Steel-Wood Laboratory Bench with Epoxy Resin Worktop
钢木结构环氧树脂台面实验台
- ISO 9001 manufacturing (to be confirmed)
- +2
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

移动模块化实验台
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Worktop size | 1200–1800 × 750 mm |
|---|---|
| Working height | 850–900 mm |
| Caster diameter | 100–125 mm total-lock |
| Static load | 200–400 kg |
| Dynamic (moving) load | ≤ 100 kg recommended |
| Frame material | Powder-coated steel tube, 40 × 40 mm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: SEFA 8 (laboratory grade casework), EN 13150 (laboratory workbenches), GB 24820 (laboratory furniture, Chinese national standard)
A mobile modular laboratory bench is a frame-and-worktop unit on locking casters that can be reconfigured or moved between areas. It suits flexible research spaces, pilot plants and teaching rooms where layouts change regularly and services are supplied from overhead or floor panels.
A mobile modular laboratory bench is a frame-and-worktop unit on locking casters that can be reconfigured or moved between areas. It suits flexible research spaces, pilot plants and teaching rooms where layouts change regularly and services are supplied from overhead or floor panels.
Mobile modular benches use a rigid tubular steel frame on heavy-duty locking casters rated for the full load, with plug-in service connections for power, data and gas through ceiling-mounted or floor-mounted service panels. Worktops are sized 1200–1800 mm and can be gang-linked to create larger stations. Underbench units such as mobile pedestals and cabinets are attached or stored separately. Castors have total-lock brakes and are typically 100–125 mm diameter to cross thresholds. Static load ratings of 200–400 kg are common, but dynamic loads while moving should be much lower to protect glassware. This design supports flexible lab concepts and quick changeovers, at the cost of some stiffness compared with anchored benches.
A laboratory bench consists of a structural frame, a worktop and usually base cabinets or drawers. Frames are welded or bolted steel, powder-coated or stainless, sized for distributed loads of typically 200–500 kg per linear metre. Worktops are chosen for chemical and thermal exposure: epoxy resin, phenolic resin, solid-surface, ceramic or stainless steel. Reagent shelves, service spines and pop-up sockets carry electricity, gas, vacuum and water, while drop-in sinks and fume-hood interfaces complete the wet-lab workflow. Leveling feet compensate for floor unevenness, and cantilever or modular frames allow reconfiguration. Finish durability depends on powder-coat film thickness, edge sealing and the resistance of the worktop to acids, solvents and heat per standard surface tests.
A typical mobile modular laboratory bench configuration offers worktop size of 1200–1800 × 750 mm, working height of 850–900 mm, caster diameter of 100–125 mm total-lock, static load of 200–400 kg, dynamic (moving) load of ≤ 100 kg recommended and frame material of Powder-coated steel tube, 40 × 40 mm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Mobile Modular Laboratory Bench is used in flexible research laboratories, pilot plants, teaching and training rooms and temporary project benches. Across the wider Laboratory Benches class, laboratories also deploy it for chemistry teaching and research labs, pharmaceutical QC laboratories and biology and microbiology labs.
Relevant standards and methods include SEFA 8 (laboratory grade casework), EN 13150 (laboratory workbenches), GB 24820 (laboratory furniture, Chinese national standard), ANSI/BIFMA X5.5-style load testing (reference) and ISO 9001 quality management. Certification candidates for this model are ISO 9001 manufacturing, SEFA 8 test report and GREENGUARD-type low emission test; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Plan the room before ordering: floor flatness, door widths, ceiling height, service routes and fume hood positions determine which bench designs are feasible. Anchor tall benches per seismic or safety requirements and level all feet before installing worktops. Seal joints and penetrations with chemical-resistant silicone. Verify electrical safety to IEC 61010-1 room practice and keep services isolated from wet zones. Maintenance is simple: wipe spills promptly, avoid abrasive pads on resin, inspect hinges and drawer runners every six months, and re-seal edges if the coating is breached. Document material resistance charts for safety assessments.
Select a mobile modular bench when layouts change often, such as in start-up labs, shared research spaces or training rooms. Avoid it for vibration-sensitive balances or heavy equipment. Specify caster type and rating, worktop material, service connection method, linking requirements, static load and whether brakes must lock all casters.
Choose by the chemicals and heat the worktop will see first: epoxy resin handles strong acids and solvents, phenolic resin suits general chemistry and teaching, stainless steel suits biology and cleanroom use, and ceramic suits high-temperature work. Then set the load rating, because balances, centrifuges and ovens need rigid frames with vibration control. Decide whether the layout is fixed, height-adjustable or mobile, and whether service spines, sinks or reagent shelves are required. Check total length, depth (typically 750 mm), height (typically 850–900 mm) and accessibility requirements. Finally, verify finish resistance data, edge sealing and manufacturer test reports against SEFA 8 or EN 13150 rather than relying on brochure claims.
| Worktop size | 1200–1800 × 750 mm |
|---|---|
| Working height | 850–900 mm |
| Caster diameter | 100–125 mm total-lock |
| Static load | 200–400 kg |
| Dynamic (moving) load | ≤ 100 kg recommended |
| Frame material | Powder-coated steel tube, 40 × 40 mm |
| Worktop material | Epoxy resin / phenolic / laminate |
| Service connection | Quick-connect electrical, data, gas |
| Linking | Bolt-on gang kit |
| Coating | Epoxy-polyester powder, 60 µm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
When casters are locked on a level floor the bench is stable for general tasks, but it is not recommended for analytical balances or microscopes needing vibration isolation. Use an anchored bench or a dedicated balance table for those instruments.
Utilities are supplied through ceiling-mounted or floor-mounted service panels using flexible hoses, coiled cords or quick-connect couplings. Gas connections should use certified hoses with restraints, and electrical outlets should be protected by RCD devices in line with local wiring rules.
A flat, hard floor with a resilient seamless finish, such as vinyl or epoxy, allows casters to roll smoothly. Avoid soft or uneven surfaces and thresholds higher than about 10 mm, which can tip loaded units or damage glassware.
A laboratory bench has a welded or bolted steel frame, powder-coated or stainless, a chemically resistant worktop such as epoxy resin, phenolic resin or stainless steel, and base cabinets or drawers. Material choice depends on the chemicals, heat and loads expected at the workstation.
Epoxy resin worktops are commonly chosen for strong acids, bases and organic solvents because the solid cast material resists chemical attack through its full thickness. Request chemical resistance data for your specific reagents, and confirm thermal limits, typically around 120–150 °C for short exposure.
Standard benches are typically 750 mm deep and 850–900 mm high for standing work, with lengths in 600 mm modules. Sitting-height benches are about 750 mm, and height-adjustable designs span roughly 650–1000 mm to suit different users and accessibility needs.

钢木结构环氧树脂台面实验台