Wall-Mounted Deionizer
壁挂式去离子器
- SKU DEI-0004
- Deionizers
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Resistivity | 10–18 MΩ·cm |
|---|---|
| Flow rate | 2–20 L/min |
| Cartridges | 1–4 |
| Feed quality | RO or distilled |
| Monitor | Resistivity with alarm |
| Recirculation | Optional pump |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 3696, CLSI GP40, USP <643>
What is the Wall-Mounted Deionizer?
A wall-mounted deionizer is installed permanently to supply deionized water to a laboratory or bench. It saves valuable bench space and delivers steady, monitored quality through a fixed outlet or short distribution loop.
What is the Wall-Mounted Deionizer?
A wall-mounted deionizer is installed permanently to supply deionized water to a laboratory or bench. It saves valuable bench space and delivers steady, monitored quality through a fixed outlet or short distribution loop.
Overview
The wall-mounted deionizer pairs a housing with one to four resin cartridges and a resistivity monitor, plumbed to a feed line and an outlet or distribution loop. Flow rates are typically 2 to 20 liters per minute, and resistivity is usually 10 to 18 megohm-centimeters from pre-purified feed. Wall mounting frees the bench and reduces the risk of accidental tipping, and a lockable or metered outlet can control use in shared facilities. Some units include a recirculation pump to keep water fresh in the loop and a UV lamp for organic control. Cartridge changes are done from the front, so service is quick. These systems are common in quality control and research laboratories that need a reliable point of use, and they are often paired with a reverse osmosis unit installed nearby.
How does it work?
A deionizer passes water through beds of ion exchange resin. Cation resin exchanges positively charged ions such as calcium, magnesium and sodium for hydrogen ions, and anion resin exchanges negatively charged ions such as chloride, sulfate and bicarbonate for hydroxide ions. The hydrogen and hydroxide combine to form water, so dissolved salts are removed without adding anything to the water. Mixed-bed resin places both types together and gives the highest resistivity, while two-bed systems use separate columns and are easier to regenerate. Resin capacity is finite: as sites become exhausted, the treated water conductivity rises. Exhaustion is detected by a conductivity or resistivity monitor, and the resin is then replaced or regenerated with acid and caustic. Prefilters and carbon protect the resin from particles, chlorine and organics.
What are the key features?
- Permanent wall installation with fixed outlet
- One to four resin cartridges with front access
- Flow rates of 2–20 L/min
- Resistivity of 10–18 MΩ·cm from purified feed
- Optional recirculation pump and UV lamp
- Lockable or metered outlet for shared use
What are the technical specifications?
A typical wall-mounted deionizer configuration offers resistivity of 10–18 MΩ·cm, flow rate of 2–20 L/min, cartridges of 1–4, feed quality of RO or distilled, monitor of Resistivity with alarm and recirculation of Optional pump. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Wall-Mounted Deionizer is used in laboratory point-of-use supply, quality control reagent water, shared facility metered outlet, feed to analytical instruments and glassware final rinse. Across the wider Deionizers class, laboratories also deploy it for type II water for general analysis, reagent and buffer preparation and polishing after reverse osmosis.
Which standards and certifications apply?
Relevant standards and methods include ISO 3696, CLSI GP40, USP <643>, IEC 61010-1 and ISO 9001. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Feed the deionizer with water that is free of chlorine and particles, because chlorine oxidizes resin and particles block flow. Do not let the resin bed run dry, and keep it wet during storage to avoid shrinkage and channeling. Monitor resistivity on a temperature-compensated basis, and plan replacement or regeneration before exhaustion so quality never falls below specification. When regenerating with acid and caustic, use proper personal protection, neutralize the waste and dispose of it according to local rules. Keep the distribution loop short and recirculating to prevent biofilm, and sanitize where microbiology matters. Follow IEC 61010-1 for electrical safety and record resistivity, volumes and service dates so that resin life can be predicted.
How do I select the right Wall-Mounted Deionizer?
Choose a wall-mounted unit for a fixed point of use with steady demand and limited bench space. For a portable option, choose a compact or portable deionizer. In the RFQ, state flow, resistivity, feed source, mounting and metering needs.
How does it compare with other Deionizers variants?
Decide what feed water the deionizer will treat, because resin life depends strongly on the incoming ionic load. If the feed is tap water, a reverse osmosis stage ahead of the deionizer greatly extends resin life; if the feed is already purified, a polishing cartridge may be all that is needed. Choose mixed-bed resin for the highest resistivity and two-bed or regenerable designs where operating cost and regeneration matter. Match flow rate and cartridge capacity to your daily volume, and check whether the system shuts down at resin exhaustion or continues to deliver lower-quality water. Consider whether you need a resistivity monitor with temperature compensation, a recirculation pump to keep the loop fresh, and UV or ultrafiltration for organic and microbial control. Compare consumable cost, regeneration frequency and disposal requirements before choosing.
Full specifications
| Resistivity | 10–18 MΩ·cm |
|---|---|
| Flow rate | 2–20 L/min |
| Cartridges | 1–4 |
| Feed quality | RO or distilled |
| Monitor | Resistivity with alarm |
| Recirculation | Optional pump |
| UV option | 254 nm, optional |
| Mounting | Wall bracket |
| Power supply | 100–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Laboratory point-of-use supply
- Quality control reagent water
- Shared facility metered outlet
- Feed to analytical instruments
- Glassware final rinse
Key features
- Permanent wall installation with fixed outlet
- One to four resin cartridges with front access
- Flow rates of 2–20 L/min
- Resistivity of 10–18 MΩ·cm from purified feed
- Optional recirculation pump and UV lamp
- Lockable or metered outlet for shared use
Frequently asked questions about Wall-Mounted Deionizer
It frees bench space, keeps the water path away from spills and reduces tripping risk. Front-access cartridges make routine replacement quick without moving the unit.
Yes, with a short distribution loop and a recirculation pump to keep water fresh. Long dead legs encourage biofilm, so keep the loop compact and circulate continuously.
It is advisable when the water is used for molecular biology or microbiology, because deionization does not remove microorganisms. The 254 nanometer lamp reduces microbial counts in the loop.
A mixed-bed deionizer fed with low-ionic water can reach about 18.2 megohm-centimeters at 25 degrees Celsius, the practical limit for pure water. Feed quality and organic load determine actual performance.
A temperature-compensated resistivity or conductivity monitor shows the rise. Set an alarm at a threshold just below your specification, and replace or regenerate before quality falls out of range.
Small cartridge units are usually replaced, while larger systems with separate beds are regenerated with acid and caustic. Regeneration costs less per liter but needs chemicals, safety measures and waste handling.
Related models