Key specifications

Key specifications
Oxygen range0.1 ppm–5%
Nitrogen range0.1 ppm–3%
Hydrogen range0.1 ppm–0.5%
Sample mass0.1–1 g
Autosampler capacity20–50 samples
Cycle time2–3 min per sample
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E1409, ASTM E1447, ASTM E1019

What is the Automated Oxygen-Nitrogen-Hydrogen Analyzer with Autosampler?

An automated oxygen-nitrogen-hydrogen analyzer adds a 20–50 position autosampler with crucible handling to an impulse furnace. It is selected by production and contract laboratories that need unattended gas analysis with documented traceability. It reduces handling errors and improves throughput for routine work.

What is the Automated Oxygen-Nitrogen-Hydrogen Analyzer with Autosampler?

An automated oxygen-nitrogen-hydrogen analyzer adds a 20–50 position autosampler with crucible handling to an impulse furnace. It is selected by production and contract laboratories that need unattended gas analysis with documented traceability. It reduces handling errors and improves throughput for routine work.

Overview

The automated analyzer uses a magazine that stores 20–50 pre-weighed samples, typically pins or capsules, and feeds them sequentially into the furnace. Crucibles are loaded automatically, outgassed, and discarded after analysis, while electrodes and dust filters are cleaned by brush or by automated purge. A sample drop mechanism with sealed load chamber prevents air ingress and keeps blanks low. Balance integration transfers sample weights to the software, which sequences blanks, calibrations, check standards, and unknowns. Cycle times are typically 2–3 minutes per sample. The system is often equipped with oxygen, nitrogen, and hydrogen detection channels and a diagnostic system that logs furnace current, gas pressure, and cell signals. Automation reduces handling errors and improves throughput, but the initial cost and maintenance burden are higher than for a manual instrument.

How does it work?

An oxygen nitrogen hydrogen analyzer places a sample of 0.1–1 g in a high-purity graphite crucible clamped between two electrodes in a sealed furnace flushed with helium or argon. A high current heats the crucible to 2000–3000 °C, melting the sample and releasing its gases. Oxygen reacts with graphite to form CO, nitrogen leaves as N2, and hydrogen as H2. CO and, after oxidation, CO2 are detected by non-dispersive infrared cells, while N2 and H2 are measured by a thermal conductivity cell after the gas stream passes rare earth copper oxide and absorbent traps. Hydrogen may be separated by a molecular sieve column. Results are calibrated against certified reference materials such as steel, titanium, and nickel alloys. Since gases are extracted from the bulk, the analysis gives total content, not surface contamination.

What are the key features?

  • Autosampler magazine holds 20–50 pre-weighed samples with sealed drop chamber.
  • Automatic crucible loading, outgassing, and disposal minimize operator exposure.
  • Balance interface and batch sequencing include blanks and check standards.
  • Diagnostic log records furnace current, gas pressure, and detector signals.
  • Audit trail and user levels support regulated and ISO/IEC 17025 laboratories.

What are the technical specifications?

A typical automated oxygen-nitrogen-hydrogen analyzer with autosampler configuration offers oxygen range of 0.1 ppm–5%, nitrogen range of 0.1 ppm–3%, hydrogen range of 0.1 ppm–0.5%, sample mass of 0.1–1 g, autosampler capacity of 20–50 samples and cycle time of 2–3 min per sample. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Automated Oxygen-Nitrogen-Hydrogen Analyzer with Autosampler is used in high-throughput steel and alloy production labs, third-party metal testing services, additive manufacturing powder lot release and aerospace supply chain inspection. Across the wider Oxygen Nitrogen Hydrogen Analyzers class, laboratories also deploy it for steel cleanliness and gas content control, titanium and zirconium alloy qualification and hydrogen embrittlement investigation.

Which standards and certifications apply?

Relevant standards and methods include ASTM E1409, ASTM E1447, ASTM E1019, ISO 10720, GB/T 11261, GB/T 20124 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Hydrogen and oxygen results depend strongly on sample handling. Steel hydrogen specimens must be quenched in cold water and stored in liquid nitrogen or dry ice to prevent diffusion, and analyzed promptly. Oxygen and nitrogen samples are cleaned, dried, and handled with tongs. Use helium of at least 99.995% purity, regulated pneumatic gas, and cooling water at 15–25 °C. Crucible outgassing is performed before each run and furnace electrodes and dust filters need cleaning after a defined number of analyses, usually 30–100. Calibrate frequently with certified standards and check blanks daily. Installation requires fume extraction and adequate power, since the impulse furnace draws high current. Validate methods against ASTM E1409, ASTM E1447, and ISO 4295-type procedures.

How do I select the right Automated Oxygen-Nitrogen-Hydrogen Analyzer with Autosampler?

Choose the automated version when more than about 30 samples are tested per shift or when traceable unattended operation is needed. Smaller laboratories are usually served by manual systems. Specify magazine size, gas channels, balance interface, data export, and calibration reference materials for your alloy families.

How does it compare with other Oxygen Nitrogen Hydrogen Analyzers variants?

Decide which gases matter and in which matrices. Oxygen and nitrogen in steel and titanium require a standard impulse furnace, while hydrogen in steel at 0.5–10 ppm often calls for a dedicated hydrogen channel or a separate hydrogen analyzer with a thermal conductivity cell. For ceramics and refractory powders that release gas slowly, higher furnace power up to 5–8 kW and longer integration are needed. Specify expected ranges, because ppm-level oxygen needs low-range infrared cells and careful blank control. Consider sample geometry: pins and rods need a cutting station, whereas powders require tin or nickel capsules. Autosamplers with 20–50 positions and automatic crucible handling increase throughput. Check the availability of certified reference materials for your alloys and ask for detection limits, typically 0.05 ppm to 1 ppm, verified on matching materials.

Full specifications

Full specifications
Oxygen range0.1 ppm–5%
Nitrogen range0.1 ppm–3%
Hydrogen range0.1 ppm–0.5%
Sample mass0.1–1 g
Autosampler capacity20–50 samples
Cycle time2–3 min per sample
Furnace powerUp to 6 kW
Precision (RSD)≤1.5% at 50 ppm O or N
Carrier gasHelium ≥99.995%
DetectorsInfrared (O) and thermal conductivity (N, H)

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • High-throughput steel and alloy production labs
  • Third-party metal testing services
  • Additive manufacturing powder lot release
  • Aerospace supply chain inspection

Key features

  • Autosampler magazine holds 20–50 pre-weighed samples with sealed drop chamber.
  • Automatic crucible loading, outgassing, and disposal minimize operator exposure.
  • Balance interface and batch sequencing include blanks and check standards.
  • Diagnostic log records furnace current, gas pressure, and detector signals.
  • Audit trail and user levels support regulated and ISO/IEC 17025 laboratories.

Frequently asked questions about Automated Oxygen-Nitrogen-Hydrogen Analyzer with Autosampler

Samples are loaded into a sealed drop chamber that is purged with carrier gas before release into the furnace. This keeps atmospheric oxygen and nitrogen out of the system, which is critical for ppm-level blanks.

Request a quotation for the Automated Oxygen-Nitrogen-Hydrogen Analyzer with Autosampler