High-Throughput Automated Coagulation Analyzer

高通量全自动凝血分析仪

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Throughput400–800 clotting tests/h
Sample positions80–150 with continuous loading
Reagent positions40–60 across two or more carousels
Detection principlesOptical scatter with mechanical or chromogenic options
First-result timePT about 1–2 min; D-dimer 15–25 min
STAT handlingDedicated priority positions and channels
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI H57, CLSI H21

What is the High-Throughput Automated Coagulation Analyzer?

This analyzer processes 400 to 800 clotting tests per hour with multiple reagent carousels and parallel reaction channels. It suits large hospital core laboratories and reference laboratories where hemostasis volume is consolidated on one platform.

What is the High-Throughput Automated Coagulation Analyzer?

This analyzer processes 400 to 800 clotting tests per hour with multiple reagent carousels and parallel reaction channels. It suits large hospital core laboratories and reference laboratories where hemostasis volume is consolidated on one platform.

Overview

Parallel reaction channels, a large sample loader and two or more refrigerated reagent carousels allow the analyzer to run continuously without refilling or waiting. Bulk reagent positions and level monitoring reduce intervention, and the software balances workloads across channels so that turnaround stays stable at high load. Detection may combine optical and mechanical principles so that lipemic or icteric samples can be measured on the appropriate channel. Reflex rules, delta checks and automatic reruns are applied without operator action, and the system supports secondary tubes for children and external quality assessment samples. Because a single platform carries most of the laboratory's hemostasis workload, redundancy planning, a service contract with a defined response time and a stock of critical reagents and cuvettes are essential.

How does it work?

An automatic analyzer moves plasma from a sample tube to a reaction cuvette, adds reagent from a cooled position, incubates at 37 degrees Celsius and starts the measurement. Detection may be optical, using the change in light scatter or turbidity as fibrin forms; mechanical or magnetic, following the movement of a ball; or chromogenic, measuring the colour released from a synthetic substrate at 405 nanometers. Immunoturbidimetric channels measure light scattered by antigen-antibody complexes for assays such as D-dimer. The software applies the stored calibration for each reagent lot, calculates ratios and international normalised ratios, applies reflex rules such as automatic repeat at a dilution, and flags results for review. Random access allows any test combination on any sample, and STAT samples are given priority so that emergency results are not delayed by routine batches.

What are the key features?

  • Parallel reaction channels with 400 to 800 tests per hour
  • Two or more refrigerated reagent carousels with level monitoring
  • Combined optical and mechanical detection options
  • Automatic workload balancing across channels
  • Reflex rules and delta checks applied without intervention
  • Support for secondary tubes and quality assessment samples

What are the technical specifications?

A typical high-throughput automated coagulation analyzer configuration offers throughput of 400–800 clotting tests/h, sample positions of 80–150 with continuous loading, reagent positions of 40–60 across two or more carousels, detection principles of Optical scatter with mechanical or chromogenic options, first-result time of PT about 1–2 min; D-dimer 15–25 min and STAT handling of Dedicated priority positions and channels. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The High-Throughput Automated Coagulation Analyzer is used in large hospital hemostasis core laboratory, reference laboratory high-volume coagulation, consolidated anticoagulation monitoring services and clinical trial central laboratory testing. Across the wider Automatic Coagulation Analyzers class, laboratories also deploy it for hospital routine and emergency hemostasis testing, anticoagulation monitoring and dosing and pre-operative and bleeding disorder assessment.

Which standards and certifications apply?

Relevant standards and methods include ISO 15189, CLSI H57, CLSI H21, CLSI EP05, CLSI EP15, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the analyzer on a stable bench or floor position with controlled temperature, a grounded power supply and space for reagent and waste containers, and verify performance at installation with precision, linearity and method comparison studies for every assay reported. Daily work includes running normal and abnormal control plasma, checking reagent and cuvette status and reviewing calibration validity. Optical and mechanical detection systems need periodic cleaning and mechanical alignment checks, and the sample and reagent probes require regular decontamination. Because pre-analytical variables strongly influence coagulation results, the laboratory should monitor tube fill, transport time and centrifugation parameters as part of quality management, and participate in external quality assessment for all reported assays.

How do I select the right High-Throughput Automated Coagulation Analyzer?

Specify a high-throughput platform when daily hemostasis volume exceeds about four hundred tests, when several analyzers currently run in parallel, or when the laboratory reports large D-dimer batches. In the RFQ confirm throughput on your assay mix, reagent carousel capacity, STAT behaviour under full load, and the response time committed in the service agreement.

How does it compare with other Automatic Coagulation Analyzers variants?

Match the instrument to your workload and menu. A benchtop analyzer with two to six reagent positions suits a laboratory reporting one hundred to three hundred tests per day, while high-throughput models with multiple reagent carousels are needed above about five hundred tests. Check which detection principles are available, because chromogenic and immunoturbidimetric assays require additional channels and reagents, and check whether cap piercing is needed for biosafety. Consider the sample volume for pediatric tubes, reagent onboard capacity and refrigeration, STAT handling and first-result time, reflex rules such as automatic dilution, and the availability of application support and calibrators. Confirm LIS connectivity and the traceability features, including lot, curve and operator records required for accreditation.

Full specifications

Full specifications
Throughput400–800 clotting tests/h
Sample positions80–150 with continuous loading
Reagent positions40–60 across two or more carousels
Detection principlesOptical scatter with mechanical or chromogenic options
First-result timePT about 1–2 min; D-dimer 15–25 min
STAT handlingDedicated priority positions and channels
Water and wastePurified water optional; waste container required
Footprint2.0–3.0 m² including service access
InterfacesLAN with HL7 or ASTM and optional track connection

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Large hospital hemostasis core laboratory
  • Reference laboratory high-volume coagulation
  • Consolidated anticoagulation monitoring services
  • Clinical trial central laboratory testing

Key features

  • Parallel reaction channels with 400 to 800 tests per hour
  • Two or more refrigerated reagent carousels with level monitoring
  • Combined optical and mechanical detection options
  • Automatic workload balancing across channels
  • Reflex rules and delta checks applied without intervention
  • Support for secondary tubes and quality assessment samples

Frequently asked questions about High-Throughput Automated Coagulation Analyzer

Immunoturbidimetric assays such as D-dimer occupy reaction channels for ten to twenty minutes, so a run dominated by these tests delivers far fewer results per hour than the headline clotting time figure. Ask for throughput measured on a mix similar to your own.

Request a quotation for the High-Throughput Automated Coagulation Analyzer