Graphite Element High-Temperature Furnace
石墨加热高温炉
- SKU HTF-0003
- High Temperature Furnaces
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Hot zone size | 150×150×250 to 500×500×800 mm |
|---|---|
| Maximum temperature | 2000–3000 C |
| Working vacuum | 1–100 Pa |
| Heating element | Graphite |
| Insulation | Graphite felt or rigid graphite |
| Temperature measurement | Type C thermocouple or pyrometer |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, IEC 60519-1
What is the Graphite Element High-Temperature Furnace?
A graphite element high-temperature furnace reaches 2000 to 3000 C under vacuum or inert gas. It is chosen for sintering, graphitization and melting of materials that require ultra-high temperature without any oxygen present.
What is the Graphite Element High-Temperature Furnace?
A graphite element high-temperature furnace reaches 2000 to 3000 C under vacuum or inert gas. It is chosen for sintering, graphitization and melting of materials that require ultra-high temperature without any oxygen present.
Overview
This furnace uses graphite elements and graphite felt or rigid graphite insulation inside a water-cooled shell, with vacuum or inert gas to prevent oxidation. Working temperature reaches 2000 to 3000 C, though practical limits depend on the load and insulation grade, and hot zones are usually 200 to 600 mm. Because graphite is the element and the insulation, the chamber is chemically reducing and contains no oxygen, which suits carbide and nitride processing and graphitization. Temperature is measured with type C thermocouples up to about 2300 C and optical pyrometers above. Pumping stages produce vacuum of 1 to 100 Pa or better, and partial pressure with argon controls evaporation. It serves advanced materials research, hard-metal sintering and crystal growth.
How does it work?
High-temperature furnaces concentrate heat in a densely insulated hot zone using elements that remain stable at extreme temperature. Silicon carbide and molybdenum disilicide resist oxidation in air to about 1600 to 1800 C, while graphite and tungsten elements work beyond 2000 C under vacuum or inert gas because they oxidize in air. Induction furnaces instead use an alternating magnetic field to induce currents in a conductive crucible or susceptor, heating the charge directly. Dense alumina, zirconia or graphite insulation limits heat loss, and water-cooled shells protect the structure. Type B or C thermocouples, optical pyrometers and radiation sensors cover the range, and programmable controllers follow slow ramp profiles that avoid thermal shock. Atmosphere control is often essential to prevent oxidation, evaporation or contamination of the sample.
What are the key features?
- Graphite elements and graphite felt insulation
- Working range 2000 to 3000 C
- Vacuum or inert-gas operation
- Water-cooled shell and electrodes
- Type C thermocouple or optical pyrometer
- Partial-pressure control with argon
What are the technical specifications?
A typical graphite element high-temperature furnace configuration offers hot zone size of 150×150×250 to 500×500×800 mm, maximum temperature of 2000–3000 C, working vacuum of 1–100 Pa, heating element of Graphite, insulation of Graphite felt or rigid graphite and temperature measurement of Type C thermocouple or pyrometer. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Graphite Element High-Temperature Furnace is used in graphitization of carbon materials, ultra-high-temperature sintering, silicon carbide and nitride processing, crystal growth from melt and advanced materials research. Across the wider High Temperature Furnaces class, laboratories also deploy it for advanced ceramic sintering, refractory material testing and glass and frit melting.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, IEC 60519-1, DIN 17052-1, ISO 9001 and ISO 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
High-temperature furnaces need rigid foundations, generous clearances and, for water-cooled types, reliable cooling with flow and temperature interlocks. Install gas and vacuum lines with proper purging and leak checking, and never heat a graphite or refractory-metal element in air. Warm up and cool slowly according to the schedule to protect dense refractories and elements from thermal shock. Replace elements and thermocouples as matched sets and on condition. Verify temperature with a reference instrument and profile the hot zone periodically, keep records, and train operators on atmosphere, water and emergency shutdown procedures.
How do I select the right Graphite Element High-Temperature Furnace?
Select the graphite furnace when the process needs 2000 C or more and an oxygen-free, chemically reducing environment. Resistance furnaces with oxide elements cannot reach this range. In the RFQ, specify top temperature, hot zone size, vacuum level, atmosphere, cooling water and load material.
How does it compare with other High Temperature Furnaces variants?
Choose a high-temperature furnace only when the process genuinely needs 1400 C or above, since cost, element life and atmosphere requirements rise steeply with temperature. Decide the atmosphere first: air, inert gas, vacuum or reducing, because elements and insulation depend on it. Then set the maximum temperature and hot zone size from the sample and crucible, and select the heating method, with resistance for clean work and induction for melting conductive charges. Confirm the temperature measurement method for the range, since thermocouples need type B or C and optical pyrometers are used above about 1800 C. Specify ramping capability, cooling, water supply and safety protection.
Full specifications
| Hot zone size | 150×150×250 to 500×500×800 mm |
|---|---|
| Maximum temperature | 2000–3000 C |
| Working vacuum | 1–100 Pa |
| Heating element | Graphite |
| Insulation | Graphite felt or rigid graphite |
| Temperature measurement | Type C thermocouple or pyrometer |
| Partial pressure | Argon controlled |
| Pumping system | Rotary-vane and roots |
| Heating power | 50–250 kW |
| Power supply | 380 V, 3-phase, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Graphitization of carbon materials
- Ultra-high-temperature sintering
- Silicon carbide and nitride processing
- Crystal growth from melt
- Advanced materials research
Key features
- Graphite elements and graphite felt insulation
- Working range 2000 to 3000 C
- Vacuum or inert-gas operation
- Water-cooled shell and electrodes
- Type C thermocouple or optical pyrometer
- Partial-pressure control with argon
Frequently asked questions about Graphite Element High-Temperature Furnace
Graphite oxidizes rapidly above about 500 C, consuming the elements and insulation and contaminating the load with carbon oxides. The furnace therefore operates under vacuum or inert gas, and a leak raises oxygen enough to damage the hot zone within a run.
Type C thermocouples cover to about 2300 C in inert conditions, and above that optical pyrometers or radiation thermometers view the crucible or load without contact. Readings are corrected for emissivity, which changes with material and surface.
Graphite, carbides, nitrides and many ceramics are processed cleanly, but materials that form carbides easily, such as titanium or tantalum, can react with the carbon environment. Oxide ceramics may also be reduced, so compatibility should be checked.
Standard high-temperature furnaces reach 1400 to 1800 C with silicon carbide or molybdenum disilicide elements. Graphite or tungsten hot zones under vacuum or inert gas extend the range to 2200 to 3000 C, but they cannot operate in air.
Graphite oxidizes rapidly in air above about 500 C, losing mass and contaminating the sample. Under vacuum or inert gas such as argon, graphite elements and insulation remain stable to well above 2000 C, which is why they dominate ultra-high-temperature work.
Induction heating suits melting conductive charges and heating a susceptor rapidly, because energy couples directly into the material or crucible. Resistance heating gives more uniform, controllable heating of a chamber and is preferred for sintering and heat treatment.
Related models