High-Throughput Automated Coagulation Analyzer
高通量全自动凝血分析仪
- SKU ACA-0003
- Automatic Coagulation Analyzers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA class II registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Throughput | 400–800 clotting tests/h |
|---|---|
| Sample positions | 80–150 with continuous loading |
| Reagent positions | 40–60 across two or more carousels |
| Detection principles | Optical scatter with mechanical or chromogenic options |
| First-result time | PT about 1–2 min; D-dimer 15–25 min |
| STAT handling | Dedicated priority positions and channels |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI H57, CLSI H21
What is the High-Throughput Automated Coagulation Analyzer?
This analyzer processes 400 to 800 clotting tests per hour with multiple reagent carousels and parallel reaction channels. It suits large hospital core laboratories and reference laboratories where hemostasis volume is consolidated on one platform.
What is the High-Throughput Automated Coagulation Analyzer?
This analyzer processes 400 to 800 clotting tests per hour with multiple reagent carousels and parallel reaction channels. It suits large hospital core laboratories and reference laboratories where hemostasis volume is consolidated on one platform.
Overview
Parallel reaction channels, a large sample loader and two or more refrigerated reagent carousels allow the analyzer to run continuously without refilling or waiting. Bulk reagent positions and level monitoring reduce intervention, and the software balances workloads across channels so that turnaround stays stable at high load. Detection may combine optical and mechanical principles so that lipemic or icteric samples can be measured on the appropriate channel. Reflex rules, delta checks and automatic reruns are applied without operator action, and the system supports secondary tubes for children and external quality assessment samples. Because a single platform carries most of the laboratory's hemostasis workload, redundancy planning, a service contract with a defined response time and a stock of critical reagents and cuvettes are essential.
How does it work?
An automatic analyzer moves plasma from a sample tube to a reaction cuvette, adds reagent from a cooled position, incubates at 37 degrees Celsius and starts the measurement. Detection may be optical, using the change in light scatter or turbidity as fibrin forms; mechanical or magnetic, following the movement of a ball; or chromogenic, measuring the colour released from a synthetic substrate at 405 nanometers. Immunoturbidimetric channels measure light scattered by antigen-antibody complexes for assays such as D-dimer. The software applies the stored calibration for each reagent lot, calculates ratios and international normalised ratios, applies reflex rules such as automatic repeat at a dilution, and flags results for review. Random access allows any test combination on any sample, and STAT samples are given priority so that emergency results are not delayed by routine batches.
What are the key features?
- Parallel reaction channels with 400 to 800 tests per hour
- Two or more refrigerated reagent carousels with level monitoring
- Combined optical and mechanical detection options
- Automatic workload balancing across channels
- Reflex rules and delta checks applied without intervention
- Support for secondary tubes and quality assessment samples
What are the technical specifications?
A typical high-throughput automated coagulation analyzer configuration offers throughput of 400–800 clotting tests/h, sample positions of 80–150 with continuous loading, reagent positions of 40–60 across two or more carousels, detection principles of Optical scatter with mechanical or chromogenic options, first-result time of PT about 1–2 min; D-dimer 15–25 min and STAT handling of Dedicated priority positions and channels. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The High-Throughput Automated Coagulation Analyzer is used in large hospital hemostasis core laboratory, reference laboratory high-volume coagulation, consolidated anticoagulation monitoring services and clinical trial central laboratory testing. Across the wider Automatic Coagulation Analyzers class, laboratories also deploy it for hospital routine and emergency hemostasis testing, anticoagulation monitoring and dosing and pre-operative and bleeding disorder assessment.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI H57, CLSI H21, CLSI EP05, CLSI EP15, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the analyzer on a stable bench or floor position with controlled temperature, a grounded power supply and space for reagent and waste containers, and verify performance at installation with precision, linearity and method comparison studies for every assay reported. Daily work includes running normal and abnormal control plasma, checking reagent and cuvette status and reviewing calibration validity. Optical and mechanical detection systems need periodic cleaning and mechanical alignment checks, and the sample and reagent probes require regular decontamination. Because pre-analytical variables strongly influence coagulation results, the laboratory should monitor tube fill, transport time and centrifugation parameters as part of quality management, and participate in external quality assessment for all reported assays.
How do I select the right High-Throughput Automated Coagulation Analyzer?
Specify a high-throughput platform when daily hemostasis volume exceeds about four hundred tests, when several analyzers currently run in parallel, or when the laboratory reports large D-dimer batches. In the RFQ confirm throughput on your assay mix, reagent carousel capacity, STAT behaviour under full load, and the response time committed in the service agreement.
How does it compare with other Automatic Coagulation Analyzers variants?
Match the instrument to your workload and menu. A benchtop analyzer with two to six reagent positions suits a laboratory reporting one hundred to three hundred tests per day, while high-throughput models with multiple reagent carousels are needed above about five hundred tests. Check which detection principles are available, because chromogenic and immunoturbidimetric assays require additional channels and reagents, and check whether cap piercing is needed for biosafety. Consider the sample volume for pediatric tubes, reagent onboard capacity and refrigeration, STAT handling and first-result time, reflex rules such as automatic dilution, and the availability of application support and calibrators. Confirm LIS connectivity and the traceability features, including lot, curve and operator records required for accreditation.
Full specifications
| Throughput | 400–800 clotting tests/h |
|---|---|
| Sample positions | 80–150 with continuous loading |
| Reagent positions | 40–60 across two or more carousels |
| Detection principles | Optical scatter with mechanical or chromogenic options |
| First-result time | PT about 1–2 min; D-dimer 15–25 min |
| STAT handling | Dedicated priority positions and channels |
| Water and waste | Purified water optional; waste container required |
| Footprint | 2.0–3.0 m² including service access |
| Interfaces | LAN with HL7 or ASTM and optional track connection |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Large hospital hemostasis core laboratory
- Reference laboratory high-volume coagulation
- Consolidated anticoagulation monitoring services
- Clinical trial central laboratory testing
Key features
- Parallel reaction channels with 400 to 800 tests per hour
- Two or more refrigerated reagent carousels with level monitoring
- Combined optical and mechanical detection options
- Automatic workload balancing across channels
- Reflex rules and delta checks applied without intervention
- Support for secondary tubes and quality assessment samples
Frequently asked questions about High-Throughput Automated Coagulation Analyzer
Immunoturbidimetric assays such as D-dimer occupy reaction channels for ten to twenty minutes, so a run dominated by these tests delivers far fewer results per hour than the headline clotting time figure. Ask for throughput measured on a mix similar to your own.
A backup plan is essential because one platform carries the whole workload. Options include a benchtop analyzer for urgent tests, a service contract with spare parts on site and a written procedure for referring samples during downtime, all kept current through periodic drills.
They are best scheduled in batches on dedicated channels so that routine clotting tests retain their short turnaround. The software should support workload balancing and priority rules, and the laboratory should monitor queue length and expired reagent positions during high-load periods.
Most high-throughput coagulation analyzers need a nearby waste container but no special ventilation, because reagents are aqueous and volumes are small. Confirm the electrical supply, network connection and floor loading during site planning, since the platform occupies two to three square meters with service access.
An automatic analyzer aspirates samples and reagents, incubates, detects the endpoint and reports results without manual pipetting, and it can run samples in any order. A semi-automatic instrument requires the operator to add sample and reagent but performs incubation and detection itself.
Optical detection is the most common and supports both clot-based and chromogenic assays but is affected by icterus, hemolysis and lipemia. Mechanical detection is largely free of these interferences, and many platforms combine both principles to offer flexibility for different sample types.
Clotting time tests such as PT and APTT usually report within one to five minutes of reagent addition, with total turnaround from sample receipt of fifteen to thirty minutes. Immunoturbidimetric assays such as D-dimer take longer, often fifteen to forty minutes depending on the platform.
Related models



Automated Coagulation Analyzer with Immunoturbidimetric Assays
带免疫比浊项目的全自动凝血分析仪
- CE (to be confirmed)
- +2

Fully Automated Coagulation Analyzer with Cap-Piercing Autoloader
带穿刺开盖进样器的全自动凝血分析仪
- CE (to be confirmed)
- +2


Semi-Automatic Coagulation Analyzer with Chromogenic Capability
具显色法功能的半自动凝血分析仪
- CE (to be confirmed)
- +2