Two-Bed Deionizer
双床去离子器
- SKU DEI-0006
- Deionizers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- Material conformity (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Resistivity | 1–10 MΩ·cm |
|---|---|
| Flow rate | 5–100 L/min |
| Capacity per cycle | 2,000–100,000 L |
| Columns | 2 (cation and anion) |
| Regenerant | HCl and NaOH |
| Vessel material | FRP or stainless steel |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 3696, CLSI GP40, USP <643>
What is the Two-Bed Deionizer?
A two-bed deionizer uses separate cation and anion columns, making regeneration straightforward and reducing operating cost. It is used where moderate purity and repeated, low-cost regeneration are preferred over the highest possible resistivity.
What is the Two-Bed Deionizer?
A two-bed deionizer uses separate cation and anion columns, making regeneration straightforward and reducing operating cost. It is used where moderate purity and repeated, low-cost regeneration are preferred over the highest possible resistivity.
Overview
The two-bed deionizer places strong acid cation resin in one column and strong base anion resin in another, in series. Cations are exchanged first, and the acidic water that results drives the anion exchange efficiently, so the design reaches resistivity of about 1 to 10 megohm-centimeters. Because the resins are already separated, regeneration with acid and caustic is straightforward and does not require the density separation needed for a mixed bed, which reduces labor and chemical consumption. Two-bed systems handle higher ionic loads and larger volumes than mixed beds and are common as bulk deionization before a mixed-bed polishing stage. A conductivity monitor tracks the outlet, and carbon filtration or reverse osmosis is usually placed upstream. The combination of a two-bed primary and a mixed-bed polisher is a standard arrangement for producing high-purity water economically.
How does it work?
A deionizer passes water through beds of ion exchange resin. Cation resin exchanges positively charged ions such as calcium, magnesium and sodium for hydrogen ions, and anion resin exchanges negatively charged ions such as chloride, sulfate and bicarbonate for hydroxide ions. The hydrogen and hydroxide combine to form water, so dissolved salts are removed without adding anything to the water. Mixed-bed resin places both types together and gives the highest resistivity, while two-bed systems use separate columns and are easier to regenerate. Resin capacity is finite: as sites become exhausted, the treated water conductivity rises. Exhaustion is detected by a conductivity or resistivity monitor, and the resin is then replaced or regenerated with acid and caustic. Prefilters and carbon protect the resin from particles, chlorine and organics.
What are the key features?
- Separate cation and anion columns in series
- Resistivity of about 1–10 MΩ·cm
- Straightforward regeneration without density separation
- Handles higher ionic loads than mixed beds
- Conductivity monitor on the outlet
- Often paired with a mixed-bed polisher
What are the technical specifications?
A typical two-bed deionizer configuration offers resistivity of 1–10 MΩ·cm, flow rate of 5–100 L/min, capacity per cycle of 2,000–100,000 L, columns of 2 (cation and anion), regenerant of HCl and NaOH and vessel material of FRP or stainless steel. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Two-Bed Deionizer is used in bulk deionization before polishing, high-volume Type II water, industrial and pilot water treatment, boiler and cooling feed and laboratory central supply. Across the wider Deionizers class, laboratories also deploy it for type II water for general analysis, reagent and buffer preparation and polishing after reverse osmosis.
Which standards and certifications apply?
Relevant standards and methods include ISO 3696, CLSI GP40, USP <643>, IEC 61010-1 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and Material conformity; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Feed the deionizer with water that is free of chlorine and particles, because chlorine oxidizes resin and particles block flow. Do not let the resin bed run dry, and keep it wet during storage to avoid shrinkage and channeling. Monitor resistivity on a temperature-compensated basis, and plan replacement or regeneration before exhaustion so quality never falls below specification. When regenerating with acid and caustic, use proper personal protection, neutralize the waste and dispose of it according to local rules. Keep the distribution loop short and recirculating to prevent biofilm, and sanitize where microbiology matters. Follow IEC 61010-1 for electrical safety and record resistivity, volumes and service dates so that resin life can be predicted.
How do I select the right Two-Bed Deionizer?
Choose a two-bed system for high ionic loads and large volumes where regeneration cost and simplicity matter, and add a mixed-bed polisher if the highest resistivity is required. For small volumes, cartridges are simpler. In the RFQ, state flow, ionic load and purity target.
How does it compare with other Deionizers variants?
Decide what feed water the deionizer will treat, because resin life depends strongly on the incoming ionic load. If the feed is tap water, a reverse osmosis stage ahead of the deionizer greatly extends resin life; if the feed is already purified, a polishing cartridge may be all that is needed. Choose mixed-bed resin for the highest resistivity and two-bed or regenerable designs where operating cost and regeneration matter. Match flow rate and cartridge capacity to your daily volume, and check whether the system shuts down at resin exhaustion or continues to deliver lower-quality water. Consider whether you need a resistivity monitor with temperature compensation, a recirculation pump to keep the loop fresh, and UV or ultrafiltration for organic and microbial control. Compare consumable cost, regeneration frequency and disposal requirements before choosing.
Full specifications
| Resistivity | 1–10 MΩ·cm |
|---|---|
| Flow rate | 5–100 L/min |
| Capacity per cycle | 2,000–100,000 L |
| Columns | 2 (cation and anion) |
| Regenerant | HCl and NaOH |
| Vessel material | FRP or stainless steel |
| Monitor | Conductivity with alarm |
| Upstream | Carbon or RO recommended |
| Power supply | 220–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Bulk deionization before polishing
- High-volume Type II water
- Industrial and pilot water treatment
- Boiler and cooling feed
- Laboratory central supply
Key features
- Separate cation and anion columns in series
- Resistivity of about 1–10 MΩ·cm
- Straightforward regeneration without density separation
- Handles higher ionic loads than mixed beds
- Conductivity monitor on the outlet
- Often paired with a mixed-bed polisher
Frequently asked questions about Two-Bed Deionizer
The resins are already in separate columns, so acid and caustic can be applied directly without separating mixed resin by density. This saves labor and reduces chemical waste.
About 1 to 10 megohm-centimeters, which suits general analytical work. For trace analysis and higher resistivity, add a mixed-bed polisher after the two beds.
Yes, carbon filtration to remove chlorine and, ideally, reverse osmosis to lower the ionic load. This protects the resin and extends the time between regenerations considerably.
A mixed-bed deionizer fed with low-ionic water can reach about 18.2 megohm-centimeters at 25 degrees Celsius, the practical limit for pure water. Feed quality and organic load determine actual performance.
A temperature-compensated resistivity or conductivity monitor shows the rise. Set an alarm at a threshold just below your specification, and replace or regenerate before quality falls out of range.
Small cartridge units are usually replaced, while larger systems with separate beds are regenerated with acid and caustic. Regeneration costs less per liter but needs chemicals, safety measures and waste handling.
Related models