Skip to main content
Lab Manufacturers China
Vacuum Blotting System for Nucleic Acids — product photo

Vacuum Blotting System for Nucleic Acids

核酸真空转印系统

  • SKU BLS-0004
  • Blotting Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • RoHS (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Transfer area (W x L)approx. 20 x 20 cm (masks for smaller gels)
Vacuum range0–100 mbar (working 40–60 mbar)
Typical transfer time30–90 min
Gels per run1
Membrane compatibilityNylon and nitrocellulose
Fragment size rangeapprox. 0.2–20 kb
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61326-1, ISO 17025

What is the Vacuum Blotting System for Nucleic Acids?

A vacuum-driven blotter that draws transfer buffer through an agarose gel to move DNA or RNA onto a nylon or nitrocellulose membrane in 30–90 minutes. It speeds Southern and northern blotting compared with overnight capillary transfer.

What is the Vacuum Blotting System for Nucleic Acids?

A vacuum-driven blotter that draws transfer buffer through an agarose gel to move DNA or RNA onto a nylon or nitrocellulose membrane in 30–90 minutes. It speeds Southern and northern blotting compared with overnight capillary transfer.

Overview

A vacuum blotter consists of a porous support plate in a vacuum chamber, a gasket or mask that seals the membrane area, and a vacuum pump or controller. The membrane sits on the plate, the gel on the membrane, and buffer is applied above the gel so that vacuum of about 40–60 mbar pulls denaturing or neutralising solutions through the gel onto the membrane. Depurination, denaturation and transfer steps can be performed sequentially without moving the gel, and transfer is typically complete in 30–90 minutes. The vacuum is gentle enough to preserve gel integrity, and the mask ensures that transfer occurs only through the gel area. Vacuum blotting is faster than capillary transfer and gives even results, particularly for large fragments. It needs a regulated vacuum pump and careful seal control, and is used mainly for Southern and northern blots.

How does it work?

Blotting moves separated molecules from a fragile gel to a durable membrane while preserving their relative positions. In electroblotting, the gel and membrane are pressed together in a sandwich between filter papers and sponges or buffer-wetted stacks, and an electric field drives charged molecules out of the gel and onto the membrane, where they bind by hydrophobic or electrostatic interaction. Wet tank systems submerge the sandwich in buffer between plate electrodes, semi-dry systems place it between flat graphite or metal plate electrodes with only buffer-soaked paper, and rapid systems use high current with special buffers. Vacuum and capillary blotting draw buffer through the gel to carry nucleic acids onto the membrane. After transfer, the membrane is blocked and probed, and signals are detected chemically or by fluorescence.

What are the key features?

  • Regulated vacuum of about 40–60 mbar pulls buffer through the gel without damaging it
  • Transfer completes in 30–90 minutes, far shorter than overnight capillary blotting
  • Depurination, denaturation and neutralisation steps run in place without moving the gel
  • Interchangeable masks limit transfer to the gel area and seal the membrane edges
  • Porous support plate provides even vacuum distribution across the whole membrane
  • Vacuum gauge and regulator give reproducible transfer conditions between runs

What are the technical specifications?

A typical vacuum blotting system for nucleic acids configuration offers transfer area (W x L) of approx. 20 x 20 cm (masks for smaller gels), vacuum range of 0–100 mbar (working 40–60 mbar), typical transfer time of 30–90 min, gels per run of 1, membrane compatibility of Nylon and nitrocellulose and fragment size range of approx. 0.2–20 kb. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Vacuum Blotting System for Nucleic Acids is used in southern blotting, northern blotting, genomic DNA restriction analysis and gene copy number studies. Across the wider Blotting Systems class, laboratories also deploy it for western blotting, southern blotting and northern blotting.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61326-1, ISO 17025, Ph. Eur. 2.2.31 and USP <1053>. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Good contact between gel and membrane without trapped bubbles is the main factor for transfer quality, so roll out air with a tube before closing the cassette. Pre-wet PVDF in methanol and equilibrate gels in transfer buffer. Keep buffer cold or use an ice pack and stirrer for wet transfers to limit heating. Do not exceed the current or voltage limits of the tank, and follow the orientation of electrodes carefully. Clean electrodes and cassettes regularly, and do not leave buffer in the tank. Mind methanol flammability and the chemical safety of acrylamide and probe reagents. Electrical safety follows IEC 61010-1, and transfer efficiency should be checked with reversible stains or pre-stained markers.

How do I select the right Vacuum Blotting System for Nucleic Acids?

Select vacuum blotting for regular Southern or northern work where overnight capillary transfer is a bottleneck. It needs a regulated pump and accurate sealing. Specify gel size, vacuum range, mask options, membrane types and whether the vacuum source is supplied.

How does it compare with other Blotting Systems variants?

Choose the transfer format from the target and the workload. Wet tank transfer is the most forgiving for large proteins above 100 kDa and for quantitative work. Semi-dry is faster and uses less buffer, which suits routine transfers of small and medium proteins. Rapid systems finish in about 7–10 minutes and suit high sample turnover but need matching consumables. Vacuum and capillary blotting are standard for Southern and northern work with large DNA and RNA fragments. Dot or slot manifolds are used when no separation is needed. Check transfer area against your gel format, membrane compatibility with PVDF, nitrocellulose or nylon, cooling options, maximum current and whether the power supply you have can drive the system.

Full specifications

Full specifications
Transfer area (W x L)approx. 20 x 20 cm (masks for smaller gels)
Vacuum range0–100 mbar (working 40–60 mbar)
Typical transfer time30–90 min
Gels per run1
Membrane compatibilityNylon and nitrocellulose
Fragment size rangeapprox. 0.2–20 kb
Support materialPorous polyethylene or sintered plate
Vacuum sourceDiaphragm pump with regulator
Gasket materialSilicone
Housing materialAcrylic

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Southern blotting
  • Northern blotting
  • Genomic DNA restriction analysis
  • Gene copy number studies

Key features

  • Regulated vacuum of about 40–60 mbar pulls buffer through the gel without damaging it
  • Transfer completes in 30–90 minutes, far shorter than overnight capillary blotting
  • Depurination, denaturation and neutralisation steps run in place without moving the gel
  • Interchangeable masks limit transfer to the gel area and seal the membrane edges
  • Porous support plate provides even vacuum distribution across the whole membrane
  • Vacuum gauge and regulator give reproducible transfer conditions between runs

Frequently asked questions about Vacuum Blotting System for Nucleic Acids

Vacuum actively pulls buffer through the gel at a controlled rate, whereas capillary transfer relies on slow wicking by paper towels. This shortens transfer from overnight to roughly 30–90 minutes with even results across the gel.

Related models

All Blotting Systems

Request a quotation for the Vacuum Blotting System for Nucleic Acids

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote