Lab Manufacturers China
Automatic Disintegration Tester with Endpoint Detection — product photo

Automatic Disintegration Tester with Endpoint Detection

带终点检测的自动崩解时限测试仪

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Number of baskets1 or 2
Tubes per basket6
Detection methodOptical / conductivity
Time resolution1 s
Stroke length55 ± 2 mm
Frequency29–32 cycles/min
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <701>, Ph. Eur. 2.9.1, JP 6.09

What is the Automatic Disintegration Tester with Endpoint Detection?

An automatic disintegration tester with endpoint detection uses optical or conductivity sensors to identify when each tablet clears the mesh and records the time without operator observation. It reduces subjectivity and supports documented results.

What is the Automatic Disintegration Tester with Endpoint Detection?

An automatic disintegration tester with endpoint detection uses optical or conductivity sensors to identify when each tablet clears the mesh and records the time without operator observation. It reduces subjectivity and supports documented results.

Overview

This variant adds sensors that monitor each tube for the moment the dosage form has fully disintegrated. Optical versions use a light beam or camera across the mesh, while conductivity versions detect contact of the dosage form with the disc. The software records the individual disintegration time for each of the six tubes and reports the mean, minimum and maximum. Because the endpoint is sensor-based, results are more consistent between operators, which is important for dark, opaque or coated products where visual detection is difficult. The instrument retains the standard stroke and frequency, and the sensors should be verified with reference samples because suspended residue or bubbles can cause false readings. Software often supports user levels, printed reports and data export.

How does it work?

A disintegration tester consists of a basket-rack assembly, a motor-driven mechanism, and a thermostatic bath. The basket-rack holds six transparent tubes with a stainless steel mesh (typically 2.0 mm aperture) at the bottom. The mechanism moves the assembly vertically through a distance of 53 to 57 mm at 29 to 32 cycles per minute, while the immersion fluid, usually water, 0.1 M hydrochloric acid or phosphate buffer, is held at 37 ± 2 °C. A dosage unit is placed in each tube, optionally with a perforated disc that adds gentle mechanical action. The test ends when no residue, other than fragments of insoluble coating or capsule shell, remains on the mesh. The operator records the time of complete disintegration, which is compared with the monograph limit, commonly 15 to 60 minutes.

What are the key features?

  • Per-tube endpoint detection by optical or conductivity sensors
  • Individual times with mean, minimum and maximum in the report
  • Less operator-to-operator variation for opaque products
  • Standard 55 mm stroke at about 30 cycles per minute
  • Software with user levels and data export

What are the technical specifications?

A typical automatic disintegration tester with endpoint detection configuration offers number of baskets of 1 or 2, tubes per basket of 6, detection method of Optical / conductivity, time resolution of 1 s, stroke length of 55 ± 2 mm and frequency of 29–32 cycles/min. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Automatic Disintegration Tester with Endpoint Detection is used in opaque or coated tablet testing, GMP release testing with documented results, formulation screening and contract laboratories. Across the wider Disintegration Testers class, laboratories also deploy it for tablet and capsule release testing, formulation development and stability studies.

Which standards and certifications apply?

Relevant standards and methods include USP <701>, Ph. Eur. 2.9.1, JP 6.09 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the tester on a stable bench with a level water bath and access to clean water. Calibrate stroke length, frequency and temperature at installation and at defined intervals, using an independent thermometer and a ruler or gauge. Replace the immersion medium frequently and clean tubes, mesh and discs to prevent residue build-up that blocks the mesh. Use deaerated medium if required by the method, because air bubbles can lift tablets. Check the mesh for distortion, since a damaged screen changes the test outcome. Record lot numbers of medium, bath temperature and operator. Under GMP, document IQ, OQ and PQ, and verify the system with a suitable reference tablet where practical.

How do I select the right Automatic Disintegration Tester with Endpoint Detection?

Choose this variant when visual detection is unreliable or when consistent, documented endpoints are required. Standard models remain adequate for clear, rapidly disintegrating products. In an RFQ, state the detection principle, time resolution, number of baskets, software features and the sample types to be verified.

How does it compare with other Disintegration Testers variants?

Choose according to sample throughput, temperature control and data requirements. A two-basket tester allows two test groups in parallel and is often chosen where stage testing is performed, for example acid stage followed by buffer stage for enteric products. Single-basket units are adequate for routine release. Confirm stroke length, frequency and basket dimensions against the target pharmacopoeia, and check that the bath can hold 37 °C within ±1 °C. Automatic endpoint detection reduces subjectivity, which matters for opaque or colored dosage forms where visual judgment is difficult. Laboratories under GMP should look for software with audit trails and probe-based temperature recording. A portable or benchtop size matters if bench space is limited, and a bath with a cooling or sealed circulation option helps in warm climates.

Full specifications

Full specifications
Number of baskets1 or 2
Tubes per basket6
Detection methodOptical / conductivity
Time resolution1 s
Stroke length55 ± 2 mm
Frequency29–32 cycles/min
Bath temperature rangeAmbient +5 to 45 °C
Temperature accuracy± 0.5 °C
Data outputUSB / printer
Power supply220 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Opaque or coated tablet testing
  • GMP release testing with documented results
  • Formulation screening
  • Contract laboratories

Key features

  • Per-tube endpoint detection by optical or conductivity sensors
  • Individual times with mean, minimum and maximum in the report
  • Less operator-to-operator variation for opaque products
  • Standard 55 mm stroke at about 30 cycles per minute
  • Software with user levels and data export

Frequently asked questions about Automatic Disintegration Tester with Endpoint Detection

Optical detection depends on contrast changes at the mesh, so dark or colored tablets can be detected, but sensor sensitivity must be verified with your own products. Conductivity-based detection is less affected by color.

Request a quotation for the Automatic Disintegration Tester with Endpoint Detection

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.