Capillary Zone Electrophoresis System with UV-DAD Detection
配紫外二极管阵列检测器的毛细管区带电泳系统
- CE (to be confirmed)
- +2
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

用于 CE-SDS 蛋白分析的毛细管凝胶电泳系统
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Detection | UV at 220 nm (optional LIF) |
|---|---|
| Separation matrix | Replaceable SDS-gel sieving polymer |
| Capillary internal diameter | 50 µm |
| Effective capillary length | approx. 20–30 cm |
| Separation voltage | approx. −15 kV (reverse polarity) |
| Molecular weight range | approx. 10–250 kDa |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1053>, Ph. Eur. 2.2.47, IEC 61010-1
A CE instrument configured with UV detection at 220 nm, sieving gel and method kits for CE-SDS, measuring size purity and fragments of monoclonal antibodies under reduced and non-reduced conditions. It replaces slab SDS-PAGE in biopharmaceutical QC.
A CE instrument configured with UV detection at 220 nm, sieving gel and method kits for CE-SDS, measuring size purity and fragments of monoclonal antibodies under reduced and non-reduced conditions. It replaces slab SDS-PAGE in biopharmaceutical QC.
CE-SDS applies capillary gel electrophoresis to SDS-denatured proteins, using a replaceable sieving polymer inside a bare fused-silica capillary. Samples are heated with SDS and either a reducing agent or an alkylating agent such as iodoacetamide to give reduced or non-reduced profiles, then injected electrokinetically at negative polarity. Fragments migrate by size and are detected by UV absorbance at 220 nm or by fluorescence when labelled. The system provides quantitative relative percentages of intact IgG, heavy and light chains, and fragments, with precision suitable for lot release, and supports analysis of glycosylation variants such as non-glycosylated heavy chain. Cartridge temperature control, automated capillary rinse, and software with validated reporting, peak integration and audit trail are important in regulated environments. Method kits are typically supplied as a matched set of gel buffer, sample buffer and size standards.
In capillary electrophoresis a fused-silica capillary of 25–100 micrometres internal diameter is filled with a background electrolyte or sieving polymer and connected between two buffer vials with electrodes. A few nanolitres of sample are injected hydrodynamically or electrokinetically and 5–30 kV is applied. The narrow bore dissipates heat efficiently, so high fields can be used, giving fast and sharp separations. Ions migrate according to their charge-to-size ratio, and in capillary zone electrophoresis electroosmotic flow from the charged silica wall carries all species toward the detector. Gel or polymer sieving separates DNA and SDS-protein complexes by size, while isoelectric focusing resolves proteins by pI. Detection is by UV absorbance or diode array, laser-induced fluorescence or mass spectrometry, and data are processed as electropherograms.
A typical capillary gel electrophoresis system for ce-sds protein analysis configuration offers detection of UV at 220 nm (optional LIF), separation matrix of Replaceable SDS-gel sieving polymer, capillary internal diameter of 50 µm, effective capillary length of approx. 20–30 cm, separation voltage of approx. −15 kV (reverse polarity) and molecular weight range of approx. 10–250 kDa. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Capillary Gel Electrophoresis System for CE-SDS Protein Analysis is used in monoclonal antibody purity and lot release, reduced and non-reduced IgG profiles, fragment and aggregate monitoring and stability testing of protein therapeutics. Across the wider Capillary Electrophoresis class, laboratories also deploy it for monoclonal antibody purity and charge variants, STR profiling for forensic identity and DNA fragment sizing and genotyping.
Relevant standards and methods include USP <1053>, Ph. Eur. 2.2.47, IEC 61010-1, IEC 60825-1, 21 CFR Part 11 and ISO 18385. Certification candidates for this model are CE, ISO 9001 manufacturing and 21 CFR Part 11 software compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the instrument on a stable bench with clean power, controlled ambient temperature and, for fluorescence systems, stable laser and optics conditions. Condition new capillaries according to the method, and flush between runs to maintain reproducible electroosmotic flow. Use filtered, degassed buffers and keep vials free of particles, since blockages and bubbles are the most common faults. Replace capillaries, polymer and windows on schedule, and verify performance with size standards or system suitability mixtures. Regulated users should plan IQ/OQ/PQ, calibration and software validation, with audit trails under 21 CFR Part 11. Safety follows IEC 61010-1 with interlocked high-voltage compartments, and laser safety under IEC 60825-1 applies to fluorescence detectors.
Select a dedicated CE-SDS system for antibody size purity testing under regulated conditions. General-purpose UV-CE units can run the method but may lack kits and validation packages. Specify wavelength, sample throughput, temperature control, method kit supply and compliance documentation.
Choose by application first. Capillary zone electrophoresis with UV or diode-array detection covers small ions, peptides, drugs and charge variants. Multi-capillary array analyzers with laser-induced fluorescence suit STR typing, fragment analysis and sequencing. Gel-based CE-SDS is the standard for size purity of monoclonal antibodies, and capillary isoelectric focusing resolves charge heterogeneity. Microchip formats trade resolution for speed and low sample use. Compare capillary count, detection type and sensitivity, temperature control, injection repeatability, autosampler capacity, and the software's audit trail and validation package for regulated use. Also consider consumable cost, such as capillaries, polymer and buffers, and whether the supplier can provide IQ/OQ documentation and method transfer support.
| Detection | UV at 220 nm (optional LIF) |
|---|---|
| Separation matrix | Replaceable SDS-gel sieving polymer |
| Capillary internal diameter | 50 µm |
| Effective capillary length | approx. 20–30 cm |
| Separation voltage | approx. −15 kV (reverse polarity) |
| Molecular weight range | approx. 10–250 kDa |
| Temperature control | approx. 20–40 °C, ±0.1 °C |
| Sample capacity | 96 samples per plate |
| Run time | approx. 25–40 min per sample |
| Purity reproducibility | RSD < 1% for main peak percentage |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
CE-SDS is automated, quantitative and more reproducible than gel staining, with direct UV detection and integrated software. It reports relative purity values with low variability and supports audit trails, which suits lot release and stability programmes.
Reduced CE-SDS breaks disulfide bonds with a reducing agent, giving heavy and light chain peaks. Non-reduced CE-SDS keeps disulfides intact, with iodoacetamide blocking free thiols, and shows intact IgG plus fragments, which reveals covalent fragmentation and aggregation.
Validated CE-SDS methods commonly target a relative standard deviation below 1–2% for the main peak percent area across replicate injections. Acceptance criteria are set during method validation and depend on the product specification.
Capillary electrophoresis separates ions, proteins and nucleic acids in a narrow capillary with on-line detection. It is used for antibody purity and charge variant analysis, STR profiling, DNA fragment sizing, sequencing and the analysis of small ions, drugs and organic acids.
CE separates by charge-to-size ratio in an electric field using tiny sample volumes and no pumped mobile phase, giving high efficiency and low solvent use. HPLC separates by partitioning between mobile and stationary phases and handles larger volumes and neutral analytes more easily.
CE-SDS is capillary gel electrophoresis of SDS-denatured proteins in a sieving polymer. It separates fragments by molecular weight and is widely used to measure size purity of monoclonal antibodies, reduced and non-reduced, as a replacement for slab SDS-PAGE in quality control.

配紫外二极管阵列检测器的毛细管区带电泳系统

配激光诱导荧光的多毛细管阵列遗传分析仪