Key specifications
| Output voltage | up to 3000 V DC |
|---|---|
| Output current | up to 400 mA |
| Maximum power | 100–200 W |
| Operating modes | Constant power (voltage and current limiting) |
| Programmable steps | up to 5 (pre-run, ramp, run) |
| Number of outputs | 1 |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61326-1, IEC 61010-2-010
What is the High-Power Power Supply for Sequencing and Denaturing Gels?
A high-voltage, constant-power supply reaching 3000 V and 100–200 W with thermal plate control, built for sequencing slab gels and denaturing PAGE. It stabilises gel temperature and migration speed during long high-voltage runs.
What is the High-Power Power Supply for Sequencing and Denaturing Gels?
A high-voltage, constant-power supply reaching 3000 V and 100–200 W with thermal plate control, built for sequencing slab gels and denaturing PAGE. It stabilises gel temperature and migration speed during long high-voltage runs.
Overview
Sequencing and other denaturing gels are run at 1500–3000 V and 50–100 W, and the heat generated must be regulated to keep the gel near 50 °C. A constant-power supply keeps heating steady as resistance changes, which gives predictable migration and sharp bands. The high-power unit offers up to 3000 V, 200–400 mA and 100–200 W, with voltage and current limiting as secondary controls. Precise timers, a power ramp to reduce thermal shock and step programs for pre-run and run stages are standard. The floating output with ground-leak detection and interlocks is essential at this voltage. Connectors are high-voltage rated and shrouded. Some models include a thermostat input so that a thermostatic plate on the apparatus can be switched or monitored.
How does it work?
An electrophoresis power supply converts mains alternating current into a regulated direct-current output. A transformer or switch-mode stage steps the voltage, a rectifier and filter create DC, and a feedback loop holds one chosen variable constant. Because the electrical resistance of a gel changes during a run as ions migrate and buffer heats, the three quantities voltage, current and power are linked by Ohm's law and P = V x I. Constant voltage gives predictable field strength, constant current keeps migration speed steady, and constant power limits heating. Most supplies switch automatically to a limiting mode when a set limit is reached. Key features include multiple outputs, programmable multi-step runs, timers, amp-hour accumulation, no-load and short-circuit detection, and isolated outputs with safety interlocks.
What are the key features?
- Constant-power operation up to 100–200 W holds gel temperature steady during long runs
- Output to 3000 V with floating isolation and ground-leak detection for operator safety
- Power ramp and pre-run step programs reduce thermal shock to thin gels
- High-voltage shrouded connectors and lid interlock are required for 3000 V operation
- Optional thermostat input links the supply with a thermostatic plate on the apparatus
- Digital display shows voltage, current, power, elapsed time and set point for each step
What are the technical specifications?
A typical high-power power supply for sequencing and denaturing gels configuration offers output voltage of up to 3000 V DC, output current of up to 400 mA, maximum power of 100–200 W, operating modes of Constant power (voltage and current limiting), programmable steps of up to 5 (pre-run, ramp, run) and number of outputs of 1. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The High-Power Power Supply for Sequencing and Denaturing Gels is used in DNA sequencing slab gels, denaturing PAGE for oligonucleotides, primer extension and footprinting and AFLP and microsatellite gels. Across the wider Power Supplies class, laboratories also deploy it for agarose gel electrophoresis, SDS-PAGE and native PAGE and western blot transfer.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61326-1, IEC 61010-2-010, ISO 17025 and 21 CFR Part 11. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the supply on a dry bench away from splash and buffer spills, and never operate it with damaged leads. Connect cables with the supply switched off and respect polarity colours. Use only tanks with interlocked lids and shrouded connectors rated for the output voltage. Verify output accuracy periodically against a calibrated meter, and keep vents clear for cooling. Output above 60 V DC is hazardous, so staff should be trained and local electrical safety rules followed. Safety compliance is typically based on IEC 61010-1 and EMC on IEC 61326-1. For regulated laboratories, schedule calibration, keep service records and store run parameters where data integrity is required.
How do I select the right High-Power Power Supply for Sequencing and Denaturing Gels?
Select a high-power constant-power supply for sequencing and denaturing slab gels, which general 300 V supplies cannot drive. Specify maximum voltage and power, constant-power accuracy, step programming, thermostat interface and safety interlock connector type for your apparatus.
How does it compare with other Power Supplies variants?
Match the power supply to the most demanding application. Gel electrophoresis of DNA usually needs up to 300 V and 400 mA, protein and blotting work need higher current, and isoelectric focusing or sequencing need 2000–5000 V at low current. Decide whether constant voltage alone is sufficient or constant current and power modes are also needed. Programmable multi-step protocols, such as ramped focusing, require memory and stepping. Count how many tanks run together, because multiple outputs share total power. Look for clear displays, automatic overload, no-load and short-circuit protection, isolation from earth, and compliance with IEC 61010-1. Check connector type and whether cables are compatible with your tanks, and consider remote-control or USB options for documentation.
Full specifications
| Output voltage | up to 3000 V DC |
|---|---|
| Output current | up to 400 mA |
| Maximum power | 100–200 W |
| Operating modes | Constant power (voltage and current limiting) |
| Programmable steps | up to 5 (pre-run, ramp, run) |
| Number of outputs | 1 |
| Timer | Up to 99 h 59 min |
| Voltage accuracy | ±2% |
| Isolation | Floating output with ground-leak detection |
| Power input | 100–240 V AC, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- DNA sequencing slab gels
- Denaturing PAGE for oligonucleotides
- Primer extension and footprinting
- AFLP and microsatellite gels
Key features
- Constant-power operation up to 100–200 W holds gel temperature steady during long runs
- Output to 3000 V with floating isolation and ground-leak detection for operator safety
- Power ramp and pre-run step programs reduce thermal shock to thin gels
- High-voltage shrouded connectors and lid interlock are required for 3000 V operation
- Optional thermostat input links the supply with a thermostatic plate on the apparatus
- Digital display shows voltage, current, power, elapsed time and set point for each step
Frequently asked questions about High-Power Power Supply for Sequencing and Denaturing Gels
Gel heating is proportional to power, so constant power keeps temperature steady even as resistance changes during the run. This gives reproducible migration and helps maintain the roughly 50 °C needed to keep DNA fully denatured.
Look for floating output with ground-leak detection, lid interlock, shrouded high-voltage connectors, automatic shutdown on faults, and compliance with IEC 61010-1. Operators should be trained, and leads inspected before each run.
A pre-run applies power to an empty, loaded-buffer gel for 30–60 minutes before sample loading. It warms the gel to working temperature and removes ions and impurities, which helps produce sharper bands in the actual run.
It is a regulated direct-current source that drives gel tanks, blotting units and focusing cells. It holds voltage, current or power constant while the gel resistance changes, which gives reproducible migration, and includes protections such as overload, no-load and short-circuit detection.
Constant voltage is standard for agarose gels because field strength stays fixed. Constant current is often used for SDS-PAGE and blotting, keeping migration speed steady as resistance rises, while constant power limits heating in sequencing gels and focusing.
DNA agarose gels need up to 300 V and 400 mA, protein gels about 300–500 V, blotting 100 V at up to 2.5 A, and isoelectric focusing 3500 V or more at low current. Choose a supply rated above your peak demand.
Related models