Programmable Vacuum Drying Oven
可编程真空干燥箱
- SKU VAO-0003
- Vacuum Ovens
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Chamber volume | 25–100 L |
|---|---|
| Temperature range | RT+10 to 250 C |
| Ultimate vacuum | ≤133 Pa |
| Programs | 10–30 |
| Segments per program | Up to 30 |
| Ramp rate | 0.1–5 C/min |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, DIN 12880
What is the Programmable Vacuum Drying Oven?
A programmable vacuum drying oven stores multi-step temperature, vacuum and time profiles so drying cycles can be repeated exactly. It is chosen when a defined recipe must be validated, documented and run unattended.
What is the Programmable Vacuum Drying Oven?
A programmable vacuum drying oven stores multi-step temperature, vacuum and time profiles so drying cycles can be repeated exactly. It is chosen when a defined recipe must be validated, documented and run unattended.
Overview
This variant adds a multi-segment controller to the standard vacuum chamber, storing 10 to 30 programs with ramp, soak and vacuum steps, each with its own setpoint and duration. The controller can switch a vacuum valve or pump, ramp temperature at a controlled rate, and hold stages until a set time elapses. Data logging records temperature, pressure and step transitions for validation and traceability, often with RS-485, USB or Ethernet output. Real-time or historical curves can be shown on the display. Typical chambers are 25 to 100 liters, and temperature reaches 250 C with vacuum to 133 Pa. It suits regulated and process-development work where operator-independent reproducibility and records are essential.
How does it work?
A vacuum oven removes air from a sealed chamber with a pump, lowering the boiling point of water and solvents so evaporation proceeds quickly at moderate temperature. The chamber is a thick-walled vessel, usually stainless steel, with a reinforced door, silicone or fluororubber gasket and a transparent window. Heating comes from elements in the walls, a water or oil jacket, or heated shelves, so most heat reaches the sample by conduction and radiation rather than convection. A Pt100 sensor and PID controller hold the setpoint, while a vacuum gauge or sensor displays chamber pressure. Cold traps, solvent recovery units and inert-gas purge connections can be added for solvent-laden samples. The mild cycle protects thermolabile and easily oxidized materials.
What are the key features?
- Multi-segment controller with 10 to 30 stored programs
- Programmable ramp, soak and vacuum stages
- Data logging with RS-485, USB or Ethernet output
- Real-time and historical curve display
- Independent over-temperature protection
- Optional solvent recovery and cold trap connections
What are the technical specifications?
A typical programmable vacuum drying oven configuration offers chamber volume of 25–100 L, temperature range of RT+10 to 250 C, ultimate vacuum of ≤133 Pa, programs of 10–30, segments per program of Up to 30 and ramp rate of 0.1–5 C/min. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Programmable Vacuum Drying Oven is used in validated drying cycles, process development and scale-up studies, pharmaceutical sample preparation and materials degassing and curing. Across the wider Vacuum Ovens class, laboratories also deploy it for heat-sensitive powder drying, degassing of liquids and resins and drying electronic and optical components.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, DIN 12880, ISO 9001 and GB/T 30435. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Vacuum ovens need a compatible pump, usually a rotary-vane or dry pump, and for solvent work a cold trap to protect the pump and recover vapour. Never use a vacuum oven as a pressure vessel, and never open the door until the chamber is vented to atmosphere. Place the oven on a stable surface with pump clearance and route exhaust safely. Calibrate temperature and verify vacuum tightness periodically, checking the door gasket for wear and replacing it as needed. Clean shelves and chamber after solvent use, and keep a log of pump oil changes or dry-pump service.
How do I select the right Programmable Vacuum Drying Oven?
Select a programmable vacuum oven when the drying recipe must be documented and reproduced, or when the cycle must run unattended overnight. Simple drying of one material rarely justifies it. In the RFQ, specify number of programs and segments, ramp rates, data interface, records format and whether vacuum switching is controlled by the oven.
How does it compare with other Vacuum Ovens variants?
Choose a vacuum oven when the sample degrades at the drying temperature, oxidizes in air, or contains a solvent that must be recovered. Start with chamber volume and shelf area against batch size, then set temperature range, usually up to 200 or 250 C, and the required ultimate vacuum, from about 133 Pa for general drying to below 10 Pa for demanding work. Decide whether you need heated shelves for better conduction or a jacket-heated chamber. Check the gasket and window material if aggressive solvents are used, and specify a cold trap or solvent recovery unit. Confirm pump compatibility, controller profile, safety interlocks and electrical supply.
Full specifications
| Chamber volume | 25–100 L |
|---|---|
| Temperature range | RT+10 to 250 C |
| Ultimate vacuum | ≤133 Pa |
| Programs | 10–30 |
| Segments per program | Up to 30 |
| Ramp rate | 0.1–5 C/min |
| Data interface | RS-485, USB or Ethernet |
| Temperature uniformity | ±2–3 C |
| Heating power | 1–2.5 kW |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Validated drying cycles
- Process development and scale-up studies
- Pharmaceutical sample preparation
- Materials degassing and curing
Key features
- Multi-segment controller with 10 to 30 stored programs
- Programmable ramp, soak and vacuum stages
- Data logging with RS-485, USB or Ethernet output
- Real-time and historical curve display
- Independent over-temperature protection
- Optional solvent recovery and cold trap connections
Frequently asked questions about Programmable Vacuum Drying Oven
Most models store 10 to 30 programs with up to 30 segments each, covering temperature ramps, soaks and vacuum steps. Programs are named or numbered so the correct recipe can be selected quickly during routine operation.
A controlled ramp avoids thermal shock and solvent bumping, and it makes the heating history reproducible. Fast uncontrolled heating can crack powders, distort parts or drive solvent off too quickly and overload the pump.
Yes. Data logging records temperature, vacuum and stage transitions with timestamps, exported through RS-485, USB or Ethernet. This supports validation and traceability requirements, but the recording system must itself be qualified and access-controlled where data integrity rules apply.
Under vacuum, water and solvents boil at lower temperature, so samples dry faster and at lower heat, with less oxidation. This protects thermolabile, oxygen-sensitive and reactive materials that would degrade in a conventional oven.
Typical chambers reach about 133 Pa with a rotary-vane pump, and below 10 Pa with a two-stage pump and good seals. Practical working pressure also depends on the vapour load, so drying usually occurs at a few hundred to a few thousand pascals.
A cold trap is recommended whenever solvents or large amounts of water are evaporated. It condenses vapour before it reaches the pump, protecting pump oil and seals and allowing solvent recovery. It is less critical for dry, low-vapour samples.