Infrared Lamp Moisture Balance
红外灯水分测定仪
- SKU MOB-0002
- Moisture Balances
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Readability | 1–10 mg |
|---|---|
| Sample capacity | 50–120 g |
| Moisture readability | 0.01–0.1% |
| Temperature range | 50–160 C |
| Heating source | Infrared lamp, 250–375 W |
| Time to 105 C | ≈ 2–3 min |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <731>, Ph. Eur. 2.2.32, ISO 712
What is the Infrared Lamp Moisture Balance?
An infrared lamp moisture balance uses a conventional infrared emitter for heating and offers a lower-cost route to loss-on-drying measurement. It suits routine quality control of powders and granules where analysis speed is less critical.
What is the Infrared Lamp Moisture Balance?
An infrared lamp moisture balance uses a conventional infrared emitter for heating and offers a lower-cost route to loss-on-drying measurement. It suits routine quality control of powders and granules where analysis speed is less critical.
Overview
This type uses an infrared lamp, often a quartz or glass emitter of 250 to 375 W, placed above the sample pan. Heating is slower than halogen, reaching 105 C in about 2 to 3 minutes, and the radiation is less intense, so charring of delicate samples is less likely. Readability is typically 1 to 10 mg with capacity 50 to 120 g. Because the control of lamp power is simpler, temperature overshoot is greater and repeatability a little lower than in halogen units, with moisture repeatability of about 0.1 to 0.3 percent for a 5 g sample. Drying programs are basic, with a choice of fixed temperature and time or automatic end-point. Lower cost and simple operation make these instruments common in production-line and teaching laboratories.
How does it work?
A moisture balance applies the thermogravimetric loss-on-drying principle. The sample, typically 0.5 to 20 g, is placed on a pan inside a heating chamber, and its initial mass is recorded. A heater, such as a halogen lamp, infrared emitter, metal tube or microwave source, raises the sample temperature to a set value, commonly 40 to 200 C. A built-in weighing cell records mass continuously as water and other volatiles evaporate. The analysis ends when mass change falls below a defined rate, for example 1 mg per 50 seconds, or after a set time. Moisture content is calculated as mass loss divided by initial mass. Temperature sensors and profiles, such as standard, rapid or stepwise heating, control energy input to avoid decomposition of the sample.
What are the key features?
- Infrared emitter of 250 to 375 W with simple control
- Gentler radiation for delicate samples that char easily
- Fixed-time or automatic end-point drying modes
- Compact unit with LCD and basic memory
- Low purchase and lamp replacement cost
What are the technical specifications?
A typical infrared lamp moisture balance configuration offers readability of 1–10 mg, sample capacity of 50–120 g, moisture readability of 0.01–0.1%, temperature range of 50–160 C, heating source of Infrared lamp, 250–375 W and time to 105 C of ≈ 2–3 min. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Infrared Lamp Moisture Balance is used in production-line moisture checks, teaching laboratories, plastic granule moisture testing and tobacco and feed moisture. Across the wider Moisture Balances class, laboratories also deploy it for food and grain moisture testing, pharmaceutical loss on drying and plastic granule moisture control.
Which standards and certifications apply?
Relevant standards and methods include USP <731>, Ph. Eur. 2.2.32, ISO 712, ISO 6540, AOAC 925.10, ASTM D6980 and GB 5009.3. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the instrument on a level, vibration-free bench, away from drafts and direct heat, since air movement affects the weighing cell. Allow warm-up before use and calibrate the balance with certified weights. Verify temperature with a calibrated temperature kit, because heater drift changes results. Keep the chamber, reflector and pan clean, as residues absorb heat and alter drying. Use consistent sample mass and distribution, for example a thin even layer, to ensure reproducibility. Hazardous or flammable volatile samples can be unsafe in a heated chamber, so assess each method. Document method parameters, and validate against a reference method when compliance is needed.
How do I select the right Infrared Lamp Moisture Balance?
Select the infrared lamp model when budget matters and moisture tolerance is about 0.2 percent or looser. It is slower and less repeatable than halogen. In the RFQ, specify readability, capacity, lamp power, temperature range and number of methods.
How does it compare with other Moisture Balances variants?
Choose the heating technology by sample type. Halogen and infrared units suit most solids and powders, tubular heaters give gentler and more uniform heating for sugars and polymers, and microwave units penetrate large or high-moisture samples quickly. Then check readability, with 1 mg for routine work and 0.1 mg for low-moisture samples or small masses. Consider capacity, usually 50 to 200 g, and temperature range. Validate the method against a reference such as oven drying or Karl Fischer titration, since loss-on-drying also captures other volatiles. Look at programmable drying profiles, data outputs and audit trail for regulated use. Also check sample pans, pan handlers and ease of cleaning, which influence throughput and reproducibility.
Full specifications
| Readability | 1–10 mg |
|---|---|
| Sample capacity | 50–120 g |
| Moisture readability | 0.01–0.1% |
| Temperature range | 50–160 C |
| Heating source | Infrared lamp, 250–375 W |
| Time to 105 C | ≈ 2–3 min |
| Repeatability (5 g sample) | ≈ 0.1–0.3% moisture |
| Drying modes | Timed, automatic end-point |
| Memory | ≥ 10 methods |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Production-line moisture checks
- Teaching laboratories
- Plastic granule moisture testing
- Tobacco and feed moisture
Key features
- Infrared emitter of 250 to 375 W with simple control
- Gentler radiation for delicate samples that char easily
- Fixed-time or automatic end-point drying modes
- Compact unit with LCD and basic memory
- Low purchase and lamp replacement cost
Frequently asked questions about Infrared Lamp Moisture Balance
Both heat by radiation, but halogen lamps reach temperature faster and deliver finer control, giving shorter analysis times and better repeatability. Infrared lamps are cheaper and gentler but slower, so they suit routine checks with looser tolerance.
Typical lifetimes are 1,000 to 3,000 operating hours, depending on temperature and duty cycle. Declining output lengthens drying time, so monitor the time to reach temperature and replace the lamp when it becomes noticeably longer.
It can be used for in-process checks, but official loss-on-drying tests per USP <731> specify defined methods. Validate the analyzer against the compendial oven method and document suitability before using it for release decisions.
It weighs the sample, heats it and records mass continuously while water evaporates. Moisture content equals mass lost divided by initial mass, expressed as a percentage. The test ends when mass stops changing at a defined rate or after a set time.
Loss-on-drying measures all volatiles lost at the set temperature, not only water, so results may differ from Karl Fischer titration, which is specific to water. A validated method can correlate closely, but Karl Fischer remains the reference for low-moisture or heat-sensitive samples.
Typically 1 to 10 g for routine samples, chosen so that the expected moisture loss is well above the balance resolution, often at least 10 mg. Use a thin, even layer to allow uniform drying and avoid overloading the pan.