Vacuum Drying Oven for Food Moisture
食品真空干燥烘箱
- SKU MAN-0006
- Moisture Analyzers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | 40–200 °C |
|---|---|
| Temperature uniformity | ±1 °C at 100 °C |
| Vacuum level | Down to 10 mbar |
| Chamber volume | 50–250 L |
| Shelves | 2–4 adjustable, aluminium or stainless steel |
| Door | Tempered safety glass |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 712, ISO 6496, AOAC 925.10
What is the Vacuum Drying Oven for Food Moisture?
A vacuum drying oven determines moisture gravimetrically at reduced pressure and lower temperature, protecting heat-sensitive and oxidisable food samples. It is the accepted reference method for products that decompose in conventional ovens.
What is the Vacuum Drying Oven for Food Moisture?
A vacuum drying oven determines moisture gravimetrically at reduced pressure and lower temperature, protecting heat-sensitive and oxidisable food samples. It is the accepted reference method for products that decompose in conventional ovens.
Overview
Samples are dried in a chamber held at reduced pressure, commonly 10 to 100 mbar, which lowers the boiling point of water and allows drying at 60 to 80 °C instead of 105 °C. Lower temperature and the absence of air protect sugars, fats and vitamins from decomposition and oxidation, so the mass loss more closely represents water. The oven has a jacketed chamber for even heating, a tempered glass door for observation, and ports for inert gas purging. Sheathed heating elements keep the chamber walls warm to prevent condensation. Samples are dried to constant mass, cooled in a desiccator and weighed, and the result is calculated as a percentage. The technique underpins many official methods for sugar, honey, dairy and high-fat products.
How does it work?
Loss-on-drying instruments weigh a sample, heat it with an infrared or halogen lamp, and track mass until it stabilises; the mass loss is reported as moisture. Halogen lamps reach the drying temperature faster and distribute heat more evenly than infrared. Microwave drying drives water out from within the sample, which suits bulky or dense products. Capacitance meters in grain-moisture devices correlate the dielectric constant of a packed sample with water content using stored calibrations. Karl Fischer titration measures water chemically, by the iodine-sulfur dioxide reaction, and is the reference for low-moisture foods, oils and powders where volatiles would bias loss-on-drying. Vacuum oven drying remains the gravimetric reference method for many commodities.
What are the key features?
- Chamber pressure down to about 10 mbar
- Temperature range 40–200 °C with low-temperature drying
- Jacketed chamber for uniform heat distribution
- Inert gas purge port to reduce oxidation
- Tempered glass door for sample observation
- Independent over-temperature protection
What are the technical specifications?
A typical vacuum drying oven for food moisture configuration offers temperature range of 40–200 °C, temperature uniformity of ±1 °C at 100 °C, vacuum level of Down to 10 mbar, chamber volume of 50–250 L, shelves of 2–4 adjustable, aluminium or stainless steel and door of Tempered safety glass. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Vacuum Drying Oven for Food Moisture is used in reference moisture for sugar and honey, high-fat and heat-sensitive product moisture, dairy powder and infant formula testing and method validation against rapid analysers. Across the wider Moisture Analyzers class, laboratories also deploy it for grain intake moisture and safe storage decisions, nutrition labelling and dry-basis calculations and in-process control of drying and blending.
Which standards and certifications apply?
Relevant standards and methods include ISO 712, ISO 6496, AOAC 925.10, ISO 760, ASTM E203 and ISO/IEC 17025. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Moisture results depend on sample handling, so grinding, portion size, spreading and cooling time must follow the method. Loss-on-drying instruments need periodic verification with reference materials or a drying oven comparison, and the balance inside them should be checked with traceable weights. Karl Fischer reagents are moisture-sensitive and need fresh solvent, correct titration parameters and regular drift checks. Capacitance meters must be set to the right crop calibration and corrected for temperature. Keep records of reference-method comparisons and store instruments away from draughts, direct sunlight and heat sources.
How do I select the right Vacuum Drying Oven for Food Moisture?
Select a vacuum drying oven when you need the reference gravimetric result for heat-sensitive or high-fat products, or when your official method requires reduced pressure. Confirm chamber volume, achievable vacuum and temperature uniformity, and plan desiccator and balance capacity for cooling and weighing.
How does it compare with other Moisture Analyzers variants?
Match the method to the product and to the accuracy you must report. Loss-on-drying analysers are fast and simple and are ideal for routine control of powders, pastes and liquids, but volatile components other than water can cause a positive bias. Halogen models heat faster and suit high sample numbers, while microwave models handle dense or bulky products better. Capacitance meters are convenient for grain at intake but depend on crop-specific calibrations and are affected by temperature. Karl Fischer titration is required for oils, low-moisture powders and any product where the reference method specifies it. Confirm repeatability, sample size and the ability to store and export results.
Full specifications
| Temperature range | 40–200 °C |
|---|---|
| Temperature uniformity | ±1 °C at 100 °C |
| Vacuum level | Down to 10 mbar |
| Chamber volume | 50–250 L |
| Shelves | 2–4 adjustable, aluminium or stainless steel |
| Door | Tempered safety glass |
| Gas purge | Inert gas inlet and vent |
| Control | Digital PID with over-temperature cut-out |
| Drying time | 2–6 h to constant mass |
| Power | 100–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Reference moisture for sugar and honey
- High-fat and heat-sensitive product moisture
- Dairy powder and infant formula testing
- Method validation against rapid analysers
Key features
- Chamber pressure down to about 10 mbar
- Temperature range 40–200 °C with low-temperature drying
- Jacketed chamber for uniform heat distribution
- Inert gas purge port to reduce oxidation
- Tempered glass door for sample observation
- Independent over-temperature protection
Frequently asked questions about Vacuum Drying Oven for Food Moisture
Reduced pressure lowers the boiling point of water, so drying can be done at 60 to 80 °C instead of 105 °C. That protects sugars, fats and vitamins from decomposition, so the measured mass loss is closer to true water content.
The sample is dried, cooled in a desiccator and weighed repeatedly until two consecutive weighings differ by less than a defined amount, commonly 0.5 to 1 mg. Drying to constant mass ensures the endpoint is objective.
It is widely applicable but slow and labour intensive, so it suits reference and validation work rather than routine release testing. Some very high-sugar or high-fat products still require special conditions or a Karl Fischer method.
Loss-on-drying measures any mass lost when the sample is heated, so volatile components such as alcohol or essential oils inflate the result. Karl Fischer titration measures water specifically through a chemical reaction and is preferred for oils and low-moisture products.
Halogen lamps heat rapidly and distribute energy evenly across the sample surface, shortening drying time and improving repeatability. They also allow the temperature to be controlled closely, which matters when a method specifies a drying temperature.
They are accurate for the crop and moisture range covered by their calibration, typically within about 0.5 percent. Accuracy falls for other crops, for very wet or very dry grain and at extreme temperatures, so reference oven drying should be used periodically.