Capillary Gel Electrophoresis System for CE-SDS Protein Analysis — product photo

Capillary Gel Electrophoresis System for CE-SDS Protein Analysis

用于 CE-SDS 蛋白分析的毛细管凝胶电泳系统

  • SKU CAE-0003
  • Capillary Electrophoresis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • 21 CFR Part 11 software compliance (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
DetectionUV at 220 nm (optional LIF)
Separation matrixReplaceable SDS-gel sieving polymer
Capillary internal diameter50 µm
Effective capillary lengthapprox. 20–30 cm
Separation voltageapprox. −15 kV (reverse polarity)
Molecular weight rangeapprox. 10–250 kDa
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1053>, Ph. Eur. 2.2.47, IEC 61010-1

What is the Capillary Gel Electrophoresis System for CE-SDS Protein Analysis?

A CE instrument configured with UV detection at 220 nm, sieving gel and method kits for CE-SDS, measuring size purity and fragments of monoclonal antibodies under reduced and non-reduced conditions. It replaces slab SDS-PAGE in biopharmaceutical QC.

What is the Capillary Gel Electrophoresis System for CE-SDS Protein Analysis?

A CE instrument configured with UV detection at 220 nm, sieving gel and method kits for CE-SDS, measuring size purity and fragments of monoclonal antibodies under reduced and non-reduced conditions. It replaces slab SDS-PAGE in biopharmaceutical QC.

Overview

CE-SDS applies capillary gel electrophoresis to SDS-denatured proteins, using a replaceable sieving polymer inside a bare fused-silica capillary. Samples are heated with SDS and either a reducing agent or an alkylating agent such as iodoacetamide to give reduced or non-reduced profiles, then injected electrokinetically at negative polarity. Fragments migrate by size and are detected by UV absorbance at 220 nm or by fluorescence when labelled. The system provides quantitative relative percentages of intact IgG, heavy and light chains, and fragments, with precision suitable for lot release, and supports analysis of glycosylation variants such as non-glycosylated heavy chain. Cartridge temperature control, automated capillary rinse, and software with validated reporting, peak integration and audit trail are important in regulated environments. Method kits are typically supplied as a matched set of gel buffer, sample buffer and size standards.

How does it work?

In capillary electrophoresis a fused-silica capillary of 25–100 micrometres internal diameter is filled with a background electrolyte or sieving polymer and connected between two buffer vials with electrodes. A few nanolitres of sample are injected hydrodynamically or electrokinetically and 5–30 kV is applied. The narrow bore dissipates heat efficiently, so high fields can be used, giving fast and sharp separations. Ions migrate according to their charge-to-size ratio, and in capillary zone electrophoresis electroosmotic flow from the charged silica wall carries all species toward the detector. Gel or polymer sieving separates DNA and SDS-protein complexes by size, while isoelectric focusing resolves proteins by pI. Detection is by UV absorbance or diode array, laser-induced fluorescence or mass spectrometry, and data are processed as electropherograms.

What are the key features?

  • Replaceable sieving gel in bare fused-silica capillary gives size-based protein separation
  • UV detection at 220 nm with optional fluorescence supports quantitative purity and impurity reporting
  • Reduced and non-reduced methods report intact IgG, heavy chain, light chain and fragment percentages
  • Thermostated cartridge and automated capillary rinse give reproducible migration between runs
  • Software integrates peaks, reports relative percent area and keeps an audit trail for GMP use
  • Matched method kits supply gel buffer, sample buffer and size standards for consistent results

What are the technical specifications?

A typical capillary gel electrophoresis system for ce-sds protein analysis configuration offers detection of UV at 220 nm (optional LIF), separation matrix of Replaceable SDS-gel sieving polymer, capillary internal diameter of 50 µm, effective capillary length of approx. 20–30 cm, separation voltage of approx. −15 kV (reverse polarity) and molecular weight range of approx. 10–250 kDa. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Capillary Gel Electrophoresis System for CE-SDS Protein Analysis is used in monoclonal antibody purity and lot release, reduced and non-reduced IgG profiles, fragment and aggregate monitoring and stability testing of protein therapeutics. Across the wider Capillary Electrophoresis class, laboratories also deploy it for monoclonal antibody purity and charge variants, STR profiling for forensic identity and DNA fragment sizing and genotyping.

Which standards and certifications apply?

Relevant standards and methods include USP <1053>, Ph. Eur. 2.2.47, IEC 61010-1, IEC 60825-1, 21 CFR Part 11 and ISO 18385. Certification candidates for this model are CE, ISO 9001 manufacturing and 21 CFR Part 11 software compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the instrument on a stable bench with clean power, controlled ambient temperature and, for fluorescence systems, stable laser and optics conditions. Condition new capillaries according to the method, and flush between runs to maintain reproducible electroosmotic flow. Use filtered, degassed buffers and keep vials free of particles, since blockages and bubbles are the most common faults. Replace capillaries, polymer and windows on schedule, and verify performance with size standards or system suitability mixtures. Regulated users should plan IQ/OQ/PQ, calibration and software validation, with audit trails under 21 CFR Part 11. Safety follows IEC 61010-1 with interlocked high-voltage compartments, and laser safety under IEC 60825-1 applies to fluorescence detectors.

How do I select the right Capillary Gel Electrophoresis System for CE-SDS Protein Analysis?

Select a dedicated CE-SDS system for antibody size purity testing under regulated conditions. General-purpose UV-CE units can run the method but may lack kits and validation packages. Specify wavelength, sample throughput, temperature control, method kit supply and compliance documentation.

How does it compare with other Capillary Electrophoresis variants?

Choose by application first. Capillary zone electrophoresis with UV or diode-array detection covers small ions, peptides, drugs and charge variants. Multi-capillary array analyzers with laser-induced fluorescence suit STR typing, fragment analysis and sequencing. Gel-based CE-SDS is the standard for size purity of monoclonal antibodies, and capillary isoelectric focusing resolves charge heterogeneity. Microchip formats trade resolution for speed and low sample use. Compare capillary count, detection type and sensitivity, temperature control, injection repeatability, autosampler capacity, and the software's audit trail and validation package for regulated use. Also consider consumable cost, such as capillaries, polymer and buffers, and whether the supplier can provide IQ/OQ documentation and method transfer support.

Full specifications

Full specifications
DetectionUV at 220 nm (optional LIF)
Separation matrixReplaceable SDS-gel sieving polymer
Capillary internal diameter50 µm
Effective capillary lengthapprox. 20–30 cm
Separation voltageapprox. −15 kV (reverse polarity)
Molecular weight rangeapprox. 10–250 kDa
Temperature controlapprox. 20–40 °C, ±0.1 °C
Sample capacity96 samples per plate
Run timeapprox. 25–40 min per sample
Purity reproducibilityRSD < 1% for main peak percentage

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Monoclonal antibody purity and lot release
  • Reduced and non-reduced IgG profiles
  • Fragment and aggregate monitoring
  • Stability testing of protein therapeutics

Key features

  • Replaceable sieving gel in bare fused-silica capillary gives size-based protein separation
  • UV detection at 220 nm with optional fluorescence supports quantitative purity and impurity reporting
  • Reduced and non-reduced methods report intact IgG, heavy chain, light chain and fragment percentages
  • Thermostated cartridge and automated capillary rinse give reproducible migration between runs
  • Software integrates peaks, reports relative percent area and keeps an audit trail for GMP use
  • Matched method kits supply gel buffer, sample buffer and size standards for consistent results

Frequently asked questions about Capillary Gel Electrophoresis System for CE-SDS Protein Analysis

CE-SDS is automated, quantitative and more reproducible than gel staining, with direct UV detection and integrated software. It reports relative purity values with low variability and supports audit trails, which suits lot release and stability programmes.

Request a quotation for the Capillary Gel Electrophoresis System for CE-SDS Protein Analysis

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote