Whiteness Tester for Paper
纸张 D65 白度仪
- SKU BRT-0002
- Brightness Testing
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Whiteness indices | CIE whiteness per ISO 11475 or 11476 |
|---|---|
| Illuminants | D65 and C with defined UV content |
| Observer | 2° or 10° standard observer |
| Spectral range | 400–700 nm at 10 nm intervals |
| Repeatability | ±0.1 whiteness unit |
| Measuring area | 10–30 mm diameter |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 2470-1, ISO 2470-2, ISO 2471
What is the Whiteness Tester for Paper?
A whiteness tester derives the CIE whiteness index and tint from the colour coordinates of a paper specimen under illuminant D65 or C. It quantifies how white a sheet appears, including the effect of fluorescent whitening agents.
What is the Whiteness Tester for Paper?
A whiteness tester derives the CIE whiteness index and tint from the colour coordinates of a paper specimen under illuminant D65 or C. It quantifies how white a sheet appears, including the effect of fluorescent whitening agents.
Overview
Whiteness is not a direct reflectance measurement but a formula applied to the tristimulus values of the specimen, which requires measurements at several wavelengths across the visible range. A tristimulus colorimeter or spectrophotometer therefore forms the basis of the instrument, with a tungsten or xenon source whose ultraviolet content is controlled, because whiteness values of papers containing fluorescent whiteners depend on the ultraviolet in the illumination. Results are reported as whiteness index, tint and often yellowness, using the illuminant and observer combination named in the standard. Because the calculation uses the whole visible spectrum, the instrument distinguishes papers that have the same ISO brightness but different hue, which is important for shade matching in coated and writing grades.
How does it work?
A brightness or reflectance instrument illuminates the specimen diffusely and measures the light reflected at right angles, using a defined geometry, illuminant and observer so that results are reproducible between laboratories. ISO brightness is the diffuse blue reflectance factor measured with an effective wavelength of 457 nm under illuminant C, and it is highly sensitive to fluorescent whitening agents. Whiteness is a single number derived from the full colour coordinates under illuminant D65 or C, while yellowness, tint and shade are obtained from the same measurement. Opacity is the ratio of reflectance of a stack-backed specimen to that of an infinite stack, and can be determined by diffuse reflectance or by the contrast ratio of luminous reflectance. Gloss is measured separately at a fixed angle of incidence, because it depends on surface finish rather than on bulk optical properties.
What are the key features?
- CIE whiteness index calculation from tristimulus values
- Illuminants D65 and C with controlled UV content
- Tint, yellowness and shade reporting
- White standard calibration per measurement series
- Optional UV cut-off filter for fluorescence control
- Comparison against grade-specific targets
What are the technical specifications?
A typical whiteness tester for paper configuration offers whiteness indices of CIE whiteness per ISO 11475 or 11476, illuminants of D65 and C with defined UV content, observer of 2° or 10° standard observer, spectral range of 400–700 nm at 10 nm intervals, repeatability of ±0.1 whiteness unit and measuring area of 10–30 mm diameter. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Whiteness Tester for Paper is used in whiteness specification testing of coated papers, shade control in writing and office papers, fluorescent whitening agent performance checks and incoming inspection of pulp whiteness. Across the wider Brightness Testing class, laboratories also deploy it for brightness verification of printing and writing papers, whiteness and shade control for coated papers and opacity checks for lightweight printing grades.
Which standards and certifications apply?
Relevant standards and methods include ISO 2470-1, ISO 2470-2, ISO 2471, ISO 11475, ISO 11476, ISO 5631-1, TAPPI T452, TAPPI T525 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Keep the instrument calibrated with certified standards traceable to a national laboratory, and check the white standard and black trap at the start of each measurement series. Stack at least the number of sheets the method requires behind the specimen to ensure an opaque backing, because too few sheets allow the backing plate to influence the reading. Condition specimens to the standard atmosphere and protect them from light and heat, since fluorescent whitening agents bleach and papers yellow on exposure. Clean the measuring aperture and the standard regularly, avoid touching the measurement area of the specimen with fingers, and record the geometry, illuminant and observer with every result.
How do I select the right Whiteness Tester for Paper?
Choose a whiteness tester when the specification is expressed as a CIE whiteness index or when shade and tint must be controlled alongside brightness. Confirm that the standard you follow specifies the illuminant and observer combination, and check whether a UV filter or adjustable ultraviolet content is required for fluorescence control.
How does it compare with other Brightness Testing variants?
Match the instrument to the parameter named in the product standard. ISO brightness requires a 457 nm effective wavelength with the specified geometry, while D65 whiteness, colour and yellowness require a spectrophotometer covering the visible range under standard illuminants and observers. Opacity is measured with either a dedicated contrast ratio instrument or a spectrophotometer able to compute it from reflectance data. Gloss needs a dedicated meter with the correct incidence angle for the paper grade. Where the laboratory also verifies print appearance or matches shades, a benchtop spectrophotometer with both measurement geometries and a full set of illuminant and observer combinations is more useful than a single purpose meter, even though it costs more.
Full specifications
| Whiteness indices | CIE whiteness per ISO 11475 or 11476 |
|---|---|
| Illuminants | D65 and C with defined UV content |
| Observer | 2° or 10° standard observer |
| Spectral range | 400–700 nm at 10 nm intervals |
| Repeatability | ±0.1 whiteness unit |
| Measuring area | 10–30 mm diameter |
| Sheets in pad | Per the method |
| Data output | Whiteness, tint, yellowness, spectral data |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Whiteness specification testing of coated papers
- Shade control in writing and office papers
- Fluorescent whitening agent performance checks
- Incoming inspection of pulp whiteness
Key features
- CIE whiteness index calculation from tristimulus values
- Illuminants D65 and C with controlled UV content
- Tint, yellowness and shade reporting
- White standard calibration per measurement series
- Optional UV cut-off filter for fluorescence control
- Comparison against grade-specific targets
Frequently asked questions about Whiteness Tester for Paper
Brightness is a single reflectance value in the blue region, while whiteness is computed from the whole visible spectrum and includes a tint component. Papers with different absorbing and fluorescent additive combinations can therefore match in brightness while appearing slightly different in shade, which the whiteness index reveals.
It depends on the standard being applied: ISO 11475 uses D65, while ISO 11476 uses illuminant C with the 2 degree observer. D65 corresponds more closely to daylight and is the more common choice for appearance-related specifications, but the standard named in the product specification takes precedence.
By measuring the same certified white standard and, where possible, a set of coloured reference tiles at the start and end of each session and comparing the values with their certificates. A drift in the white standard reading indicates an instrument problem, while a drift in the tiles alone often points to a filter or wavelength scale issue.
It measures the diffuse blue reflectance factor of a pad of sheets at an effective wavelength of 457 nm under illuminant C. Because the measurement is in the blue region, it is very sensitive both to the bleaching state of the pulp and to fluorescent whitening agents, which raise the value by converting ultraviolet light into visible blue.
A single sheet is partly translucent, so light reflected from the backing plate would add to the reading. Stacking a defined number of sheets makes the pad optically opaque, so the value depends only on the specimen, and the same number of sheets must be used as in the method to keep results comparable.
Yes. Reflectance scales are instrument dependent, so a certified white standard traceable to a national metrology institute and a black trap are used to set the scale before measurement. The standard's calibration date must be current, and the black trap must be clean to avoid an offset at the low end of the scale.