Benchtop Multiparameter Water Analyzer
台式多参数水质分析仪
- SKU MUM-0002
- Multiparameter Meters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Channels | 1–4 simultaneous |
|---|---|
| pH range and resolution | -2 to 20, 0.001 |
| pH accuracy | ±0.002 |
| Conductivity range | 0.01 µS/cm–2000 mS/cm |
| Dissolved oxygen range | 0–60 mg/L |
| Temperature range | -10 to 110 °C, ±0.2 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 10523, ISO 7888, ISO 5814
What is the Benchtop Multiparameter Water Analyzer?
A benchtop multiparameter analyzer measures pH, conductivity, dissolved oxygen and other parameters with stirring and temperature control. It provides the measurement stability, repeatability and documentation required for accredited compliance and research laboratories.
What is the Benchtop Multiparameter Water Analyzer?
A benchtop multiparameter analyzer measures pH, conductivity, dissolved oxygen and other parameters with stirring and temperature control. It provides the measurement stability, repeatability and documentation required for accredited compliance and research laboratories.
Overview
The analyzer combines a pH or ion meter, a conductivity meter and an oxygen meter in one housing with a motorised stirrer and a sample holder that maintains temperature. Better shielding and fixed geometry give lower noise than handheld units, and calibration can be performed with automatic buffer recognition and electrode slope calculation. Dissolved oxygen measurement may use a polarographic or optical sensor, and conductivity can be reported as raw, temperature-compensated or total dissolved solids. Data tables can be exported, and many instruments support multiple channels for simultaneous measurement of several samples. Electrode holders accept pH, ion-selective, conductivity and oxygen probes with a common connector, which makes the analyser suitable for a wide parameter range without changing instruments.
How does it work?
A multiparameter meter combines sensors of different operating principles on one controller. Glass or ISFET electrodes measure pH and other ion activities through a potential that varies with concentration. Conductivity cells apply an alternating current between electrodes and measure the resulting current, which depends on dissolved ions. Dissolved oxygen is measured by a polarographic or galvanic membrane electrode or, in newer instruments, by luminescence quenching of a sensor spot that responds to oxygen. Turbidity is measured optically by scattered light. Temperature is recorded by a thermistor and used to compensate the other readings, because pH, conductivity and oxygen solubility all change with heat. Sensors are calibrated with buffer solutions, standard conductivity solutions and barometric correction before each session.
What are the key features?
- Integrated pH, conductivity and dissolved oxygen measurement
- Motorised stirrer with temperature-controlled sample holder
- Automatic buffer recognition and electrode slope display
- Multiple channels for simultaneous sample measurement
- Data logging with export to spreadsheet and LIMS
- Universal electrode connectors for ion-selective probes
What are the technical specifications?
A typical benchtop multiparameter water analyzer configuration offers channels of 1–4 simultaneous, pH range and resolution of -2 to 20, 0.001, pH accuracy of ±0.002, conductivity range of 0.01 µS/cm–2000 mS/cm, dissolved oxygen range of 0–60 mg/L and temperature range of -10 to 110 °C, ±0.2 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Multiparameter Water Analyzer is used in drinking water compliance testing, wastewater effluent characterisation, laboratory method validation and QC and ultrapure and boiler water monitoring. Across the wider Multiparameter Meters class, laboratories also deploy it for drinking water quality compliance monitoring, wastewater treatment process control and river, lake and groundwater field surveys.
Which standards and certifications apply?
Relevant standards and methods include ISO 10523, ISO 7888, ISO 5814, ISO 7027-1 and ISO/IEC 17025. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Sensor care dominates performance. pH electrodes need storage in buffer or potassium chloride solution and periodic refilling, conductivity cells need cleaning of fouling and bubbles, and optical oxygen sensors need replacement of the sensing cap. Calibration must follow the method: at least two pH buffers bracketing the expected value, standard conductivity solutions near the measuring range and temperature equilibrium of sample and standard. Barometric pressure affects oxygen readings and should be entered or automatically measured. Records of calibration slope, drift and buffer identity are expected for accredited work, and portable meters should be checked against laboratory results periodically to detect sensor ageing.
How do I select the right Benchtop Multiparameter Water Analyzer?
Choose a benchtop analyser when accuracy, repeatability and documentation matter more than portability. Confirm the resolution and accuracy required for each parameter and whether multiple channels are needed. Consider optical dissolved oxygen and ion-selective options if your parameter list will expand.
How does it compare with other Multiparameter Meters variants?
Decide first whether you need field or laboratory measurements and which parameters you must report. Portable meters with interchangeable digital sensors suit river, well and effluent surveys because calibration data travel with the sensor. Benchtop analysers give steadier readings, easier stirring and better documentation for compliance laboratories. Sondes are used where a single probe must be lowered or deployed for long-term profiling of temperature and oxygen stratification. Online analysers provide continuous data for treatment control and alarm functions rather than spot checks. For very low-level work such as ultrapure water, choose a meter with flow-through cells and temperature compensation to 0.1 °C, and confirm the resolution needed for each parameter.
Full specifications
| Channels | 1–4 simultaneous |
|---|---|
| pH range and resolution | -2 to 20, 0.001 |
| pH accuracy | ±0.002 |
| Conductivity range | 0.01 µS/cm–2000 mS/cm |
| Dissolved oxygen range | 0–60 mg/L |
| Temperature range | -10 to 110 °C, ±0.2 °C |
| Stirrer | Motorised, adjustable speed |
| Calibration | Automatic buffer recognition, 1–5 points |
| Data storage | 1000+ records with GLP data |
| Interface | USB, RS-232, LIMS export |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Drinking water compliance testing
- Wastewater effluent characterisation
- Laboratory method validation and QC
- Ultrapure and boiler water monitoring
Key features
- Integrated pH, conductivity and dissolved oxygen measurement
- Motorised stirrer with temperature-controlled sample holder
- Automatic buffer recognition and electrode slope display
- Multiple channels for simultaneous sample measurement
- Data logging with export to spreadsheet and LIMS
- Universal electrode connectors for ion-selective probes
Frequently asked questions about Benchtop Multiparameter Water Analyzer
Fixed electrode geometry, shielding and a stirrer give a steadier signal, and temperature control keeps the sample stable. That reduces noise and drift, allowing resolution and accuracy better than those of handheld instruments.
The meter identifies each buffer from its pH and temperature, then calculates the electrode slope and offset from the measured values. This avoids manual entry errors and shows when an electrode is ageing.
Yes, with a flow-through conductivity cell and temperature compensation to 0.1 °C, because ultrapure water has very low conductivity that would otherwise be influenced by dissolved carbon dioxide and temperature.
Common parameters are pH, temperature, conductivity, total dissolved solids, dissolved oxygen and turbidity. Some meters add oxidation-reduction potential, ammonium, nitrate, chloride or fluoride through ion-selective electrodes or optical sensors.
pH, conductivity and oxygen solubility all change with temperature, so a reading without compensation would vary with the sample temperature rather than its composition. The meter uses the measured temperature to correct the value to a reference temperature.
A portable meter is a handheld controller with a sensor on a cable for spot readings, while a sonde is a self-contained cylindrical probe that can be lowered for depth profiles or deployed for continuous logging in lakes and rivers.
Related models