Key specifications
| Number of baskets | 1 or 2 |
|---|---|
| Tubes per basket | 6 |
| Disc types | Standard and agitation |
| Stroke length | 55 ± 2 mm |
| Frequency | 29–32 cycles/min |
| Bath temperature range | Ambient +5 to 45 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <701>, Ph. Eur. 2.9.1, JP 6.09
What is the Disintegration Tester with Disc-Free Basket for Capsules and Soft Gels?
This disintegration tester variant is configured for capsules and soft gels, with optional discs and compatible medium handling. It suits laboratories testing gelatin or plant-based capsules and softgels, which behave differently from compressed tablets.
What is the Disintegration Tester with Disc-Free Basket for Capsules and Soft Gels?
This disintegration tester variant is configured for capsules and soft gels, with optional discs and compatible medium handling. It suits laboratories testing gelatin or plant-based capsules and softgels, which behave differently from compressed tablets.
Overview
Capsules and soft gels disintegrate mainly by shell rupture and dissolution, so the test is sensitive to medium temperature, buoyancy and the use of a disc. This variant provides the standard basket-rack assembly with a selection of discs, including those with and without agitation features, and tubes that accommodate the lighter, buoyant units. The water bath is tuned for tight temperature control at 37 °C because gelatin shell behavior changes sharply with small temperature shifts. Some models offer a longer test timer, since soft gel limits can reach 30 minutes or more, and medium options such as water and simulated gastric fluid. The hardware is otherwise similar to standard units, but capsule-specific accessories ensure repeatable results for floating units.
How does it work?
A disintegration tester consists of a basket-rack assembly, a motor-driven mechanism, and a thermostatic bath. The basket-rack holds six transparent tubes with a stainless steel mesh (typically 2.0 mm aperture) at the bottom. The mechanism moves the assembly vertically through a distance of 53 to 57 mm at 29 to 32 cycles per minute, while the immersion fluid, usually water, 0.1 M hydrochloric acid or phosphate buffer, is held at 37 ± 2 °C. A dosage unit is placed in each tube, optionally with a perforated disc that adds gentle mechanical action. The test ends when no residue, other than fragments of insoluble coating or capsule shell, remains on the mesh. The operator records the time of complete disintegration, which is compared with the monograph limit, commonly 15 to 60 minutes.
What are the key features?
- Discs with and without agitation features for floating capsules
- Tight 37 °C temperature control for gelatin shells
- Extended timer for soft gel limits of 30 minutes or more
- Tubes sized for capsules and soft gels
- Standard pharmacopoeial stroke and frequency
What are the technical specifications?
A typical disintegration tester with disc-free basket for capsules and soft gels configuration offers number of baskets of 1 or 2, tubes per basket of 6, disc types of Standard and agitation, stroke length of 55 ± 2 mm, frequency of 29–32 cycles/min and bath temperature range of Ambient +5 to 45 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Disintegration Tester with Disc-Free Basket for Capsules and Soft Gels is used in hard gelatin capsule testing, soft gel product testing, vegetarian capsule evaluation and supplement manufacturing. Across the wider Disintegration Testers class, laboratories also deploy it for tablet and capsule release testing, formulation development and stability studies.
Which standards and certifications apply?
Relevant standards and methods include USP <701>, Ph. Eur. 2.9.1, JP 6.09 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the tester on a stable bench with a level water bath and access to clean water. Calibrate stroke length, frequency and temperature at installation and at defined intervals, using an independent thermometer and a ruler or gauge. Replace the immersion medium frequently and clean tubes, mesh and discs to prevent residue build-up that blocks the mesh. Use deaerated medium if required by the method, because air bubbles can lift tablets. Check the mesh for distortion, since a damaged screen changes the test outcome. Record lot numbers of medium, bath temperature and operator. Under GMP, document IQ, OQ and PQ, and verify the system with a suitable reference tablet where practical.
How do I select the right Disintegration Tester with Disc-Free Basket for Capsules and Soft Gels?
Select this variant when capsules and soft gels make up most of your testing. A standard model can be used with capsule discs if volumes are low. In an RFQ, specify disc types, temperature accuracy, maximum timer, medium compatibility and the capsule monographs to be tested.
How does it compare with other Disintegration Testers variants?
Choose according to sample throughput, temperature control and data requirements. A two-basket tester allows two test groups in parallel and is often chosen where stage testing is performed, for example acid stage followed by buffer stage for enteric products. Single-basket units are adequate for routine release. Confirm stroke length, frequency and basket dimensions against the target pharmacopoeia, and check that the bath can hold 37 °C within ±1 °C. Automatic endpoint detection reduces subjectivity, which matters for opaque or colored dosage forms where visual judgment is difficult. Laboratories under GMP should look for software with audit trails and probe-based temperature recording. A portable or benchtop size matters if bench space is limited, and a bath with a cooling or sealed circulation option helps in warm climates.
Full specifications
| Number of baskets | 1 or 2 |
|---|---|
| Tubes per basket | 6 |
| Disc types | Standard and agitation |
| Stroke length | 55 ± 2 mm |
| Frequency | 29–32 cycles/min |
| Bath temperature range | Ambient +5 to 45 °C |
| Temperature accuracy | ± 0.3 °C |
| Timer range | 0–99 min |
| Suitable media | Water, SGF, buffers |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Hard gelatin capsule testing
- Soft gel product testing
- Vegetarian capsule evaluation
- Supplement manufacturing
Key features
- Discs with and without agitation features for floating capsules
- Tight 37 °C temperature control for gelatin shells
- Extended timer for soft gel limits of 30 minutes or more
- Tubes sized for capsules and soft gels
- Standard pharmacopoeial stroke and frequency
Frequently asked questions about Disintegration Tester with Disc-Free Basket for Capsules and Soft Gels
Capsules and soft gels often float, so a disc keeps them submerged and adds mild mechanical action. Whether a disc is used is defined in the monograph, and using it or not can change the result noticeably.
Gelatin shells soften quickly near 37 °C, so the temperature should stay within ±1 °C, and within ±0.5 °C where practicable. Verify with an independent calibrated thermometer during qualification.
Yes, provided the correct discs and medium are used for each product and the tester meets pharmacopoeial parameters. A capsule-oriented tester simply supplies more accessories and tighter temperature control.
A disintegration tester is a pharmacopoeial apparatus that moves tablets or capsules up and down in a heated fluid and measures how long they take to break apart. It is used as a quick quality test for oral solid dosage forms.
The standard temperature is 37 ± 2 °C, representing body temperature. The bath must hold this range throughout the test, and many laboratories check it with a calibrated independent thermometer rather than relying solely on the display.
Disintegration measures when a dosage form breaks into particles, while dissolution measures the rate and extent to which the drug enters solution. A tablet can disintegrate quickly and still dissolve slowly, so the two tests are complementary.
Related models