Glass Packed-Bed Bioreactor
玻璃填充床生物反应器
- SKU GLB-0004
- Glass Bioreactors
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Bed volume | 0.2–10 L |
|---|---|
| Carrier type | Porous glass, ceramic or polymer beads |
| Surface area per volume | Up to several thousand cm²/L |
| Flow rate | 0.5–20 L/h recirculation |
| Temperature range | Ambient +5 to 45 °C |
| pH control | 6.5–8.0, ±0.05 |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 9001, USP <87>, USP <88>
What is the Glass Packed-Bed Bioreactor?
A glass packed-bed bioreactor grows adherent cells on carriers held in a transparent column while medium flows through. It provides a high surface area per volume and low shear for anchorage-dependent cells.
What is the Glass Packed-Bed Bioreactor?
A glass packed-bed bioreactor grows adherent cells on carriers held in a transparent column while medium flows through. It provides a high surface area per volume and low shear for anchorage-dependent cells.
Overview
A glass packed-bed bioreactor consists of a transparent column filled with carriers such as porous glass, ceramic or polymer beads, or fibrous matrices, through which culture medium is recirculated. Adherent cells attach to the carrier surfaces and grow in a fixed bed, so the culture is protected from shear and the surface area per unit volume is much higher than in a flat flask. A reservoir supplies medium, and the loop includes a pump, a gas exchanger, pH and dissolved oxygen probes and often a sampling port. Fresh medium is added and spent medium removed to control nutrient levels. The transparent column allows operators to see channeling, gas bubbles and biomass accumulation. Packed beds are used for vaccine and antibody production from anchorage-dependent cells, and they require attention to flow distribution and to harvesting cells or product from the bed.
How does it work?
A glass bioreactor uses a transparent vessel so that mixing, foam, color and biomass can be observed directly during culture. Borosilicate glass resists thermal shock and most cleaning agents, and a detachable headplate carries the agitator, sparger, probes and ports. Temperature is controlled by a water jacket, a heating blanket or a water bath, pH is adjusted by dosing acid, base or carbon dioxide, and dissolved oxygen is held by adjusting gas flow, oxygen fraction or agitation speed. Mixing may be by impeller, by gas-driven circulation in airlift or bubble column designs, or by gentle rocking for sensitive cells. Glass vessels are usually sterilized in an autoclave, which limits their practical size, but they allow rapid changes of impeller, sparger and sensor configuration between experiments.
What are the key features?
- Transparent column packed with carriers
- High surface area per unit volume
- Low shear for adherent cells
- Recirculation loop with gas exchange
- Visible bed for channeling checks
What are the technical specifications?
A typical glass packed-bed bioreactor configuration offers bed volume of 0.2–10 L, carrier type of Porous glass, ceramic or polymer beads, surface area per volume of Up to several thousand cm²/L, flow rate of 0.5–20 L/h recirculation, temperature range of Ambient +5 to 45 °C and pH control of 6.5–8.0, ±0.05. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Glass Packed-Bed Bioreactor is used in anchorage-dependent cell culture, vaccine production research, monoclonal antibody production and tissue engineering studies. Across the wider Glass Bioreactors class, laboratories also deploy it for process development and scale-down models, cell culture optimization and microbial fermentation studies.
Which standards and certifications apply?
Relevant standards and methods include ISO 9001, USP <87>, USP <88>, IEC 61010-1, ISO 11133 and GB/T 150. Certification candidates for this model are CE, ISO 9001 manufacturing and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Inspect glass for chips or cracks before each run, because even a small flaw can fail under autoclaving or pressure. Assemble the headplate carefully so that probes do not touch the impeller, and check that all ports are sealed. Calibrate pH and dissolved oxygen probes before sterilization and confirm they survive the cycle. Use a protective shield or cabinet where pressure or a fragile vessel could present a hazard. Clean glass promptly to avoid baked-on residue, and avoid strong alkalis that etch the surface over time. Replace gaskets and O-rings on a schedule, and keep a log of sterilization cycles for each vessel and headplate.
How do I select the right Glass Packed-Bed Bioreactor?
Choose a packed-bed bioreactor for adherent cells when high surface area and low shear matter more than direct cell sampling. In an RFQ specify bed volume, carrier type and size, flow rate, gas exchange, loop components and the harvesting approach.
How does it compare with other Glass Bioreactors variants?
Choose a glass bioreactor when you need to see the culture, change configuration quickly or work at small volumes. Select the mixing principle from the cell type and oxygen demand: stirred designs give flexible power input, airlift and bubble columns suit shear-sensitive cultures, packed-bed designs suit adherent cells on carriers, and photobioreactors suit photosynthetic organisms. Confirm the working volume and headspace, the number and type of ports, and whether the headplate can accommodate the probes and feeds you need. Check the temperature control method, since a water jacket gives more uniform heating than a blanket, and confirm how the vessel is sterilized. Verify that materials and connectors suit autoclaving and that spare headplates and vessels allow parallel or rapid sequential experiments.
Full specifications
| Bed volume | 0.2–10 L |
|---|---|
| Carrier type | Porous glass, ceramic or polymer beads |
| Surface area per volume | Up to several thousand cm²/L |
| Flow rate | 0.5–20 L/h recirculation |
| Temperature range | Ambient +5 to 45 °C |
| pH control | 6.5–8.0, ±0.05 |
| Dissolved oxygen control | Via gas exchanger |
| Sterilization | Autoclave assembly |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Anchorage-dependent cell culture
- Vaccine production research
- Monoclonal antibody production
- Tissue engineering studies
Key features
- Transparent column packed with carriers
- High surface area per unit volume
- Low shear for adherent cells
- Recirculation loop with gas exchange
- Visible bed for channeling checks
Frequently asked questions about Glass Packed-Bed Bioreactor
Adherent cells need a surface to attach to, and productivity scales with available area. A packed bed packs a large area into a small volume, so it can produce more cells or product than a flask or roller bottle of comparable working volume.
Channeling, where flow favors some paths and starves others, and gas pockets trapped in the bed are common issues. Flow rate, carrier size and packing method are adjusted to limit these, and the transparent column helps operators see developing problems.
For secreted products, the recirculating medium or the perfusate is harvested and purified downstream. For cells, the bed may be emptied and cells released by enzymatic treatment, which is laborious, so many processes keep cells on the carrier and collect only secreted product.
It cultivates cells or microorganisms at small scale while allowing direct observation. Uses include process development, scale-down modelling of production vessels, cell culture optimization, algae research and teaching, where visibility and quick configuration changes are valuable.
Glass is used mainly at bench scale, commonly up to about 10 to 20 litres, because autoclaving and pressure ratings limit size. Large volumes use stainless steel or single-use bags, and glass also needs care to avoid breakage during handling and sterilization.
Most glass vessels are dismantled and autoclaved together with the headplate, probes, lines and filters. Some designs allow in-situ sterilization with steam for larger glass vessels, but the pressure and thermal limits of glass must be respected.
Related models