Dual-View ICP Atomic Emission Spectrometer
双向观测电感耦合等离子体原子发射光谱仪
- SKU ICA-0003
- ICP-AES
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- 21 CFR Part 11 software compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Wavelength range | 165–900 nm |
|---|---|
| Viewing modes | axial and radial |
| Detection limit (axial) | 0.1–2 µg/L typical |
| Detection limit (radial) | 1–20 µg/L typical |
| Dissolved solids tolerance | up to 20% (radial) |
| Detector | CCD or CMOS array |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <730> Plasma Spectrochemistry, ISO 11885 Water quality — ICP-OES determination of elements, US EPA Method 200.7
What is the Dual-View ICP Atomic Emission Spectrometer?
A dual-view ICP atomic emission spectrometer can observe the plasma axially or radially. It is chosen when a laboratory must measure both ultratrace and major or high-matrix elements on one platform in routine work.
What is the Dual-View ICP Atomic Emission Spectrometer?
A dual-view ICP atomic emission spectrometer can observe the plasma axially or radially. It is chosen when a laboratory must measure both ultratrace and major or high-matrix elements on one platform in routine work.
Overview
A movable mirror or optical switch directs emission from either the end or the side of the plasma to the spectrometer, and the software chooses the view for each element and line. Ultratrace elements use the axial view for maximum sensitivity, while major elements and high-solids samples use the radial view to avoid self-absorption and detector saturation. This gives a single method broad coverage from micrograms per litre to percent levels without operator intervention. The instrument has more optics and alignment requirements than fixed-view systems, and it costs more, but it reduces the need for separate instruments or manual dilution. It is common in environmental, food and pharmaceutical laboratories where sample matrices and concentration ranges vary widely.
How does it work?
An argon plasma at 6000 to 10000 K, sustained by a radio-frequency coil around a quartz torch, excites atoms and ions in the sample to higher energy states. As they return to lower states they emit light at element characteristic wavelengths. The emission is directed to a spectrometer that separates the wavelengths and measures their intensity, which is proportional to concentration over a wide range. Sample introduction converts the liquid into an aerosol through a nebulizer and spray chamber; organic solvents may need additional oxygen or a cooled interface. Because many lines are available, analysts select lines free from overlap and within the working range. Internal standards correct for drift and matrix effects, and background correction removes continuum and stray light. Plasma conditions are set by power, gas flows and observation position, and are optimized per method.
What are the key features?
- Switchable axial and radial plasma observation
- Automatic per-element view selection in software
- Coverage from µg/L to percent in one method
- Avoids self-absorption for major elements
- Reduces need for dilution or separate instruments
- Additional alignment checks in maintenance
What are the technical specifications?
A typical dual-view icp atomic emission spectrometer configuration offers wavelength range of 165–900 nm, viewing modes of axial and radial, detection limit (axial) of 0.1–2 µg/L typical, detection limit (radial) of 1–20 µg/L typical, dissolved solids tolerance of up to 20% (radial) and detector of CCD or CMOS array. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Dual-View ICP Atomic Emission Spectrometer is used in environmental samples across wide ranges, food and agricultural multi-element analysis, pharmaceutical elemental impurity testing and industrial quality control with variable matrices. Across the wider ICP-AES class, laboratories also deploy it for routine metals in water and wastewater, alloy, steel and metallurgical quality control and food and beverage multi-element analysis.
Which standards and certifications apply?
Relevant standards and methods include USP <730> Plasma Spectrochemistry, ISO 11885 Water quality — ICP-OES determination of elements, US EPA Method 200.7, ASTM D5185, EN 15763 Foodstuffs — Determination of trace elements and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and 21 CFR Part 11 software compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install ICP-AES systems with high-purity argon, adequate exhaust and stable power, and keep the room temperature controlled to protect optics and detectors. Organic solvent methods require additional safety measures because solvent vapor can extinguish the plasma or ignite, so oxygen addition and solvent-resistant tubing are used. Torches and injectors degrade through salt deposition and thermal stress and need scheduled inspection. Sample digestion in ultrapure acid avoids contamination and keeps dissolved solids low. Run daily wavelength calibration, a check standard and QC samples, and record torch, nebulizer and pump tubing usage. Argon consumption and chiller performance should be monitored because they affect cost and stability.
How do I select the right Dual-View ICP Atomic Emission Spectrometer?
Select a dual-view instrument when sample matrices and concentration ranges vary, or when one platform must cover both ultratrace and percent-level elements. Specify the element list, ranges and matrices, and confirm that view switching is validated for the lines you use. Budget for periodic alignment maintenance.
How does it compare with other ICP-AES variants?
Select an ICP-AES system by the sample type, the elements to be measured and the required throughput. Simultaneous instruments record many lines at once for large panels and high sample numbers, while sequential instruments offer flexibility and lower cost. Viewing configuration determines the balance between detection limits and matrix tolerance. Organic solvent analysis needs a torch, nebulizer and interface designed for volatile carbon loads and often an oxygen addition line. Inert sample paths are required for hydrofluoric acid digests and for high-purity semiconductor materials. Process and online systems add rugged enclosures and control interfaces. Confirm wavelength coverage, resolution, argon consumption and the software features your laboratory needs, including interference correction and audit trails.
Full specifications
| Wavelength range | 165–900 nm |
|---|---|
| Viewing modes | axial and radial |
| Detection limit (axial) | 0.1–2 µg/L typical |
| Detection limit (radial) | 1–20 µg/L typical |
| Dissolved solids tolerance | up to 20% (radial) |
| Detector | CCD or CMOS array |
| View selection | automatic per element |
| RF power | 1000–1600 W |
| Argon consumption | 14–20 L/min |
| Autosampler | up to 240 positions |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Environmental samples across wide ranges
- Food and agricultural multi-element analysis
- Pharmaceutical elemental impurity testing
- Industrial quality control with variable matrices
Key features
- Switchable axial and radial plasma observation
- Automatic per-element view selection in software
- Coverage from µg/L to percent in one method
- Avoids self-absorption for major elements
- Reduces need for dilution or separate instruments
- Additional alignment checks in maintenance
Frequently asked questions about Dual-View ICP Atomic Emission Spectrometer
No, dual-view ICP-AES extends optical emission detection limits downward but does not reach the nanogram per litre range of ICP-MS. It reduces the need for dilution and separate radial and axial instruments. For ultratrace work or isotope ratios, ICP-MS is still required.
The method stores a view setting for each element and line, and the instrument software moves the optical element before measurement. High-concentration lines are assigned radial view and low-level lines axial view. Analysts can override the setting during method development.
In axial mode the detection limits are comparable, since the optical path and detector are equivalent. The small additional optical elements in a dual-view system can slightly reduce throughput, so exact limits may differ marginally, but the difference is usually minor compared with instrument-to-instrument variation.
They describe the same measurement principle: atomic emission from an inductively coupled plasma. The older term ICP-AES emphasises atomic emission, and ICP-OES emphasises optical emission spectrometry. Instrument designs and wavelengths are equivalent, and method performance depends on the specific configuration rather than the acronym.
Organic solvents increase the carbon load and can extinguish the plasma or cause carbon deposition on the torch. Oxygen is often added to the aerosol gas to burn the carbon, a cooled interface protects the injector, and a solvent-resistant pump tubing and nebulizer are used. Method development establishes suitable power and oxygen flow.
An inert path with a platinum or ceramic injector and a polypropylene or PFA spray chamber is needed for hydrofluoric acid digests, which attack quartz, and for high-purity materials where silicon or boron contamination must be avoided. It is also useful for samples that corrode glass components.
Related models



ICP Atomic Emission Spectrometer for Organic Solvent Analysis
有机溶剂分析用电感耦合等离子体原子发射光谱仪
- CE (to be confirmed)
- +2