Laser Ablation ICP-MS System

激光烧蚀 ICP-MS 系统

  • SKU ICM-0006
  • ICP-MS
  • CE (to be confirmed)
  • Laser safety class 4 enclosure (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Laser type193 nm excimer or 213 nm Nd:YAG
Spot size5–200 µm
Repetition rate1–100 Hz
Carrier gashelium with argon makeup
Spatial resolutiondown to about 5 µm
Ablation cellfast washout, low dispersion
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ICH Q3D Elemental Impurities, USP <233> Elemental Impurities — Procedures, USP <730> Plasma Spectrochemistry

What is the Laser Ablation ICP-MS System?

A laser ablation ICP-MS system couples a focused laser to the plasma to sample solid materials directly. It is chosen for spatially resolved elemental mapping and for solids that are difficult or undesirable to dissolve.

What is the Laser Ablation ICP-MS System?

A laser ablation ICP-MS system couples a focused laser to the plasma to sample solid materials directly. It is chosen for spatially resolved elemental mapping and for solids that are difficult or undesirable to dissolve.

Overview

A laser ablates a small amount of solid sample in a helium-filled cell, and the resulting aerosol is transported by gas into the ICP, where it is ionized and analyzed by the mass spectrometer. Because no digestion is required, contamination and analyte loss are reduced and sample throughput rises, while spatial resolution lets analysts map element distributions across a surface, such as inclusions in minerals, layers in coatings or elemental patterns in biological tissue. Spot sizes range from about 5 to 200 micrometres, and repetition rates determine the sampling density. Quantification uses matrix-matched solid reference materials, since ablation yield varies with material. The technique is widely used in geochemistry, materials science and biology, and can be combined with most ICP-MS analyzers.

How does it work?

A plasma torch at atmospheric pressure ionizes the sample aerosol. Ions are extracted through a two-stage interface of sampling and skimmer cones into a vacuum region, then focused by ion optics and separated by a mass analyzer according to mass-to-charge ratio. The most common analyzer is a quadrupole, which scans rapidly across selected masses; sector field instruments provide high resolution or high sensitivity, multicollector instruments measure isotope ratios precisely, and time-of-flight analyzers record all masses simultaneously. Collision and reaction cells filled with helium, hydrogen or reactive gases suppress polyatomic interferences such as argon chloride on arsenic or argon argon on selenium. Detection uses electron multipliers with pulse counting and analog modes to cover a wide dynamic range. Calibration uses external standards, internal standards and, when needed, isotope dilution, with careful control of blanks and matrix effects.

What are the key features?

  • Laser cell with helium carrier gas
  • Spot sizes from about 5 to 200 µm
  • Spatially resolved elemental mapping
  • Minimal sample preparation for solids
  • Matrix-matched solid reference calibration
  • Compatible with most ICP-MS analyzers

What are the technical specifications?

A typical laser ablation icp-ms system configuration offers laser type of 193 nm excimer or 213 nm Nd:YAG, spot size of 5–200 µm, repetition rate of 1–100 Hz, carrier gas of helium with argon makeup, spatial resolution of down to about 5 µm and ablation cell of fast washout, low dispersion. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Laser Ablation ICP-MS System is used in mineral and fluid inclusion geochemistry, coating, multilayer and alloy mapping, biological tissue element imaging and forensic and archaeological materials. Across the wider ICP-MS class, laboratories also deploy it for elemental impurity testing per ICH Q3D and USP <233>, ultratrace metals in water and environmental samples and clinical and forensic trace element analysis.

Which standards and certifications apply?

Relevant standards and methods include ICH Q3D Elemental Impurities, USP <233> Elemental Impurities — Procedures, USP <730> Plasma Spectrochemistry, ISO 17294-2 Water quality — ICP-MS determination of elements, US EPA Method 200.8, US EPA Method 6020B and ISO/IEC 17025. Certification candidates for this model are CE, Laser safety class 4 enclosure and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

ICP-MS requires high-purity argon, a vacuum system with roughing and turbomolecular pumps, stable power and a temperature-controlled room. Interface cones, torch and sample introduction parts wear and must be inspected and replaced, and cone condition affects sensitivity and stability. Contamination is critical at nanogram per litre levels, so clean sample preparation areas, ultrapure acids and dedicated labware are essential. Matrix effects require internal standards, dilution or matrix matching, and high dissolved solids need dilution or a robust interface. Daily tuning, mass calibration and performance checks with a multi-element standard maintain data quality. Add automation and audit trails for regulated environments and monitor collision gas and pump oil.

How do I select the right Laser Ablation ICP-MS System?

Select a laser ablation system when spatial information or undissolved solids are central to the analysis, and confirm laser wavelength and spot size suit your material. Specify the required spatial resolution and the availability of matrix-matched reference materials. Ensure the laser cell, transport tubing and ICP-MS have fast response for imaging.

How does it compare with other ICP-MS variants?

Select an ICP-MS configuration by the required detection limits, the number of elements, the isotope information needed and the matrix. A single quadrupole with a collision cell handles most routine ultratrace work economically. A triple quadrupole adds reaction-cell mass selection for difficult interferences and low-level sulfur, phosphorus and halogens. High-resolution sector field instruments resolve spectral overlaps and offer higher sensitivity for semiconductor and geochemical work. Multicollector instruments provide the precision needed for isotope ratio studies. Time-of-flight instruments capture the full mass spectrum for rapid multi-element or single-particle analysis. Laser ablation adds direct solid sampling. Match the sample introduction, collision gas and software to your matrices and regulatory requirements.

Full specifications

Full specifications
Laser type193 nm excimer or 213 nm Nd:YAG
Spot size5–200 µm
Repetition rate1–100 Hz
Carrier gashelium with argon makeup
Spatial resolutiondown to about 5 µm
Ablation cellfast washout, low dispersion
Detection limit0.01–1 mg/kg typical
CouplingICP-MS or ICP-OES
Sample sizeup to 100 mm across
Imaging softwareelemental mapping and profiles

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Mineral and fluid inclusion geochemistry
  • Coating, multilayer and alloy mapping
  • Biological tissue element imaging
  • Forensic and archaeological materials

Key features

  • Laser cell with helium carrier gas
  • Spot sizes from about 5 to 200 µm
  • Spatially resolved elemental mapping
  • Minimal sample preparation for solids
  • Matrix-matched solid reference calibration
  • Compatible with most ICP-MS analyzers

Frequently asked questions about Laser Ablation ICP-MS System

Helium gives smaller, more uniform particles and more efficient transport to the plasma than argon, which improves signal stability and reduces elemental fractionation. Argon is usually added after the cell to match the plasma gas flow. The gas flow rate and tubing length are optimized for fast washout.