Water Aspirator Vacuum Pump
水流抽气真空泵
- SKU VAP-0002
- Vacuum Pumps
- ISO 9001 manufacturing (to be confirmed)
- Material conformity (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Ultimate vacuum | 10–25 mbar at 15 °C water |
|---|---|
| Air flow rate | 5–15 L/min per way |
| Number of ways | 1–4 |
| Water consumption | 3–8 L/min |
| Water supply pressure | 1–4 bar |
| Body material | Polypropylene, PTFE or metal |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61326-1, ISO 21360
What is the Water Aspirator Vacuum Pump?
A water aspirator vacuum pump uses flowing tap water through a Venturi to draw a modest vacuum of about 10 to 25 mbar. It is inexpensive and simple, used for filtration, distillation and general aspiration where water supply is available.
What is the Water Aspirator Vacuum Pump?
A water aspirator vacuum pump uses flowing tap water through a Venturi to draw a modest vacuum of about 10 to 25 mbar. It is inexpensive and simple, used for filtration, distillation and general aspiration where water supply is available.
Overview
The water aspirator, also called a water jet pump, has no motor. Tap water flows through a narrowing nozzle, accelerates and creates a low-pressure zone that draws gas from the connected vessel. Achievable vacuum is limited by the vapor pressure of water, around 10 to 25 mbar at typical supply temperatures, and improves slightly with colder water. Flow rate depends on supply pressure and is often 5 to 15 L/min of aspirated air per unit. Units may be single or multi-way, made from polypropylene, PTFE or corrosion-resistant metal, and are often fitted to a tap with a hose. Advantages are low cost, no electricity, no oil and good solvent tolerance. Disadvantages are continuous water use, dependence on supply pressure, contamination of the water with solvent vapor, and the risk of water being drawn back into the vessel if pressure is lost.
How does it work?
A laboratory vacuum pump removes gas from a sealed vessel to lower the pressure. Diaphragm pumps flex a membrane with check valves, drawing gas in and expelling it without oil, which suits filtration, aspiration and general laboratory work. Rotary vane pumps use an eccentric rotor with sliding vanes to trap and compress gas, giving a deeper vacuum for rotary evaporation and drying, but they need oil and protection against solvent vapor. Water aspirators use a Venturi effect in flowing tap water and are inexpensive but consume water and reach only a modest vacuum. In each case the pump is matched to a receiver, trap and gauge, and solvent or acid vapor must be trapped before it reaches the pump. Flow rate, ultimate pressure and chemical compatibility define performance.
What are the key features?
- No motor, no electricity and no oil required
- Venturi design reaches about 10–25 mbar
- Single or multi-way polypropylene or PTFE bodies
- Good tolerance of solvent vapors
- Low purchase cost and simple installation
- Optional non-return valve to prevent water backflow
What are the technical specifications?
A typical water aspirator vacuum pump configuration offers ultimate vacuum of 10–25 mbar at 15 °C water, air flow rate of 5–15 L/min per way, number of ways of 1–4, water consumption of 3–8 L/min, water supply pressure of 1–4 bar and body material of Polypropylene, PTFE or metal. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Water Aspirator Vacuum Pump is used in vacuum filtration, simple vacuum distillation, aspiration of liquids, general laboratory suction and teaching laboratory demonstrations. Across the wider Vacuum Pumps class, laboratories also deploy it for vacuum filtration and solid-phase extraction, rotary evaporation and solvent recovery and vacuum oven drying and degassing.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61326-1, ISO 21360, EN 12469 and GB 4793.1. Certification candidates for this model are ISO 9001 manufacturing and Material conformity; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Always fit a liquid trap between the vessel and the pump so that condensate or foam cannot enter the pump head. For solvent work, add a cold trap or an acid-resistant inline filter and change the pump oil regularly, watching for discoloration or emulsion. Vent the exhaust away from the operator when pumping hazardous vapors. Check diaphragms and valves on the maintenance schedule, since they are the usual wear points, and keep spare parts. Mount the pump on a stable surface with adequate ventilation, and confirm the electrical supply and, where required, use a pump rated for the ambient conditions. Follow IEC 61010-1 for electrical safety. Verify the achieved vacuum with a gauge rather than assuming the rated value, and record it for method consistency.
How do I select the right Water Aspirator Vacuum Pump?
Use a water aspirator only where tap water is available and water consumption is acceptable, and where the modest vacuum it produces is sufficient. For oil-free, dry operation, choose a diaphragm pump instead. Always fit a non-return valve and a trap to protect the sample.
How does it compare with other Vacuum Pumps variants?
Choose by the required vacuum level and the vapor being pumped. For filtration, aspiration and vacuum concentration where a moderate vacuum is enough, an oil-free diaphragm pump is usually the right choice, because it needs little maintenance and cannot backstream oil. For rotary evaporation, gel drying and vacuum ovens that need a deeper vacuum, a chemically resistant rotary vane pump with a cold trap and oil mist filter works well. Use a water aspirator only where tap water is available and water use is acceptable. Then match the free-air flow rate to the system volume and the speed of operation you need, and confirm the pump can start against the load. Check wetted materials and diaphragm or vane materials for solvent and acid compatibility, noise level, and whether a gauge, regulator or vacuum controller is included.
Full specifications
| Ultimate vacuum | 10–25 mbar at 15 °C water |
|---|---|
| Air flow rate | 5–15 L/min per way |
| Number of ways | 1–4 |
| Water consumption | 3–8 L/min |
| Water supply pressure | 1–4 bar |
| Body material | Polypropylene, PTFE or metal |
| Inlet connection | Hose barb, 8–12 mm |
| Non-return valve | Recommended optional |
| Weight | 0.3–1.5 kg |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Vacuum filtration
- Simple vacuum distillation
- Aspiration of liquids
- General laboratory suction
- Teaching laboratory demonstrations
Key features
- No motor, no electricity and no oil required
- Venturi design reaches about 10–25 mbar
- Single or multi-way polypropylene or PTFE bodies
- Good tolerance of solvent vapors
- Low purchase cost and simple installation
- Optional non-return valve to prevent water backflow
Frequently asked questions about Water Aspirator Vacuum Pump
About 10 to 25 mbar at normal water temperature, because the achievable vacuum is limited by the vapor pressure of water. Colder water gives a slightly deeper vacuum.
Yes, if the supply pressure falls suddenly. Fit a non-return valve and keep the vessel above the aspirator, or use a buffer flask, to prevent contamination of the sample.
It tolerates solvent vapor and is often used for simple distillations and rotovap work, but the solvent is discharged into the drain, which may breach local disposal rules. Capture or treat the effluent where required.
Choose oil-free for filtration, aspiration and general work where a moderate vacuum is enough and maintenance should be simple. Choose an oil-sealed rotary vane pump for deeper vacuum in rotary evaporation, drying and ovens, adding a cold trap to protect the oil.
Fit a cold trap and, where needed, an activated carbon or acid trap between the vessel and the pump. Keep the trap cold and empty it regularly. For oil-sealed pumps, change the oil when it darkens or emulsifies.
Match the free-air flow rate to the funnel and flask volume and to the filtration speed. A pump of about 10 to 30 L/min suits most single-place filtration, while multi-place manifolds need higher flow or several pumps.