by pH, temperature and stabilizers, so it is not a direct concentration measurement. It is used as a control signal and cross-check, while chlorine is measured by DPD or amperometric methods.
Immerse it in a redox standard such as Zobell's solution or a quinhydrone solution of known pH and compare the reading with the tabulated value at the temperature. A deviation above about 10 to 20 mV, or slow response, means cleaning or replacement is needed.