High-Pressure Cell Disruptor

高压细胞破碎仪

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Disruption pressure500–1,200 bar
Throughput1 L/h–200 L/h
Minimum sample volume5–20 mL
Number of passes1–8
Temperature controlRefrigerated feed, 4–10 °C
Typical disruption efficiencyUp to about 95 %
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-051, ISO 13320

What is the High-Pressure Cell Disruptor?

A high-pressure cell disruptor uses 500 to 1,200 bar to rupture bacteria, yeast and mammalian cells for intracellular protein, nucleic acid or organelle recovery. It is common in bioprocess development and structural biology.

What is the High-Pressure Cell Disruptor?

A high-pressure cell disruptor uses 500 to 1,200 bar to rupture bacteria, yeast and mammalian cells for intracellular protein, nucleic acid or organelle recovery. It is common in bioprocess development and structural biology.

Overview

The high-pressure cell disruptor applies the same valve principle as a homogenizer but is optimized for cell suspensions. A single or dual piston pump pressurizes the chilled cell slurry, and rapid decompression through the valve causes cells to rupture. Pressures of 500 to 1,200 bar and multiple passes give high disruption efficiency, and cooling or a refrigerated feed vessel protects proteins and organelles. Throughput ranges from a few milliliters to hundreds of liters per hour, covering laboratory and pilot bioprocess work. The passage is often temperature-controlled, and some models incorporate a cooling coil immediately after the valve. A key operating parameter is the pressure, because too high a pressure can damage sensitive proteins. The instrument complements bead mills and sonicators, and is valued for its scalability and ability to process large volumes continuously.

How does it work?

A high-pressure homogenizer uses a positive-displacement piston pump to pressurize the sample, then forces it through a narrow valve or interaction chamber. As the fluid passes the valve seat, velocity rises sharply and pressure drops, creating intense shear, turbulence and cavitation that break droplets and cells. In a two-stage design a second valve at lower pressure further refines the particle size distribution and reduces recoalescence. Product temperature rises by roughly 2 to 3 °C per 100 bar, so jacketed heat exchangers or ice cooling control the outlet temperature. Main components are the feed hopper or reservoir, pistons and seals, the valve assembly with wear-resistant seats, a pressure gauge, and the cooling circuit. Operating pressure, number of passes, valve geometry and temperature determine the achievable droplet size, often in the 50 to 500 nm range.

What are the key features?

  • Disruption pressure of 500–1,200 bar with multiple passes
  • Refrigerated or jacketed feed vessel for protein protection
  • Flow-through design for continuous large-volume processing
  • Single or dual piston pump with pressure control
  • Cooling coil after the valve to limit heat damage
  • Throughput from a few mL to hundreds of L per hour

What are the technical specifications?

A typical high-pressure cell disruptor configuration offers disruption pressure of 500–1,200 bar, throughput of 1 L/h–200 L/h, minimum sample volume of 5–20 mL, number of passes of 1–8, temperature control of Refrigerated feed, 4–10 °C and typical disruption efficiency of Up to about 95 %. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The High-Pressure Cell Disruptor is used in bacterial and yeast cell disruption, recombinant protein recovery, intracellular enzyme extraction, vaccine antigen preparation and organelle isolation. Across the wider High-Pressure Homogenizers class, laboratories also deploy it for nanoemulsion and liposome preparation, cell disruption for protein and nucleic acid recovery and pharmaceutical suspension particle size reduction.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-051, ISO 13320, EN ISO 12100 and GB 4793.1. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the unit on a level, rigid surface and allow access to the valve, seals and cooling lines. Prime the system before pressurizing to avoid dry running, which damages pistons and seals. Inspect and replace valve seats, O-rings and piston seals on a schedule, because wear shifts particle size. Clean and flush immediately after use; for biological work, validate a cleaning protocol that removes residues between products. Follow IEC 61010-1 for electrical safety and the local pressure equipment rules. Never open the valve assembly while the system is pressurized. Record pressure, passes, temperature and results so that batches can be reproduced, and verify performance with particle size analysis before release.

How do I select the right High-Pressure Cell Disruptor?

Choose a high-pressure cell disruptor when you need scalable, continuous disruption of cell slurries and want to avoid the heat and bead handling of other methods. Confirm pressure, throughput, cooling and minimum volume. In the RFQ, state cell type, concentration, target protein and process temperature.

How does it compare with other High-Pressure Homogenizers variants?

Select first by working pressure and throughput, because these set the achievable particle size and the batch time. Nanoemulsions and liposomes usually need 1,000 to 1,500 bar, while cell disruption often works at 500 to 1,000 bar. Match the machine size to batch volume: benchtop units for 10 to 500 mL, pilot units for 1 to 50 L, and production units above that. Choose the valve or interaction chamber geometry for your application, and whether one or two stages are needed. Confirm wetted materials such as 316L stainless steel, ceramic or diamond for abrasive samples, and the ability to autoclave or steam-in-place where sterility matters. Specify cooling, number of passes, pressure control and data logging in the request.

Full specifications

Full specifications
Disruption pressure500–1,200 bar
Throughput1 L/h–200 L/h
Minimum sample volume5–20 mL
Number of passes1–8
Temperature controlRefrigerated feed, 4–10 °C
Typical disruption efficiencyUp to about 95 %
Wetted material316L stainless steel
Valve seat materialTungsten carbide or ceramic
Power supply380 V three-phase

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Bacterial and yeast cell disruption
  • Recombinant protein recovery
  • Intracellular enzyme extraction
  • Vaccine antigen preparation
  • Organelle isolation

Key features

  • Disruption pressure of 500–1,200 bar with multiple passes
  • Refrigerated or jacketed feed vessel for protein protection
  • Flow-through design for continuous large-volume processing
  • Single or dual piston pump with pressure control
  • Cooling coil after the valve to limit heat damage
  • Throughput from a few mL to hundreds of L per hour

Frequently asked questions about High-Pressure Cell Disruptor

Most bacteria disrupt at 800 to 1,200 bar with two to four passes. Yeast needs higher pressure or a pre-treatment such as enzymatic lysis because of its thicker cell wall.