Hydrocarbon-Refrigerant Ultra-Low Freezer with Low Global Warming Potential
低全球变暖潜能值碳氢制冷剂超低温冷冻箱
- SKU ULF-0005
- Ultra-Low Freezers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 60335-2-89 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | -50 to -86 °C |
|---|---|
| Net capacity | 300-700 L |
| High-stage refrigerant | R290 (propane) |
| Low-stage refrigerant | R170 (ethane) or ethane-propane blend |
| Global warming potential | Below 5 |
| Refrigerant charge | Within IEC 60335-2-89 limits |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-2-011, IEC 60335-2-89, ENERGY STAR Laboratory Grade Freezers
What is the Hydrocarbon-Refrigerant Ultra-Low Freezer with Low Global Warming Potential?
An ultra-low freezer using natural hydrocarbon refrigerants such as R290 and R170 in its cascade circuits. It meets -86 °C performance with very low global warming potential and supports organizations with refrigerant phase-down requirements.
What is the Hydrocarbon-Refrigerant Ultra-Low Freezer with Low Global Warming Potential?
An ultra-low freezer using natural hydrocarbon refrigerants such as R290 and R170 in its cascade circuits. It meets -86 °C performance with very low global warming potential and supports organizations with refrigerant phase-down requirements.
Overview
This variant replaces high-GWP fluorinated refrigerants with hydrocarbons such as propane (R290) in the high stage and ethane (R170) or an ethane-propane blend in the low stage. The global warming potential of these gases is close to zero, compared with thousands for some HFCs, which matters as regional regulations phase down HFC supply. Charges are kept to the small quantities permitted by IEC 60335-2-89 for flammable refrigerants, and components such as relays and fans are designed or placed to avoid ignition. Performance is comparable with conventional cascades and efficiency is often better. Service requires technicians trained in flammable refrigerant handling. The freezer suits institutions with sustainability targets and sites anticipating HFC restrictions.
How does it work?
Ultra-low freezers maintain -86 °C by cascade refrigeration or by single-stage mixed-refrigerant circuits. In a cascade, a high-stage compressor and condenser cool the condenser of a low-stage circuit in a heat exchanger, so the low stage evaporates a low-boiling refrigerant, often a hydrocarbon or fluorinated blend, at roughly -100 °C. Vacuum insulation panels combined with polyurethane foam reduce conductive heat gain and allow more interior volume per footprint. Variable-speed or dual-compressor systems adjust capacity to the load, lowering energy use and temperature swings. A controller monitors multiple sensors and drives alarms for temperature, door, power failure and compressor faults. Many models include a backup port for CO2 or LN2, a pressure-equalization valve to release door vacuum, and network outputs for central monitoring.
What are the key features?
- R290 and R170 cascade circuits have near-zero global warming potential.
- Small refrigerant charge complies with limits for flammable refrigerants.
- Ignition-safe relays and fan motors are used in the compressor compartment.
- Cooling performance is comparable with conventional cascades.
- Supports refrigerant phase-down and sustainability reporting.
- Service labels and leak guidance are supplied with the unit.
What are the technical specifications?
A typical hydrocarbon-refrigerant ultra-low freezer with low global warming potential configuration offers temperature range of -50 to -86 °C, net capacity of 300-700 L, high-stage refrigerant of R290 (propane), low-stage refrigerant of R170 (ethane) or ethane-propane blend, global warming potential of Below 5 and refrigerant charge of Within IEC 60335-2-89 limits. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Hydrocarbon-Refrigerant Ultra-Low Freezer with Low Global Warming Potential is used in sustainability-led institutions, laboratories anticipating HFC restrictions, universities with carbon reporting and public-sector biobanks. Across the wider Ultra-Low Freezers class, laboratories also deploy it for biobank long-term archives, vaccine and biologics development and genomics and sequencing sample storage.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-2-011, IEC 60335-2-89, ENERGY STAR Laboratory Grade Freezers, ASHRAE 72, ISO 20387, ISO 23953 and GB/T 21151. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 60335-2-89 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Plan the room before delivery. A large ultra-low freezer rejects 1 to 2 kW of heat, so provide ventilation or air conditioning, keep ambient at or below 32 °C and maintain 200 to 300 mm clearance. Use a dedicated circuit, ideally on emergency power, with surge protection. Check that doors and corridors allow the freezer to pass. After placement, let the unit rest for 24 hours, then run empty until stable before loading in stages. Clean filters monthly, inspect gaskets, and calibrate sensors annually. Keep a maintained spare freezer or reserve space, and test alarms and backup systems at least quarterly. Record energy use and temperature trends to detect compressor wear early.
How do I select the right Hydrocarbon-Refrigerant Ultra-Low Freezer with Low Global Warming Potential?
Select the hydrocarbon variant where low GWP or HFC phase-down is a selection criterion. Conventional units may suit sites with no such requirement. Specify refrigerant types, charge declaration, safety test report, service provider qualification and disposal procedure.
How does it compare with other Ultra-Low Freezers variants?
Choose an ultra-low freezer when you need -86 °C capability, high capacity or strong energy performance rather than a basic -80 °C unit. First define capacity in box positions, including 25 percent growth and a reserve equal to one freezer. Compare energy use measured under a standard method, because a large unit can consume 10 to 20 kWh daily and energy cost often exceeds purchase price over its life. Review insulation type, compressor redundancy, noise and heat output, as these affect room cooling. For critical collections look at dual compressors or sensors, backup ports and remote monitoring. Check door and rack design for ease of access and confirm footprint, including stacking options. Verify ambient rating and electrical supply at your site.
Full specifications
| Temperature range | -50 to -86 °C |
|---|---|
| Net capacity | 300-700 L |
| High-stage refrigerant | R290 (propane) |
| Low-stage refrigerant | R170 (ethane) or ethane-propane blend |
| Global warming potential | Below 5 |
| Refrigerant charge | Within IEC 60335-2-89 limits |
| Pull-down time | 6-9 h from 25 °C to -80 °C, empty |
| Ambient rating | 10-32 °C |
| Energy use at -80 °C | About 8-14 kWh/day |
| Service requirement | Technician trained in flammable refrigerants |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Sustainability-led institutions
- Laboratories anticipating HFC restrictions
- Universities with carbon reporting
- Public-sector biobanks
Key features
- R290 and R170 cascade circuits have near-zero global warming potential.
- Small refrigerant charge complies with limits for flammable refrigerants.
- Ignition-safe relays and fan motors are used in the compressor compartment.
- Cooling performance is comparable with conventional cascades.
- Supports refrigerant phase-down and sustainability reporting.
- Service labels and leak guidance are supplied with the unit.
Frequently asked questions about Hydrocarbon-Refrigerant Ultra-Low Freezer with Low Global Warming Potential
The refrigerants are flammable, but the charge is small and the sealed circuit and electrical parts are designed to meet IEC requirements. Normal use is safe, and only trained staff should open refrigerant circuits.
Yes, in general. Hydrocarbon cascades reach the same -86 °C and often show better energy efficiency. Verify test data for the specific model.
Leaked refrigerant contributes to climate change in proportion to its GWP. Low-GWP gases reduce that impact, and many regions regulate HFC supply under the Kigali Amendment.
An ultra-low freezer is the high-specification version, reaching -86 °C with larger capacity, better energy performance and more security features. A basic -80 °C freezer holds similar storage temperature with simpler design and lower purchase cost.
Large units typically use 10 to 20 kWh per day, while energy-efficient models with vacuum insulation and variable-speed compressors may use 30 to 50 percent less. Compare values measured under the same standard test.
Some compact models are designed to stack two high with a stacking kit, saving floor space. Check weight, vibration, ventilation and ceiling height, and only stack models approved for it.