Automated Immunoblot Processor
全自动免疫印迹处理系统
- SKU IMU-0001
- Immunoblot Systems
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA class II registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Strip capacity | 10–50 strips per run |
|---|---|
| Temperature control | 20–45 °C ±1 °C |
| Reagent positions | 6–12 bottles with level detection |
| Wash cycles | Programmable 1–10 per step |
| Run time | 1–4 h depending on the assay |
| Waste handling | Internal waste container with level alarm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI M53, CLSI EP05
What is the Automated Immunoblot Processor?
An automated immunoblot processor performs the incubation, washing and conjugate steps for membrane strips or blots under program control, then presents them for reading. It suits laboratories with moderate strip volumes that need reproducible timing and reduced hands-on work.
What is the Automated Immunoblot Processor?
An automated immunoblot processor performs the incubation, washing and conjugate steps for membrane strips or blots under program control, then presents them for reading. It suits laboratories with moderate strip volumes that need reproducible timing and reduced hands-on work.
Overview
The instrument holds strips or blots in individual channels or trays and dispenses sample dilution, wash buffer, conjugate and substrate according to a stored protocol. Temperature is maintained within a narrow band because conjugate binding is temperature sensitive, and each step is timed by the instrument rather than by the operator. Between steps the channels are drained and refilled, with program pauses that the operator can use for inspection. Typical capacity is ten to fifty strips per run, and run time is one to four hours depending on the assay. Traceability features include a record of the protocol used, reagent lot numbers and the operator identity, and the software can link each strip position to the sample identifier. Because reagents are handled inside the instrument, exposure to patient material and conjugate is limited.
How does it work?
Immunoblotting starts with proteins that are either separated by polyacrylamide gel electrophoresis and transferred to a membrane, or applied directly as discrete lines on a strip. The membrane is blocked to prevent non-specific binding, then incubated with diluted patient sample so that antibodies in the sample bind to their target antigens. After washing, an enzyme- or fluorophore-labelled anti-human antibody is added, and a substrate produces a visible, luminescent or fluorescent signal proportional to the bound antibody. Strips are read by eye, by a scanning densitometer or by a charge-coupled device camera, and each band is scored as absent, weak, moderate or strong, or quantified as an intensity ratio against a control band. Interpretation criteria for confirmatory assays are set by the manufacturer and by national guidance, and the pattern of reactive bands, not a single band, determines the reported result.
What are the key features?
- Program-controlled incubation, washing and conjugate steps
- Individual channels with drain and refill between steps
- Temperature control within a narrow band for binding consistency
- Capacity of ten to fifty strips per run
- Protocol, reagent lot and operator traceability records
- Program pauses for operator inspection if required
What are the technical specifications?
A typical automated immunoblot processor configuration offers strip capacity of 10–50 strips per run, temperature control of 20–45 °C ±1 °C, reagent positions of 6–12 bottles with level detection, wash cycles of Programmable 1–10 per step, run time of 1–4 h depending on the assay and waste handling of Internal waste container with level alarm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Immunoblot Processor is used in infectious disease confirmatory testing, autoimmune antibody line immunoassays, lyme and syphilis confirmation and high-volume reference laboratory blotting. Across the wider Immunoblot Systems class, laboratories also deploy it for HIV and hepatitis confirmatory testing, autoimmune antibody profile testing and lyme disease and syphilis confirmation.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI M53, CLSI EP05, CLSI EP17, WHO HIV testing strategy, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Work on a clean bench with gloves, since membranes are easily contaminated, and use only the buffers and dilutions specified in the kit, because salt concentration and pH change binding and washing efficiency. Keep incubation temperatures and times consistent, as band intensity varies with both, and avoid letting strips dry out between steps. Verify performance at installation with the kit's positive and negative controls and with a proficiency panel if available, and repeat the check with each new reagent lot. Clean the scanner or imaging optics regularly, keep the light source stable for fluorescence and luminescence work, and store images together with the patient identifier for the retention period required by local rules.
How do I select the right Automated Immunoblot Processor?
Specify this variant when strip volume exceeds what can be handled reliably by hand, typically more than thirty strips per week, or when reproducible timing is critical for interpretation. In the RFQ state the strip format and kit protocols to be supported, the required temperature range, and whether the software can map strip positions to sample identifiers for traceability.
How does it compare with other Immunoblot Systems variants?
Decide first whether the laboratory processes strips manually or needs automated incubation and washing, because the processing step dominates hands-on time and reproducibility. Then choose the reading method: visual reading suits low volumes and is accepted for many line immunoassays, densitometry provides objective band intensity, and camera-based imaging supports chemiluminescence and multiplex fluorescence. Check that the instrument accepts the strip and membrane formats of your kits, that the software applies the manufacturer interpretation criteria, and that images and results are archived in a retrievable format. Confirm assay registration in your market, and the availability of controls, conjugates and substrates, since these consumables are kit specific and may have short shelf lives.
Full specifications
| Strip capacity | 10–50 strips per run |
|---|---|
| Temperature control | 20–45 °C ±1 °C |
| Reagent positions | 6–12 bottles with level detection |
| Wash cycles | Programmable 1–10 per step |
| Run time | 1–4 h depending on the assay |
| Waste handling | Internal waste container with level alarm |
| Protocols | Up to 50 stored protocols |
| Data storage | 10,000 run records with strip mapping |
| Interfaces | USB, LAN with LIS option |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Infectious disease confirmatory testing
- Autoimmune antibody line immunoassays
- Lyme and syphilis confirmation
- High-volume reference laboratory blotting
Key features
- Program-controlled incubation, washing and conjugate steps
- Individual channels with drain and refill between steps
- Temperature control within a narrow band for binding consistency
- Capacity of ten to fifty strips per run
- Protocol, reagent lot and operator traceability records
- Program pauses for operator inspection if required
Frequently asked questions about Automated Immunoblot Processor
Most processors handle ten to fifty strips per run, depending on the channel design. Because the run time is one to four hours, batching strips by protocol and by the same reagent lot improves efficiency and reduces the number of separate runs needed each week.
Usually not, because strip protocols, reagent volumes and incubation times come from the kit manufacturer. Some instruments allow open protocol programming, but the laboratory then becomes responsible for validating sensitivity, specificity and interpretation criteria for that combination.
It improves the consistency of the reaction by standardizing timing, temperature and washing, which removes much of the variation seen in manual processing. Interpretation itself still depends on the reading method and on trained readers, unless densitometry or imaging with defined criteria is used.
Most instruments record the interrupted step and either resume or require the run to be repeated with new strips according to the kit instructions. Laboratories should include this scenario in their downtime procedure and keep spare strips and reagents to allow a repeat run.
Western blot separates proteins by electrophoresis and transfers them to a membrane, so bands are positioned by molecular weight. Line immunoassay applies purified or recombinant antigens as discrete lines on a strip. Both are read by band pattern, and kits indicate which interpretation criteria apply.
It is accepted for many confirmatory assays when the kit instructions define scoring categories and the laboratory documents reader training and periodic competency assessment. Densitometry or imaging adds objectivity and an archived record, which many laboratories prefer for traceability and for resolving discrepant readings.
ISO 15189 covers laboratory quality, CLSI M53 addresses criteria for laboratory testing and diagnosis of HIV, and national programmes publish their own testing strategies. Precision and detection limit studies follow CLSI EP05 and EP17, and instrument electrical safety follows IEC 61010-1 and IEC 61010-2-101.