Skip to main content
Lab Manufacturers China
Automated Carbon Sulfur Analyzer with Autosampler — product photo

Automated Carbon Sulfur Analyzer with Autosampler

带自动进样器的自动碳硫分析仪

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Carbon range0.0001–6%
Sulfur range0.0001–0.35%
Autosampler capacity50–100 crucibles
Cycle time60–90 s per sample
Sample mass0.2–1 g
Carbon precision (RSD)≤0.5% at 0.1% C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E1019, ASTM E1941, ISO 15350

What is the Automated Carbon Sulfur Analyzer with Autosampler?

An automated carbon sulfur analyzer adds a crucible autosampler and robotic loading to an induction furnace system. It runs 50–100 samples unattended and is chosen by high-volume production and contract laboratories to reduce operator time and handling error.

What is the Automated Carbon Sulfur Analyzer with Autosampler?

An automated carbon sulfur analyzer adds a crucible autosampler and robotic loading to an induction furnace system. It runs 50–100 samples unattended and is chosen by high-volume production and contract laboratories to reduce operator time and handling error.

Overview

The automated carbon sulfur analyzer couples an induction furnace with a carousel or tray autosampler holding 50–100 pre-weighed crucibles. A pneumatic or robotic arm lifts each crucible into the furnace, closes the chamber, starts combustion, removes the spent crucible, cleans the chamber with a brush and dust extraction, and repeats. Balance integration transfers sample weights automatically to the analysis queue, eliminating transcription errors. A typical cycle takes 60–90 seconds including loading and cleaning, so 50 samples finish in about an hour. The software supports batch sequencing of calibration, drift checks, blanks, and unknowns, with automatic rerun rules if check standards exceed limits. This model suits steel plants running multi-shift production control and independent laboratories that have to document traceable results for every sample.

How does it work?

A carbon sulfur analyzer places a weighed sample of 0.05–1 g in a ceramic crucible, adds tungsten or iron and tin accelerators, and heats it in a high-frequency induction furnace or a resistance tube furnace in flowing oxygen. The accelerators couple with the induction field, melting the sample at 1500–2000 °C and oxidizing carbon to CO2 and sulfur to SO2. Dust is removed by a filter, and the gas passes through infrared absorption cells tuned to about 4.26 µm for CO2 and 7.35 µm for SO2. Absorbance follows the Beer–Lambert relationship, and integrated peak area is converted to mass percent using calibration with certified steel or ore standards. High-carbon and low-carbon channels with different path lengths extend dynamic range from ppm levels to several percent.

What are the key features?

  • Autosampler holds 50–100 pre-weighed crucibles for unattended batch analysis.
  • Automatic furnace brush cleaning and dust extraction after each sample.
  • Balance interface transfers sample weights directly to reduce transcription errors.
  • Batch sequencing includes blanks, calibration checks, and automatic rerun rules.
  • Cycle time of 60–90 seconds including loading and cleaning.
  • Audit trail records operator, standards, and result revisions.

What are the technical specifications?

A typical automated carbon sulfur analyzer with autosampler configuration offers carbon range of 0.0001–6%, sulfur range of 0.0001–0.35%, autosampler capacity of 50–100 crucibles, cycle time of 60–90 s per sample, sample mass of 0.2–1 g and carbon precision (RSD) of ≤0.5% at 0.1% C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Automated Carbon Sulfur Analyzer with Autosampler is used in multi-shift steel plant quality control, foundry melt shop monitoring, third-party testing laboratories and incoming scrap and alloy verification. Across the wider Carbon Sulfur Analyzers class, laboratories also deploy it for steel and cast iron composition control, ferroalloy and metal powder testing and ore, cement, and mineral carbon-sulfur content.

Which standards and certifications apply?

Relevant standards and methods include ASTM E1019, ASTM E1941, ISO 15350, ISO 9556, GB/T 20123, GB/T 223.69 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Crucibles must be pre-ignited at about 1000–1100 °C for one to two hours to reduce carbon blanks, and stored in a desiccator. Oxygen of at least 99.5% purity and a regulated supply of 2–3 bar are standard, with compressed air or nitrogen for pneumatic functions. The dust filter, anhydrone or magnesium perchlorate scrubbers, and furnace chamber need cleaning after a defined number of analyses, typically 30–100 for high-dust steels. Calibrate with certified reference materials bracketing the working range and run drift checks every few hours. Extraction of exhaust gases is required because SO2 is released during combustion. Induction furnaces emit radio-frequency energy and should be installed according to manufacturer guidance and IEC 61010-1 safety requirements.

How do I select the right Automated Carbon Sulfur Analyzer with Autosampler?

Select the automated model when daily volume exceeds about 50 samples or when operator handling introduces variability. For fewer than 20 samples per day, a manual system is usually sufficient. In an RFQ, specify autosampler capacity, balance interface, cleaning method, batch rules, and data system integration with LIMS.

How does it compare with other Carbon Sulfur Analyzers variants?

Choose the furnace type first. High-frequency induction furnaces reach the temperatures needed for refractory metals, alloys, and ferroalloys, and give fast 30–60 second analyses. Resistance tube furnaces suit ores, cement, coal, and minerals, which do not couple with induction, and provide better stability for sulfur in non-metals. Next define the range: ppm-level carbon in ultra-low-carbon steel or titanium requires low-range cells, low blank, and careful crucible handling, while cast iron needs a high-range channel. Consider throughput through autosamplers and automatic cleaning, and check accessory needs such as crucible ovens, balances, and gas purifiers. Confirm that vendor documentation references ASTM E1019 or GB/T 20123, and ask for repeatability on certified reference materials representing your actual grades.

Full specifications

Full specifications
Carbon range0.0001–6%
Sulfur range0.0001–0.35%
Autosampler capacity50–100 crucibles
Cycle time60–90 s per sample
Sample mass0.2–1 g
Carbon precision (RSD)≤0.5% at 0.1% C
FurnaceHigh-frequency induction with auto-cleaning
Balance interfaceRS-232 or USB
DetectorInfrared absorption cells
Power requirement220 V, 50 Hz, about 3 kW

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Multi-shift steel plant quality control
  • Foundry melt shop monitoring
  • Third-party testing laboratories
  • Incoming scrap and alloy verification

Key features

  • Autosampler holds 50–100 pre-weighed crucibles for unattended batch analysis.
  • Automatic furnace brush cleaning and dust extraction after each sample.
  • Balance interface transfers sample weights directly to reduce transcription errors.
  • Batch sequencing includes blanks, calibration checks, and automatic rerun rules.
  • Cycle time of 60–90 seconds including loading and cleaning.
  • Audit trail records operator, standards, and result revisions.

Frequently asked questions about Automated Carbon Sulfur Analyzer with Autosampler

Typical autosamplers hold 50–100 pre-weighed crucibles. With a 60–90 second cycle, a full tray takes about one to two hours. Longer unattended runs are possible if the dust extraction and filter capacity are suitable.

Request a quotation for the Automated Carbon Sulfur Analyzer with Autosampler

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote