Isoperibol Bomb Calorimeter
等温式氧弹量热仪
- SKU CAL-0002
- Calorimeters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Calorific value range | 5–35 MJ/kg |
|---|---|
| Repeatability | ≤ 0.1 % RSD |
| Test duration | 8–12 min per sample |
| Jacket temperature stability | ± 0.1 °C |
| Temperature resolution | 0.0001 °C |
| Oxygen charging pressure | 30 bar automatic |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D5865, ISO 1928, GB/T 213
What is the Isoperibol Bomb Calorimeter?
An isoperibol bomb calorimeter holds the jacket at a constant temperature while logging the bomb temperature electronically, so no manual reading or correction is needed. It is the standard choice for routine coal testing in commercial laboratories.
What is the Isoperibol Bomb Calorimeter?
An isoperibol bomb calorimeter holds the jacket at a constant temperature while logging the bomb temperature electronically, so no manual reading or correction is needed. It is the standard choice for routine coal testing in commercial laboratories.
Overview
Isoperibol means constant-temperature jacket. The water jacket is held close to a set temperature, usually by a circulation system or a large thermal mass, while the bomb temperature rises after ignition. Because the jacket is not adiabatic, a heat-leak correction is computed from the temperature-time curve by regression, which removes most operator judgement. A microprocessor controls oxygen filling and firing, logs both temperature channels, derives the water equivalent from a benzoic acid run and reports gross and net calorific value on the basis requested. Modern units store hundreds of results, print labels and export to laboratory information systems. Repeatability is typically about 0.1 % relative, and one determination takes eight to twelve minutes, so a laboratory can process twenty or more samples per shift.
How does it work?
A bomb calorimeter burns a pressed pellet of coal, about 0.5 to 1 g, in a high-pressure oxygen bomb immersed in a measured volume of water. The heat released raises the water temperature, and the temperature rise multiplied by the effective heat capacity of the system, called the water equivalent, gives the energy released. Corrections are applied for fuse wire, acid formation and the mass of the crucible contents. In an isoperibol design the jacket stays at a fixed temperature and the temperature-time curve is computed, in an adiabatic design the jacket follows the bomb temperature so heat loss is nearly zero, and in a manual static design the operator reads temperatures and applies a radiation correction. A microprocessor logs the curve, derives the water equivalent from certified benzoic acid and reports the result in MJ/kg.
What are the key features?
- Constant-temperature jacket with electronic two-channel temperature logging
- Automatic oxygen filling, ignition and bomb venting
- Water equivalent computed from certified benzoic acid runs
- Stored methods for coal, coke and solid biofuels
- Direct reporting on as-received, dry and dry ash-free basis
- Export of results to laboratory information systems
What are the technical specifications?
A typical isoperibol bomb calorimeter configuration offers calorific value range of 5–35 MJ/kg, repeatability of ≤ 0.1 % RSD, test duration of 8–12 min per sample, jacket temperature stability of ± 0.1 °C, temperature resolution of 0.0001 °C and oxygen charging pressure of 30 bar automatic. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Isoperibol Bomb Calorimeter is used in routine coal grading and shipment release, coke and solid biofuel calorific value, blending and washing efficiency checks and commercial inspection laboratories. Across the wider Calorimeters class, laboratories also deploy it for coal calorific value for pricing, power plant boiler efficiency monitoring and cement and steel kiln fuel checks.
Which standards and certifications apply?
Relevant standards and methods include ASTM D5865, ISO 1928, GB/T 213, ASTM D3175, ISO 18125, ASTM E711 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the calorimeter on a stable bench away from direct sunlight, draughts and heat sources, because ambient stability affects jacket temperature. Use oxygen of the specified purity from a regulator fitted with a pressure relief, and inspect the bomb, seals and valves on a schedule. Verify the water equivalent at the start of each working session with certified benzoic acid and monitor it as a trend, since drift indicates a leaking bomb, contaminated water or a failing sensor. Keep records of calibration and reference coal results, and compare them with the tolerances stated in the method. Confirm that report basis, sulfur and moisture corrections in the software match your contract.
How do I select the right Isoperibol Bomb Calorimeter?
Choose the isoperibol instrument for regular coal testing where speed and operator-independent results matter. Confirm repeatability against a certified reference coal, the available report bases and autosampler options, and specify the electricity supply, oxygen purity and data interface in the RFQ.
How does it compare with other Calorimeters variants?
Selection turns on required accuracy, sample throughput and how much operator attention your laboratory can accept. Manual static-jacket units are the least expensive and are adequate for occasional checks, but they depend on the operator for temperature reading and correction. Isoperibol instruments dominate routine coal laboratories because they combine good accuracy with automatic temperature logging. Adiabatic calorimeters give the highest precision for reference work and for samples that burn slowly, such as some cokes and biomass, but they cost more and need careful setup. Check water-equivalent stability, reported resolution, the type of oxygen filling system, availability of benzoic acid and certified reference coal, and whether the software reports on the as-received, dry or dry ash-free basis your contract expects.
Full specifications
| Calorific value range | 5–35 MJ/kg |
|---|---|
| Repeatability | ≤ 0.1 % RSD |
| Test duration | 8–12 min per sample |
| Jacket temperature stability | ± 0.1 °C |
| Temperature resolution | 0.0001 °C |
| Oxygen charging pressure | 30 bar automatic |
| Sample mass | 0.5–1.2 g |
| Result storage | ≥ 1000 determinations |
| Data interface | RS232, USB, LAN |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Routine coal grading and shipment release
- Coke and solid biofuel calorific value
- Blending and washing efficiency checks
- Commercial inspection laboratories
Key features
- Constant-temperature jacket with electronic two-channel temperature logging
- Automatic oxygen filling, ignition and bomb venting
- Water equivalent computed from certified benzoic acid runs
- Stored methods for coal, coke and solid biofuels
- Direct reporting on as-received, dry and dry ash-free basis
- Export of results to laboratory information systems
Frequently asked questions about Isoperibol Bomb Calorimeter
It means the surrounding jacket is kept at a constant temperature while the bomb heats up. A heat-leak correction derived from the temperature-time curve compensates for the small difference between the two, giving reproducible results.
Typically at the start of every working session, or at least daily, using certified benzoic acid. Many quality systems also require an annual external verification and a certified reference coal check on a fixed schedule.
Yes, with the correct method and sample preparation it handles coke, solid biofuels, refuse-derived fuel and animal feed. Samples with high moisture or low calorific value may need a combustion aid or a different crucible.
It measures the gross calorific value of a coal sample by burning a weighed pellet in oxygen inside a sealed bomb surrounded by water. The result in MJ/kg is used for pricing, boiler design, blending control and contract compliance.
An isoperibol calorimeter keeps the jacket at a constant temperature and corrects for heat leak, while an adiabatic calorimeter drives the jacket to follow the bomb temperature so heat loss is negligible. Adiabatic units are more precise but slower and more costly.
Verify the water equivalent with certified benzoic acid at the start of each working session, and check the whole method with a certified reference coal at intervals set by your quality system. Annual verification against traceable standards is common practice.