Multi-Position Heating Magnetic Stirrer Reaction Station
多工位加热磁力搅拌反应工作站
- SKU MPS-0004
- Multi-Position Stirrers
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Number of positions | 6–24 (block dependent) |
|---|---|
| Temperature range | Ambient to 300 °C |
| Temperature accuracy | ±1 °C |
| Block uniformity | ±1.5 °C across wells |
| Stirring speed | 100–1,500 rpm |
| Vial or flask volume | 2–100 mL |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D2035, IEC 61010-1, IEC 61010-2-010
What is the Multi-Position Heating Magnetic Stirrer Reaction Station?
A multi-position heating stirrer reaction station combines a heated aluminum block, magnetic stirring and optional reflux condensers across 6–24 positions. It runs parallel synthesis and reaction screening at controlled temperature with consistent mixing across all vessels. It is best suited to synthetic and process chemistry groups.
What is the Multi-Position Heating Magnetic Stirrer Reaction Station?
A multi-position heating stirrer reaction station combines a heated aluminum block, magnetic stirring and optional reflux condensers across 6–24 positions. It runs parallel synthesis and reaction screening at controlled temperature with consistent mixing across all vessels. It is best suited to synthetic and process chemistry groups.
Overview
A reaction station integrates multi-position magnetic stirring with a temperature-controlled block, so each vial or flask experiences the same temperature and stirring. A PT1000 sensor in the block, with PID regulation and an independent safety cut-out, holds block temperature within about ±1 °C, and temperature ranges typically cover ambient to 200 or 300 °C. Interchangeable blocks fit 6 to 24 vials of 2 to 40 mL or several round-bottom flasks of 25 to 100 mL. Optional condenser plates, cooled by circulating liquid, provide reflux, and gas manifolds allow reactions under nitrogen or argon. Stirring speed is set globally, typically 100 to 1,500 rpm. The station is used in medicinal chemistry, catalysis screening and process research where many conditions are compared side by side.
How does it work?
Multi-position stirrers use one of two drive layouts. In the shared-drive layout, a single motor rotates a belt, gear train or large magnetic array under all positions, so every vessel sees the same speed. In the independent-drive layout, each position has its own motor or electromagnet and can be set separately. Magnetic versions spin coated stir bars in flasks or vials, while paddle versions, such as jar testers, lower shafts with flat blades into beakers and control shear through speed. Heated versions add a hotplate or heating block with a temperature sensor, and some units include reflux condensers or inert gas manifolds. The key performance factor is speed uniformity between positions, which depends on drive accuracy, magnet strength and vessel alignment. Position layout influences bench space and accessibility.
What are the key features?
- Temperature-controlled aluminum block with interchangeable formats
- PT1000 sensor with PID control and independent safety cut-out
- Magnetic stirring at each position with shared speed setting
- Optional reflux condenser plate and inert gas manifold
- Programmable temperature and speed steps
- Suitable for 6–24 vials or multiple round-bottom flasks
What are the technical specifications?
A typical multi-position heating magnetic stirrer reaction station configuration offers number of positions of 6–24 (block dependent), temperature range of Ambient to 300 °C, temperature accuracy of ±1 °C, block uniformity of ±1.5 °C across wells, stirring speed of 100–1,500 rpm and vial or flask volume of 2–100 mL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Multi-Position Heating Magnetic Stirrer Reaction Station is used in parallel organic synthesis, catalyst and reaction condition screening, process research and scale-down studies, heated solubility studies and crystallization screening. Across the wider Multi-Position Stirrers class, laboratories also deploy it for parallel dissolution and solubility screening, liquid-liquid and solid-liquid extraction and coagulation and flocculation jar testing.
Which standards and certifications apply?
Relevant standards and methods include ASTM D2035, IEC 61010-1, IEC 61010-2-010, IEC 61326-1, USP <711>, GB/T 16881 and ISO 9001. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the stirrer on a level, rigid bench and verify that every position is in full contact with its vessel. Check speed uniformity across positions with a tachometer during installation and at intervals, since belt wear or magnet mismatch shifts speed. Use identical vessels and stir bars in all positions to keep mixing comparable. Load positions evenly to avoid vibration. Clean spills promptly, because liquid under the plate can damage drive parts. For heated units, follow the same precautions as hotplate stirrers, including a working safety cut-out. For jar testers, follow the method for paddle geometry and beaker size, such as ASTM D2035. Keep service records and consider preventive maintenance annually.
How do I select the right Multi-Position Heating Magnetic Stirrer Reaction Station?
Select a reaction station when multiple heated reactions must be compared under the same temperature and stirring. For ambient work use a multi-position magnetic stirrer. State block format, temperature range, reflux and inert gas needs, vessel sizes and uniformity specification in your RFQ. Confirm the heater power and block uniformity before ordering.
How does it compare with other Multi-Position Stirrers variants?
First set the number of positions and vessel size, since these determine the footprint and plate geometry. Decide whether all positions can share one speed, which is cheaper and adequate for dissolution or extraction, or whether each needs individual control for optimization studies. Check speed range and uniformity between positions, typically within a few percent, and maximum volume per position. If heating is needed, compare temperature range, uniformity across positions and whether a probe controls the block. For water treatment, choose a jar tester with paddle speed range suited to rapid-mix and slow-mix stages and with a lighted base if turbidity observations are made. Consider chemical resistance, hood fit, interface, and whether programmable speed steps are required. Give position count, flask sizes, speed and temperature range in the inquiry.
Full specifications
| Number of positions | 6–24 (block dependent) |
|---|---|
| Temperature range | Ambient to 300 °C |
| Temperature accuracy | ±1 °C |
| Block uniformity | ±1.5 °C across wells |
| Stirring speed | 100–1,500 rpm |
| Vial or flask volume | 2–100 mL |
| Heating power | 600–1,200 W |
| Temperature sensor | PT1000 |
| Condenser coolant connection | 6–8 mm hose barbs |
| Supply | 220–240 V AC |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Parallel organic synthesis
- Catalyst and reaction condition screening
- Process research and scale-down studies
- Heated solubility studies
- Crystallization screening
Key features
- Temperature-controlled aluminum block with interchangeable formats
- PT1000 sensor with PID control and independent safety cut-out
- Magnetic stirring at each position with shared speed setting
- Optional reflux condenser plate and inert gas manifold
- Programmable temperature and speed steps
- Suitable for 6–24 vials or multiple round-bottom flasks
Frequently asked questions about Multi-Position Heating Magnetic Stirrer Reaction Station
A reaction station applies one temperature profile and stirring speed to all vessels through a single block, so conditions are identical and setup is faster. Separate hotplates allow independent temperatures but are harder to match and take more bench space.
Yes, with a condenser plate and gas manifold fitted to the block. Request the plate material, cooling requirements, septum or cap type and leak-test information to match the solvents and temperatures used.
Use a calibrated reference thermometer or multi-channel data logger in several wells at set points, and compare with the display. Record results and repeat after repair or at defined intervals as part of equipment qualification.
It stirs several vessels simultaneously at the same speed, and sometimes temperature, so multiple samples are processed under identical conditions. Typical uses are parallel dissolution, extraction, solubility screening, reaction optimization and jar testing in water treatment.
Measure rpm at each position with a calibrated non-contact tachometer or stroboscope at several set speeds, and compare with the set value. Differences within a few percent are typical. Repeat at installation, after repairs and at routine intervals.
Independent control suits optimization studies where each vessel needs a different speed. A shared drive is cheaper and gives consistent speed for replicate work such as dissolution or extraction, where the same conditions should apply everywhere.
Related models