Handheld Urine Strip Reader
手持式尿条读取仪
- SKU USR-0005
- Urine Strip Readers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA class II registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measured parameters | Standard 10 parameters |
|---|---|
| Wavelengths | Three to four fixed wavelengths |
| Reading time | 3–8 s after insertion |
| Battery | Rechargeable, 100–300 readings per charge |
| Display | Colour display with categorical results |
| Data storage | 500 results with date and time |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI GP16, CLSI EP05
What is the Handheld Urine Strip Reader?
A handheld urine strip reader is a pocket-sized device that reads one strip at a time with battery power and displays or transmits the result. It suits very low volume testing, house calls and settings where a bench instrument is impractical.
What is the Handheld Urine Strip Reader?
A handheld urine strip reader is a pocket-sized device that reads one strip at a time with battery power and displays or transmits the result. It suits very low volume testing, house calls and settings where a bench instrument is impractical.
Overview
The device contains miniature LEDs and a photodiode with a slot for the strip, a small screen and a rechargeable battery, and it may connect to a phone or computer for result storage. Reading time is a few seconds once the strip is inserted, and the software applies stored calibration for the strip type. Because the optical path is small, cleaning the slot after each use is important, and strips must be inserted fully and at the correct orientation. Precision is generally lower than a bench reader, so the device is best used for screening or for qualitative decisions, with confirmation on a laboratory instrument when a numerical result or a permanent record is required.
How does it work?
Each pad on a reagent strip contains reagents that change colour in proportion to the analyte concentration: glucose pads use a peroxidase-chromogen system, protein pads rely on the protein error of a pH indicator, blood pads detect the pseudoperoxidase activity of haemoglobin, leukocyte esterase cleaves an ester to release a diazonium-reactive compound, and nitrite is detected by diazotisation. The reader presses the strip against a light source and measures the light reflected from each pad with photodiodes or a camera at defined wavelengths, usually between 525 and 660 nanometres. A compensation pad or channel corrects for the intrinsic colour of the urine, and some instruments also compensate for ascorbic acid interference. The instrument converts reflectance into a category such as negative, trace, 1+, 2+, 3+ or a numeric value for pH and specific gravity.
What are the key features?
- Pocket-sized housing with a strip slot and small display
- Rechargeable battery with USB charging
- Miniature LED optics with stored calibration per strip type
- Optional connection to a phone or computer for storage
- Slot cleaning required after each use
- Screening accuracy suitable for qualitative decisions
What are the technical specifications?
A typical handheld urine strip reader configuration offers measured parameters of Standard 10 parameters, wavelengths of Three to four fixed wavelengths, reading time of 3–8 s after insertion, battery of Rechargeable, 100–300 readings per charge, display of Colour display with categorical results and data storage of 500 results with date and time. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Handheld Urine Strip Reader is used in house calls and home care testing, very low volume clinic testing, field screening where transport of equipment is limited and personal health monitoring under supervision. Across the wider Urine Strip Readers class, laboratories also deploy it for routine urine chemistry screening in clinics, antenatal and pre-employment health checks and diabetes and renal clinic monitoring.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI GP16, CLSI EP05, CLSI POCT04, ISO 18113-1, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Read strips within the time stated in the instructions, because pad colour continues to develop and delays change results near category boundaries. Protect strips from moisture, heat and light, do not touch the pads and use them before expiry, since degraded strips give falsely negative results. Verify performance at installation with the manufacturer's calibration strip or reference panel, and run quality control material or a known urine sample each working day. Clean the reading window and strip carrier according to the manual, and check that the compensation channel is functioning, because a dirty window biases all reflectance readings. Treat urine as potentially infectious and decontaminate the strip carrier regularly.
How do I select the right Handheld Urine Strip Reader?
Specify this variant only when portability is the decisive requirement and testing volume is very low. In the RFQ confirm the strip types supported, whether results can be exported for record keeping, the battery specification and how the slot is cleaned, because contamination in the small optical path is the main failure mode.
How does it compare with other Urine Strip Readers variants?
Decide first how many strips are read each day, because that determines whether a simple bench reader, an instrument with automatic strip feeding or a portable device is appropriate. Then check which parameters the reader measures and whether the report format matches what clinicians expect, especially if semiquantitative scales differ from other laboratories. Confirm the wavelengths and compensation features, since colour and ascorbate interference are the main sources of error, and check whether barcode or operator identification is supported for traceability. For portable and near-patient use, consider battery life, strip storage conditions and whether the device can transmit results. Confirm that the reagent strips specified for the reader are available locally and have an adequate shelf life.
Full specifications
| Measured parameters | Standard 10 parameters |
|---|---|
| Wavelengths | Three to four fixed wavelengths |
| Reading time | 3–8 s after insertion |
| Battery | Rechargeable, 100–300 readings per charge |
| Display | Colour display with categorical results |
| Data storage | 500 results with date and time |
| Connectivity | USB or Bluetooth to phone or computer |
| Weight | 100–250 g |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- House calls and home care testing
- Very low volume clinic testing
- Field screening where transport of equipment is limited
- Personal health monitoring under supervision
Key features
- Pocket-sized housing with a strip slot and small display
- Rechargeable battery with USB charging
- Miniature LED optics with stored calibration per strip type
- Optional connection to a phone or computer for storage
- Slot cleaning required after each use
- Screening accuracy suitable for qualitative decisions
Frequently asked questions about Handheld Urine Strip Reader
They are suitable for screening and for qualitative decisions such as the presence or absence of blood, glucose or nitrite. For diagnosis and monitoring, borderline or unexpected results should be confirmed on a laboratory analyzer, and the device should be included in the laboratory's quality management system.
Wipe the slot with a soft cloth moistened with the solution specified by the manufacturer after each use, and inspect for lint or deposits. Contamination or scratches scatter light and shift results, and visible damage should lead to service rather than continued use.
Typical practice is one hundred to three hundred readings per charge, depending on display brightness and whether wireless transfer is used. Batteries in small devices should be charged regularly rather than left fully discharged, and the charge status should be checked before field use.
Yes. Verify with a control strip or a sample of known composition at defined intervals, record the outcome, and repeat the check if the device is dropped or exposed to extreme temperature. Where the device is used for screening only, verification frequency can be lower but must still be documented.
A reader measures reflectance at defined wavelengths and compares it with stored calibration data, which removes some subjectivity in colour matching and prevents transcription errors when results are printed or transmitted. Visual reading is acceptable when the reader is unavailable, but requires trained staff and a printed colour chart.
Most measure glucose, protein, blood, leukocyte esterase, nitrite, ketones, bilirubin, urobilinogen, pH and specific gravity, and some add ascorbate, microalbumin, creatinine or calcium. The pad menu is determined by the strip used, so the reader must support the strips available in your market.
Strongly coloured urine changes the light reflected from every pad, which can shift several parameters in the same direction. Readers with a compensation pad or channel correct for this effect automatically, but very dark samples should be reported with a comment and the result verified by another method when clinically important.