Live-Cell Imaging System with Incubation Chamber
带培养舱的活细胞成像系统
- SKU ISY-0002
- Imaging Systems
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature control | Ambient +5 to 40 °C, ±0.5 °C |
|---|---|
| CO2 control | 0-10 percent, typically 5 percent |
| Humidity | Up to 90 percent, humidified tray |
| Objective range | 4x to 40x, long working distance |
| Fluorescence channels | 3-6 LED channels |
| Detector | Cooled sCMOS, 16 bit |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61326-1, ISO 9022-1
What is the Live-Cell Imaging System with Incubation Chamber?
A microscope platform enclosed in a temperature, CO2 and humidity-controlled chamber that records the same living cells over hours or several days. It suits proliferation, migration, apoptosis and fluorescent reporter assays that need time-lapse sequences.
What is the Live-Cell Imaging System with Incubation Chamber?
A microscope platform enclosed in a temperature, CO2 and humidity-controlled chamber that records the same living cells over hours or several days. It suits proliferation, migration, apoptosis and fluorescent reporter assays that need time-lapse sequences.
Overview
The live-cell system adds an environmental enclosure to an inverted microscope. Heated stage inserts and chamber walls hold 37 °C within about 0.5 °C, a CO2 controller maintains 5 percent for bicarbonate-buffered medium, and water trays or a humidifier prevent evaporation during long runs. Objectives are usually 4x to 40x with long working distances and high numerical aperture for fluorescence. Illumination is LED-based with fast switching and low intensity to limit phototoxicity, and the camera runs at low noise for short exposures. A motorized stage with an incubator-compatible plate carrier visits multiple positions on a schedule, and software manages focus drift, stage movement, multi-channel acquisition and time-lapse assembly. Some systems accept microfluidic chips, organoids and small animals.
How does it work?
Most life science imaging systems share the same optical path: an excitation source such as an LED, laser or arc lamp sends light through filters or a monochromator to the sample, and an objective collects the emitted light, which a cooled CCD or sCMOS camera converts into digital counts. Fluorescence depends on fluorophores that absorb at one wavelength and emit at a longer one, so filter cubes or tunable filters separate excitation from emission. Brightfield imaging relies on transmitted light and contrast techniques such as phase contrast or differential interference contrast. Motorized stages, autofocus routines and multi-well plate carriers let the system visit many positions in a programmed order, and software assembles the images, applies flat-field and dark corrections, and extracts measurements such as intensity, area, count and morphology.
What are the key features?
- Environmental chamber with 37 °C, CO2 and humidity control.
- Temperature stability within about 0.5 °C.
- Low-intensity LED illumination to limit phototoxicity.
- Motorized multi-position stage with plate carrier.
- Focus drift compensation for multi-day runs.
- Time-lapse and multi-channel acquisition software.
What are the technical specifications?
A typical live-cell imaging system with incubation chamber configuration offers temperature control of Ambient +5 to 40 °C, ±0.5 °C, CO2 control of 0-10 percent, typically 5 percent, humidity of Up to 90 percent, humidified tray, objective range of 4x to 40x, long working distance, fluorescence channels of 3-6 LED channels and detector of Cooled sCMOS, 16 bit. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Live-Cell Imaging System with Incubation Chamber is used in cell proliferation and migration tracking, apoptosis and viability time-lapse, fluorescent reporter gene assays and drug response kinetics in live cells. Across the wider Imaging Systems class, laboratories also deploy it for fluorescence and immunofluorescence microscopy, live-cell dynamics and time-lapse recording and high-content screening and phenotypic assays.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61326-1, ISO 9022-1, ISO 13485 manufacturing and IVDR (EU) 2017/746. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Imaging performance depends on the room as much as on the instrument. Use a vibration-isolated bench away from centrifuges and pumps, keep temperature stable, and limit stray light for long exposures or bioluminescence work. Provide stable power, ideally through a line conditioner, and a network path for image data, which can exceed tens of gigabytes per session. Calibrate the stage, objective magnification and fluorescence channels with reference slides at installation and at defined intervals, and verify camera linearity and dark current. Clean objectives with lens tissue and approved solvent only. Manage data with a documented naming and backup policy, since files are large and often subject to retention requirements.
How do I select the right Live-Cell Imaging System with Incubation Chamber?
Select this variant when the same cells must be followed over time under controlled conditions. Compare chamber stability, minimum time-lapse interval, focus compensation quality and how many positions can be visited per cycle. Confirm that your vessel types fit the plate carrier and that illumination intensity can be reduced for long runs. Specify CO2 control, duration, data handling and analysis modules.
How does it compare with other Imaging Systems variants?
Match the system to the question: fixed-cell morphology and staining favour an inverted fluorescence microscope platform, while dynamic processes need an incubator-enclosed live-cell system. Throughput decides between manual microscopes, plate-capable high-content readers and slide scanners, which differ mainly in automation, plate handling and analysis software. Detection sensitivity is the next filter, since weak luminescence needs deep-cooled cameras and strong fluorophores tolerate less cooling. Check objective range and numerical aperture, excitation channels, camera quantum efficiency and pixel size, stage resolution, autofocus reliability and the image format and analysis tools. Confirm that the software exports raw data and supports the statistics package your team uses.
Full specifications
| Temperature control | Ambient +5 to 40 °C, ±0.5 °C |
|---|---|
| CO2 control | 0-10 percent, typically 5 percent |
| Humidity | Up to 90 percent, humidified tray |
| Objective range | 4x to 40x, long working distance |
| Fluorescence channels | 3-6 LED channels |
| Detector | Cooled sCMOS, 16 bit |
| Stage | Motorized, multi-well plate carrier |
| Time-lapse interval | 1 min to 24 h |
| Recording duration | Up to 7 days unattended |
| Data output | Raw and processed stacks, metadata log |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Cell proliferation and migration tracking
- Apoptosis and viability time-lapse
- Fluorescent reporter gene assays
- Drug response kinetics in live cells
Key features
- Environmental chamber with 37 °C, CO2 and humidity control.
- Temperature stability within about 0.5 °C.
- Low-intensity LED illumination to limit phototoxicity.
- Motorized multi-position stage with plate carrier.
- Focus drift compensation for multi-day runs.
- Time-lapse and multi-channel acquisition software.
Frequently asked questions about Live-Cell Imaging System with Incubation Chamber
Systems with stable temperature, CO2 and humidity routinely run for several days without intervention, and some reach a week. Evaporation and focus drift are the practical limits, so use oil or water immersion choices carefully and enable focus compensation.
It can. Excitation light generates radicals that cause phototoxicity and bleaching. Reduce intensity, shorten exposures, lower the acquisition frequency and consider longer-wavelength channels, then verify that cells behave normally in control wells.
Temperature changes, medium evaporation and mechanical settling all move the sample relative to the objective. Hardware autofocus that reads a reflective surface is more reliable over days than image-based methods on dim samples.
A microscope shows an image to the eye, while an imaging system adds a camera, motorised stage, controlled illumination and software that capture, store and quantify images. That combination enables repeated measurements, multi-well automation and statistical analysis across many samples.
Cooled sCMOS or back-illuminated CCD cameras with quantum efficiency above 80 percent and low read noise are preferred. Deep cooling reduces dark current during long exposures, which matters for weak signals such as bioluminescence or single-molecule fluorescence.
A single 96-well plate recorded in three channels can reach tens of gigabytes, and time-lapse or slide-scanning runs are larger. Plan network transfer speed, working storage and a backup or archival policy before the system is installed.