96-Well Standard Block Thermal Cycler — product photo

96-Well Standard Block Thermal Cycler

96 孔标准模块热循环仪

  • SKU COP-0001
  • Conventional PCR
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Block format96 × 0.2 mL wells
Temperature range4–99 °C
Max block ramp rate3–4 °C/s
Block uniformity±0.3 °C
Temperature accuracy±0.25 °C
Heated lid range30–110 °C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 20395, ISO 22174, IEC 61010-1

What is the 96-Well Standard Block Thermal Cycler?

A 96-well standard block thermal cycler is the general-purpose PCR instrument, holding one 96-well plate or up to 96 tubes in a single Peltier-controlled block. It is the right choice for routine amplification, cloning and genotyping where moderate speed and reliable uniformity matter more than specialist features.

What is the 96-Well Standard Block Thermal Cycler?

A 96-well standard block thermal cycler is the general-purpose PCR instrument, holding one 96-well plate or up to 96 tubes in a single Peltier-controlled block. It is the right choice for routine amplification, cloning and genotyping where moderate speed and reliable uniformity matter more than specialist features.

Overview

The standard 96-well cycler uses a single aluminum or silver block driven by Peltier elements, with a motorized or manual heated lid that adjusts to tube height. Typical ramp rates are 2–4 °C/s, giving a 30-cycle run in about 1.5–2 hours. Block uniformity is usually within ±0.3 °C and accuracy within ±0.25 °C after stabilization. A color touchscreen stores several hundred programs, and most models support gradient, touchdown and auto-increment steps. Reaction volumes of 5–100 µL are supported. USB or Ethernet ports allow program transfer and, on some models, remote monitoring. The design balances cost, footprint and performance and is widely used as the default laboratory workhorse.

How does it work?

A thermal cycler holds reaction tubes or plates in a metal block whose temperature is controlled by Peltier thermoelectric elements. Each cycle denatures double-stranded DNA at about 94–98 °C, cools to the primer annealing temperature, typically 50–68 °C, and then heats to about 72 °C so a thermostable DNA polymerase extends the primers. Repeating this 25–40 times amplifies the target exponentially. Key components include the Peltier-driven block, a heat sink and fan, a temperature sensor feedback loop, a heated lid that prevents condensation and evaporation, and a controller that stores multi-step programs. Block uniformity and ramp rate determine how reproducibly each well reaches its set temperature.

What are the key features?

  • Single 96-well Peltier block accepts plates, strips and individual tubes
  • Adjustable heated lid prevents condensation without oil overlay
  • Gradient, touchdown and auto-increment programming built in
  • Touchscreen program storage with USB export and import
  • Pause and resume function for manual reagent additions
  • Audible end-of-run and over-temperature alarms

What are the technical specifications?

A typical 96-well standard block thermal cycler configuration offers block format of 96 × 0.2 mL wells, temperature range of 4–99 °C, max block ramp rate of 3–4 °C/s, block uniformity of ±0.3 °C, temperature accuracy of ±0.25 °C and heated lid range of 30–110 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The 96-Well Standard Block Thermal Cycler is used in routine gene amplification, cloning and colony PCR, genotyping and sequencing template preparation. Across the wider Conventional PCR class, laboratories also deploy it for gene cloning and plasmid construction, genotyping and mutation screening and pathogen detection by end-point PCR.

Which standards and certifications apply?

Relevant standards and methods include ISO 20395, ISO 22174, IEC 61010-1, IEC 61010-2-010, MIQE guidelines (research reporting) and CLSI MM19. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the cycler on a stable bench with at least 10 cm of clearance for air intake and exhaust, away from direct sunlight and drafts. Verify block temperature accuracy and uniformity at installation and at least annually using a calibrated multi-point probe, and record results for audit. Clean the block wells with a lint-free swab and 70% ethanol to remove spilled reagent and prevent cross-contamination, and inspect the heated lid seal. Use sealing films or caps matched to the lid pressure. Keep pre-PCR and post-PCR work areas physically separated, and run no-template controls to detect amplicon carry-over. Firmware updates and program backups should be controlled under the laboratory's document system.

How do I select the right 96-Well Standard Block Thermal Cycler?

Select the 96-well standard model for general molecular biology where one program runs at a time and plate compatibility is the main requirement. Compared with dual-block or fast cyclers it costs less, but it cannot run two protocols in parallel. In an RFQ, specify block format, uniformity and accuracy limits, heated lid range, maximum reaction volume, gradient capability, voltage, and whether calibration certificates and installation qualification documents are required.

How does it compare with other Conventional PCR variants?

Choose first by throughput and format: 96-well blocks suit most research work, 384-well blocks suit high-throughput screening, and small 16–48 well units suit teaching or occasional use. Next, compare ramp rate and block uniformity, because fast cyclers shorten run time but need polymerases and buffers validated for short steps. Dual-block instruments allow two independent programs at once and help shared core facilities. Check the heated lid range, programmable features such as touchdown and gradient, and whether the block is interchangeable. Consider connectivity for audit trails if the laboratory works under quality systems, and confirm the tube or plate formats you use, including low-profile plates and strip tubes.

Full specifications

Full specifications
Block format96 × 0.2 mL wells
Temperature range4–99 °C
Max block ramp rate3–4 °C/s
Block uniformity±0.3 °C
Temperature accuracy±0.25 °C
Heated lid range30–110 °C
Reaction volume5–100 µL
Program memory≥ 500 programs
InterfacesUSB, Ethernet
Power supply100–240 V AC, 50/60 Hz, about 600 W

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Routine gene amplification
  • Cloning and colony PCR
  • Genotyping
  • Sequencing template preparation

Key features

  • Single 96-well Peltier block accepts plates, strips and individual tubes
  • Adjustable heated lid prevents condensation without oil overlay
  • Gradient, touchdown and auto-increment programming built in
  • Touchscreen program storage with USB export and import
  • Pause and resume function for manual reagent additions
  • Audible end-of-run and over-temperature alarms

Frequently asked questions about 96-Well Standard Block Thermal Cycler

Only with a dedicated 0.5 mL block. A standard 0.2 mL block does not hold larger tubes. Confirm the block type, or choose an interchangeable-block model, if your protocol needs 0.5 mL tubes for volumes above 100 µL.

Related models

All Conventional PCR

Request a quotation for the 96-Well Standard Block Thermal Cycler

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote