Multi-Parameter Tablet Tester (Hardness, Thickness, Diameter)
多参数片剂测试仪(硬度、厚度、直径)
- SKU HAT-0003
- Hardness Testers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Hardness range | 0–500 N |
|---|---|
| Hardness resolution | 0.1 N |
| Thickness range | 0–25 mm |
| Thickness resolution | 0.01 mm |
| Thickness accuracy | ±0.03 mm |
| Diameter range | 2–30 mm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1217>, Ph. Eur. 2.9.8, USP <1216>
What is the Multi-Parameter Tablet Tester (Hardness, Thickness, Diameter)?
A multi-parameter tablet tester measures hardness, thickness and diameter on the same tablet in a single sequence, often with an added weighing module. It is chosen by laboratories that want complete physical profiles of each tablet sampled and reduced handling time.
What is the Multi-Parameter Tablet Tester (Hardness, Thickness, Diameter)?
A multi-parameter tablet tester measures hardness, thickness and diameter on the same tablet in a single sequence, often with an added weighing module. It is chosen by laboratories that want complete physical profiles of each tablet sampled and reduced handling time.
Overview
The tester combines a motorized hardness jaw with a precision linear encoder or LVDT that measures the tablet dimension between the jaws before breaking. Thickness is read as the jaw gap, typically to 0.01 mm resolution, and diameter is measured by rotating the tablet or by a second measurement axis. Hardness is then determined from load cell force, and all results are stored per tablet. Adding an integrated balance provides weight to 0.1 mg, and the software can compute tensile strength from hardness, thickness and diameter, for round tablets using the classical formula 2F/(πDH). A feeder may load tablets sequentially for unattended sample sets of 20 or more. Output includes mean, standard deviation, RSD and charts, which are valuable for compression force and press validation. The instrument reduces transcription errors and analysis time compared with separate devices.
How does it work?
A hardness tester compresses a tablet diametrically between a stationary anvil and a moving jaw while a load cell records force. Force rises until the tablet fractures, and the peak value is reported as breaking force in newtons (or kgf, SCU). Manual designs use a spring or screw; motorized testers drive the jaw at a constant rate of typically 0.5–3 mm/s for operator-independent results. Multi-parameter testers add a displacement sensor to measure thickness and diameter, and some add a balance for weight. Tensile strength for flat round tablets equals 2F/(πDH), which normalizes hardness for size. Hardness depends on compression force, binder, moisture content and tablet geometry. The load cell is calibrated against traceable force standards per ISO 7500-1, and the loading rate and tablet orientation must be fixed in the method to ensure comparability.
What are the key features?
- Measures hardness, thickness and diameter on each tablet
- Optional balance module with 0.1 mg readability
- Tensile strength calculation from breaking force and dimensions
- Automatic tablet feeder for up to 20 or more units
- Statistics and charts for process trending
- LIMS or printer output for GMP records
What are the technical specifications?
A typical multi-parameter tablet tester (hardness, thickness, diameter) configuration offers hardness range of 0–500 N, hardness resolution of 0.1 N, thickness range of 0–25 mm, thickness resolution of 0.01 mm, thickness accuracy of ±0.03 mm and diameter range of 2–30 mm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Multi-Parameter Tablet Tester (Hardness, Thickness, Diameter) is used in tablet press validation, QC batch release, formulation development and tensile-strength characterization. Across the wider Hardness Testers class, laboratories also deploy it for tablet compression control, QC release testing and formulation development.
Which standards and certifications apply?
Relevant standards and methods include USP <1217>, Ph. Eur. 2.9.8, USP <1216>, ISO 7500-1, ASTM E4, ChP 0931 and USP <905>. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the tester on a stable bench away from vibration. Verify force with traceable weights or a reference load cell at installation and at least annually, plus after overload events. Clean anvils and jaws to remove powder that can affect contact, and inspect them for wear. Use consistent tablet orientation and loading speed, test at least ten tablets, and allow tablets to equilibrate to room temperature and humidity. Record units clearly, because kgf and N are both used. For regulated laboratories, include the tester in IQ/OQ and calibration schedules and maintain audit-trail records for electronic data.
How do I select the right Multi-Parameter Tablet Tester (Hardness, Thickness, Diameter)?
Choose a multi-parameter tester when hardness, thickness and dimensions are all reported and when transcription errors or handling time are concerns. Specify measurement ranges, balance option, feeder capacity, tensile strength calculations and data integration. A pure hardness tester is enough if only breaking force is required.
How does it compare with other Hardness Testers variants?
Decide first whether you need manual spot checks or repeatable QC data. Manual testers suit press set-up and teaching; motorized digital testers suit release and validation work with constant loading speed and records. Choose a multi-parameter tester when thickness, diameter, weight and tensile strength are also required, and an automated system for high sample volume or press integration. For boluses and large tablets specify a 1000 N or greater capacity. Key parameters are force range, resolution (0.1 N for small tablets), accuracy, loading speed, tablet diameter range, statistics, data output and compatibility with 21 CFR Part 11 if regulated. Verify that the supplier provides force calibration certificates traceable to national standards.
Full specifications
| Hardness range | 0–500 N |
|---|---|
| Hardness resolution | 0.1 N |
| Thickness range | 0–25 mm |
| Thickness resolution | 0.01 mm |
| Thickness accuracy | ±0.03 mm |
| Diameter range | 2–30 mm |
| Weight range (option) | 0–220 g, 0.1 mg |
| Throughput | about 6–10 tablets per minute |
| Data output | USB, Ethernet, printer, LIMS |
| Power supply | 220 V AC, 50/60 Hz, 80 W |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Tablet press validation
- QC batch release
- Formulation development
- Tensile-strength characterization
Key features
- Measures hardness, thickness and diameter on each tablet
- Optional balance module with 0.1 mg readability
- Tensile strength calculation from breaking force and dimensions
- Automatic tablet feeder for up to 20 or more units
- Statistics and charts for process trending
- LIMS or printer output for GMP records
Frequently asked questions about Multi-Parameter Tablet Tester (Hardness, Thickness, Diameter)
Hardness depends on tablet thickness and geometry. Measuring both on the same tablet allows tensile strength to be calculated, which normalizes for size differences and aids press comparisons.
For flat round tablets, tensile strength equals 2F divided by πDH, where F is breaking force, D is diameter and H is thickness. Other shapes need different models.
Yes, with orientation fixtures and adjustable anvils. Methods should define whether force is applied across the score or perpendicular to it and be kept consistent.
It measures the force needed to fracture a tablet across its diameter, reported as breaking force in newtons. The value indicates mechanical strength for packaging, coating and handling.
It depends on the product. Uncoated immediate-release tablets often range from 40 to 100 N, while larger or extended-release tablets may exceed 150 N. Limits are set during development.
Testing ten tablets per sample is common practice, reporting mean, standard deviation and range. Validation studies may use 20 or more tablets.