Skip to main content
Lab Manufacturers China
Bottle Roller Mixer for Cell Culture Vessels — product photo

Bottle Roller Mixer for Cell Culture Vessels

细胞培养滚瓶混合器

  • SKU TMI-0002
  • Tube Mixers
  • CE (to be confirmed)
  • RoHS (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Speed range0.2–20 rpm
Bottle capacity100 mL–2 L
Number of bottles2–10
Roller diameter40–60 mm
Maximum load10–25 kg
DirectionClockwise, reversible on selected models
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-051, EN 61326-1

What is the Bottle Roller Mixer for Cell Culture Vessels?

A bottle roller mixer rotates cylindrical bottles, roller bottles and media bottles on heavy-duty rollers at low speed. It suits cell culture, fermentation seed preparation and media dissolution where large vessels must be kept in suspension.

What is the Bottle Roller Mixer for Cell Culture Vessels?

A bottle roller mixer rotates cylindrical bottles, roller bottles and media bottles on heavy-duty rollers at low speed. It suits cell culture, fermentation seed preparation and media dissolution where large vessels must be kept in suspension.

Overview

The bottle roller mixer uses heavier rollers and a stronger gear motor than a tube roller. A rack or frame holds two to ten roller bottles or media bottles of 100 mL to 2 L, which rotate at 0.2 to 20 rpm. Low speeds are typical for cell culture roller bottles, where cells adhere to the inner wall and are bathed in medium as the bottle turns. Some models include an incubator-compatible design with a separate controller and a cable that passes through the door seal. Maximum load can reach 10 to 25 kg. Rollers are coated to grip glass or plastic, and guides keep bottles aligned. A timer and reversible direction are available on better units. The mixer is slower and more rugged than tube rollers and is chosen for upstream biological work.

How does it work?

Tube mixers use a motor-driven mechanism to move containers in a slow, repeating pattern. Roller mixers have parallel rollers, typically 4 to 8, that turn tubes or bottles about their own axis so liquid spreads over the inner wall. Rocking mixers have a platform tilted up and down around a horizontal axis, which moves liquid back and forth across the vessel. Seesaw or 3D rockers combine tilt and rotation in a wave-like motion. Reciprocating versions move a tray linearly. Speeds are low, from 5 to 80 cycles or rpm, and tilt angles are around 5 to 20 degrees. Components include a DC or AC gear motor, drive shaft or cam, platform or rollers, a speed controller, a timer, and non-slip mats or holders. Because forces are gentle, the mixers are suited to cells, blood and protein solutions that would be damaged by vortexing.

What are the key features?

  • Heavy-duty rollers coated to grip glass and plastic bottles
  • Speed range of about 0.2–20 rpm for roller-bottle culture
  • Handles 100 mL to 2 L bottles, two to ten at a time
  • Incubator-compatible design with external controller option
  • Bottle guides keep containers aligned during rotation
  • Load capacity of 10–25 kg for heavy media bottles

What are the technical specifications?

A typical bottle roller mixer for cell culture vessels configuration offers speed range of 0.2–20 rpm, bottle capacity of 100 mL–2 L, number of bottles of 2–10, roller diameter of 40–60 mm, maximum load of 10–25 kg and direction of Clockwise, reversible on selected models. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Bottle Roller Mixer for Cell Culture Vessels is used in roller-bottle cell culture, culture media dissolution, fermentation seed preparation and environmental sample suspension. Across the wider Tube Mixers class, laboratories also deploy it for blood tube and sample mixing, cell culture roller bottles and western blot staining and washing.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-051, EN 61326-1, GB 4793.1 and CLSI GP41. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the mixer on a flat, stable surface with enough clearance for the moving platform or rollers. Keep loads within the rated limit and distribute them evenly to protect bearings and gear motors. Use non-slip mats or holders for bottles and tubes, and keep caps tight to prevent leaks into the drive. If operated in incubators, confirm the rating for humidity and temperature and use a remote controller where available. Clean mats and platforms with mild disinfectant and check for cracks. Periodically verify speed with a tachometer and record results if your quality system requires it. Electrical safety should follow IEC 61010-1, and instruments for cell culture should be made from materials that tolerate disinfectants and UV where used.

How do I select the right Bottle Roller Mixer for Cell Culture Vessels?

Choose a bottle roller mixer for roller-bottle culture and for large media bottles that a tube roller cannot carry. Specify bottle diameter and length, number of bottles, speed range, load, incubator use and whether reverse direction is required in the RFQ.

How does it compare with other Tube Mixers variants?

Choose a tube mixer by motion type, container format, speed and load. Roller mixers suit tubes, bottles and cell culture roller bottles, and they provide continuous gentle mixing for viscous or settling samples. Rocking mixers suit flat vessels, gels, blots and staining trays where liquid should wash across a surface. Seesaw or 3D rockers provide a wave motion for blots and multiple plates. Check the maximum load, because large bottles can reach several kilograms. Confirm that speed and tilt angle are adjustable, and that the platform or rollers are compatible with your vessels. For incubator or cold-room use, verify temperature and humidity ratings. Timers, reversible direction and program memory matter if protocols are standardized. Also consider cleanability, noise and whether a removable mat or roller set is needed.

Full specifications

Full specifications
Speed range0.2–20 rpm
Bottle capacity100 mL–2 L
Number of bottles2–10
Roller diameter40–60 mm
Maximum load10–25 kg
DirectionClockwise, reversible on selected models
TimerUp to 99 h or continuous
Motor typeDC gear motor
Operating temperature4–40 °C
Humidity toleranceUp to 85 % RH non-condensing
Power supply100–240 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Roller-bottle cell culture
  • Culture media dissolution
  • Fermentation seed preparation
  • Environmental sample suspension

Key features

  • Heavy-duty rollers coated to grip glass and plastic bottles
  • Speed range of about 0.2–20 rpm for roller-bottle culture
  • Handles 100 mL to 2 L bottles, two to ten at a time
  • Incubator-compatible design with external controller option
  • Bottle guides keep containers aligned during rotation
  • Load capacity of 10–25 kg for heavy media bottles

Frequently asked questions about Bottle Roller Mixer for Cell Culture Vessels

Roller-bottle cultures typically rotate at 0.2 to 2 rpm to allow adherent cells to be bathed in medium. Higher speeds are used for mixing media or dissolving powders.

Related models

All Tube Mixers

Request a quotation for the Bottle Roller Mixer for Cell Culture Vessels

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote