Benchtop Muffle Furnace
台式马弗炉
- SKU MUF-0001
- Muffle Furnaces
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Chamber volume | 1–8 L |
|---|---|
| Temperature range | RT to 1200 C |
| Temperature uniformity | ±5–10 C |
| Thermocouple type | Type K |
| Heating element | Resistance wire in ceramic fiber |
| Heat-up time to 1000 C | 30–50 min |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, DIN 17052-1
What is the Benchtop Muffle Furnace?
A benchtop muffle furnace is a compact box chamber of one to eight liters for small ashing, ignition and heat-treatment jobs. It is the right choice for teaching, routine analysis and laboratories with limited bench space.
What is the Benchtop Muffle Furnace?
A benchtop muffle furnace is a compact box chamber of one to eight liters for small ashing, ignition and heat-treatment jobs. It is the right choice for teaching, routine analysis and laboratories with limited bench space.
Overview
The benchtop muffle furnace packs a small box chamber, usually 1 to 8 liters, into a unit that sits on a laboratory bench. Elements are embedded in ceramic fiber or light firebrick, and the door hinges upward or to the side. Working temperature reaches 1000 to 1200 C, with specialized models to 1400 C, and a type K thermocouple with PID control is standard. Uniformity of plus or minus 5 to 10 C is typical, adequate for single-crucible work. Heat-up to 1000 C takes 30 to 50 minutes with a 1 to 4 kW element. It holds one to six small crucibles and is chosen for ash determination, ignition tests and teaching when throughput is low and footprint matters.
How does it work?
A muffle furnace places the sample in an insulated box chamber while heating elements, usually resistance wire, silicon carbide rods or molybdenum disilicide, are mounted in the walls or surrounds. Heat reaches the crucible mainly by radiation and conduction, and the muffle isolates the sample from direct element contact and from combustion products. Ceramic fiber or insulating firebrick lines the chamber, and a thermocouple, commonly type K, S or B, measures temperature. A PID or SCR controller follows a setpoint or a programmed ramp and soak profile, and an over-temperature protector guards the elements and chamber. A hinged or vertical-lift door with a heat-resistant gasket limits heat loss. Some models add gas inlets or exhaust ports for combustion products.
What are the key features?
- Compact chamber of 1 to 8 liters
- Embedded elements in ceramic fiber or light firebrick
- Working range 1000 to 1200 C
- Type K thermocouple with PID control
- Upward or side-hinged door
- Over-temperature protection
What are the technical specifications?
A typical benchtop muffle furnace configuration offers chamber volume of 1–8 L, temperature range of RT to 1200 C, temperature uniformity of ±5–10 C, thermocouple type of Type K, heating element of Resistance wire in ceramic fiber and heat-up time to 1000 C of 30–50 min. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Muffle Furnace is used in routine ash determination, ignition and loss on ignition tests, teaching laboratory experiments and small-sample heat treatment. Across the wider Muffle Furnaces class, laboratories also deploy it for ash content determination, residue on ignition and loss on ignition of minerals.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, DIN 17052-1, ASTM D3174, USP <281> and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the furnace on a heat-resistant, non-combustible surface with at least 30 cm clearance, and provide extraction for combustion gases. Never open the door at full temperature, since thermal shock damages the lining and can eject hot material. Use crucibles rated for the temperature and avoid overloading, which reduces uniformity. Allow a slow, programmed warm-up, especially after a new lining is installed, and replace thermocouples and elements on condition or schedule. Calibrate with a reference thermocouple at defined intervals and record results. Keep the chamber free of spills, which attack the lining, and store the furnace dry to protect insulation.
How do I select the right Benchtop Muffle Furnace?
Select the benchtop muffle furnace for low-throughput ashing and teaching where one to six crucibles per run suffice. Box or large-capacity furnaces handle bigger batches. In the RFQ, specify volume, top temperature, controller type, crucible sizes and power supply.
How does it compare with other Muffle Furnaces variants?
Choose a muffle furnace for box-shaped loads, crucibles and routine ashing or heat treatment. Set the maximum temperature with margin above the working setpoint, because element and insulation cost rise steeply with temperature. Match chamber volume to crucible count and sample size, and confirm that the door opening accepts your largest crucible. Decide between a fixed-setpoint and a programmable controller, and choose the thermocouple type for the range. Specify insulation grade, heating-element material, ramp rate and safety protection. For regulated ashing, require uniformity data and calibration ports. Confirm power supply, bench or floor placement and any gas or exhaust connection.
Full specifications
| Chamber volume | 1–8 L |
|---|---|
| Temperature range | RT to 1200 C |
| Temperature uniformity | ±5–10 C |
| Thermocouple type | Type K |
| Heating element | Resistance wire in ceramic fiber |
| Heat-up time to 1000 C | 30–50 min |
| Heating power | 1–4 kW |
| Controller | PID with over-temperature limit |
| Crucible capacity | 1–6 small crucibles |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Routine ash determination
- Ignition and loss on ignition tests
- Teaching laboratory experiments
- Small-sample heat treatment
Key features
- Compact chamber of 1 to 8 liters
- Embedded elements in ceramic fiber or light firebrick
- Working range 1000 to 1200 C
- Type K thermocouple with PID control
- Upward or side-hinged door
- Over-temperature protection
Frequently asked questions about Benchtop Muffle Furnace
Some models reach 1400 C using higher-grade elements and insulation, but most benchtop units stop at 1200 C. Check the continuous, not peak, rating, and confirm the crucible and thermocouple are rated for that temperature.
Typically one to six small crucibles, depending on chamber volume and crucible size. Leave space between crucibles and keep them away from walls so radiation reaches all sides, since crowding reduces uniformity and can slow ashing.
Allow at least 30 cm on all sides and never place it under a shelf or against a wall, since the exterior becomes hot. Keep it on a heat-resistant surface, and locate it where combustion fumes can be extracted safely.
It heats samples in a box chamber to 1000 to 1800 C for ash and residue determination, ignition tests, sintering, calcination and heat treatment. The muffle keeps samples separated from heating elements, protecting both the sample and the elements.
Typically 30 to 60 minutes from room temperature depending on chamber volume and element power. Larger and higher-temperature furnaces take longer. A programmed ramp is recommended to protect elements and lining from thermal stress.
Use porcelain or quartz crucibles for general ashing and ignition, alumina crucibles above about 1200 C, and platinum crucibles for demanding fusion work. The crucible must tolerate the working temperature and not react with the sample or atmosphere.