Skip to main content
Lab Manufacturers China
ICP Atomic Emission Spectrometer for Process and Online Analysis — product photo

ICP Atomic Emission Spectrometer for Process and Online Analysis

过程与在线分析用电感耦合等离子体原子发射光谱仪

  • SKU ICA-0006
  • ICP-AES
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • ATEX or hazardous area option (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Wavelength range165–800 nm
Enclosureindustrial cabinet, IP54 or better
Measurement interval1–15 min programmable
Detection limit10–100 µg/L typical
Sample conditioningcooling, filtration, dilution
Outputs4–20 mA, Modbus, Ethernet
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <730> Plasma Spectrochemistry, ISO 11885 Water quality — ICP-OES determination of elements, US EPA Method 200.7

What is the ICP Atomic Emission Spectrometer for Process and Online Analysis?

This ICP atomic emission spectrometer is packaged for online process measurement with rugged enclosures and control interfaces. It is chosen for direct continuous metals monitoring in plating baths, brines and hydrometallurgical streams.

What is the ICP Atomic Emission Spectrometer for Process and Online Analysis?

This ICP atomic emission spectrometer is packaged for online process measurement with rugged enclosures and control interfaces. It is chosen for direct continuous metals monitoring in plating baths, brines and hydrometallurgical streams.

Overview

Process ICP systems place the spectrometer in an industrial enclosure and connect it to the process through an automatic sampling or flow system. Rugged optics, sealed electronics and vibration-tolerant mounting protect performance in plant conditions, and the instrument reports results through analog outputs, digital protocols such as Modbus, or a distributed control system. Automatic calibration and check standards maintain accuracy during unattended operation, and alarms act when values drift or exceed limits. Applications include plating bath composition, brine and acid concentration, hydrometallurgical leach solutions and process water. Sample conditioning such as cooling, filtration or dilution is often required before the plasma. Because the method runs continuously, robustness, consumable life and remote diagnostics matter as much as detection limits.

How does it work?

An argon plasma at 6000 to 10000 K, sustained by a radio-frequency coil around a quartz torch, excites atoms and ions in the sample to higher energy states. As they return to lower states they emit light at element characteristic wavelengths. The emission is directed to a spectrometer that separates the wavelengths and measures their intensity, which is proportional to concentration over a wide range. Sample introduction converts the liquid into an aerosol through a nebulizer and spray chamber; organic solvents may need additional oxygen or a cooled interface. Because many lines are available, analysts select lines free from overlap and within the working range. Internal standards correct for drift and matrix effects, and background correction removes continuum and stray light. Plasma conditions are set by power, gas flows and observation position, and are optimized per method.

What are the key features?

  • Industrial enclosure with sealed electronics
  • Automatic sampling or flow cell interface
  • Analog and digital outputs to control systems
  • Automatic calibration and check standards
  • Alarms for drift and limit exceedance
  • Remote diagnostics and service support

What are the technical specifications?

A typical icp atomic emission spectrometer for process and online analysis configuration offers wavelength range of 165–800 nm, enclosure of industrial cabinet, IP54 or better, measurement interval of 1–15 min programmable, detection limit of 10–100 µg/L typical, sample conditioning of cooling, filtration, dilution and outputs of 4–20 mA, Modbus, Ethernet. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The ICP Atomic Emission Spectrometer for Process and Online Analysis is used in plating bath and surface treatment control, hydrometallurgical leach and raffinate streams, brine, acid and process water monitoring and metal finishing and battery material production. Across the wider ICP-AES class, laboratories also deploy it for routine metals in water and wastewater, alloy, steel and metallurgical quality control and food and beverage multi-element analysis.

Which standards and certifications apply?

Relevant standards and methods include USP <730> Plasma Spectrochemistry, ISO 11885 Water quality — ICP-OES determination of elements, US EPA Method 200.7, ASTM D5185, EN 15763 Foodstuffs — Determination of trace elements and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and ATEX or hazardous area option; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install ICP-AES systems with high-purity argon, adequate exhaust and stable power, and keep the room temperature controlled to protect optics and detectors. Organic solvent methods require additional safety measures because solvent vapor can extinguish the plasma or ignite, so oxygen addition and solvent-resistant tubing are used. Torches and injectors degrade through salt deposition and thermal stress and need scheduled inspection. Sample digestion in ultrapure acid avoids contamination and keeps dissolved solids low. Run daily wavelength calibration, a check standard and QC samples, and record torch, nebulizer and pump tubing usage. Argon consumption and chiller performance should be monitored because they affect cost and stability.

How do I select the right ICP Atomic Emission Spectrometer for Process and Online Analysis?

Select a process ICP system when metals must be monitored continuously or frequently at the process, when laboratory turnaround is too slow, or when control actions depend on real-time composition. Specify the stream composition, ranges, required interval and control interface. Confirm sample conditioning, service access, consumable life and remote support before installation.

How does it compare with other ICP-AES variants?

Select an ICP-AES system by the sample type, the elements to be measured and the required throughput. Simultaneous instruments record many lines at once for large panels and high sample numbers, while sequential instruments offer flexibility and lower cost. Viewing configuration determines the balance between detection limits and matrix tolerance. Organic solvent analysis needs a torch, nebulizer and interface designed for volatile carbon loads and often an oxygen addition line. Inert sample paths are required for hydrofluoric acid digests and for high-purity semiconductor materials. Process and online systems add rugged enclosures and control interfaces. Confirm wavelength coverage, resolution, argon consumption and the software features your laboratory needs, including interference correction and audit trails.

Full specifications

Full specifications
Wavelength range165–800 nm
Enclosureindustrial cabinet, IP54 or better
Measurement interval1–15 min programmable
Detection limit10–100 µg/L typical
Sample conditioningcooling, filtration, dilution
Outputs4–20 mA, Modbus, Ethernet
RF power1200–1600 W
Argon consumption14–20 L/min
Operating temperature5–40 °C controlled
Automatic calibrationscheduled with standards

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Plating bath and surface treatment control
  • Hydrometallurgical leach and raffinate streams
  • Brine, acid and process water monitoring
  • Metal finishing and battery material production

Key features

  • Industrial enclosure with sealed electronics
  • Automatic sampling or flow cell interface
  • Analog and digital outputs to control systems
  • Automatic calibration and check standards
  • Alarms for drift and limit exceedance
  • Remote diagnostics and service support

Frequently asked questions about ICP Atomic Emission Spectrometer for Process and Online Analysis

Process streams often need cooling, pressure reduction, filtration and sometimes dilution to bring temperature, particulates and dissolved solids within the instrument limits. A dedicated sampling system with automatic flushing prevents blockages. Conditioning must not change analyte concentration or introduce contamination.

Related models

All ICP-AES

Request a quotation for the ICP Atomic Emission Spectrometer for Process and Online Analysis

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote