Wilhelmy Plate Tensiometer for Equilibrium and Interfacial Tension
平衡与界面张力用 Wilhelmy 板法张力仪
- SKU STM-0002
- Surface Tension Meters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measuring range | 0–1000 mN/m |
|---|---|
| Resolution | 0.001 mN/m |
| Accuracy | ±0.05 mN/m |
| Plate dimensions | 10 × 20 × 0.2 mm |
| Balance resolution | 0.01 mg |
| Temperature range | 5–90 °C, ±0.1 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 304, ASTM D1331, ASTM D971
What is the Wilhelmy Plate Tensiometer for Equilibrium and Interfacial Tension?
A force tensiometer that holds a roughened platinum plate at the liquid surface and records the wetting force continuously, so no geometric correction is needed. It suits time-dependent adsorption, CMC curves and liquid–liquid interfacial tension with automatic dosing.
What is the Wilhelmy Plate Tensiometer for Equilibrium and Interfacial Tension?
A force tensiometer that holds a roughened platinum plate at the liquid surface and records the wetting force continuously, so no geometric correction is needed. It suits time-dependent adsorption, CMC curves and liquid–liquid interfacial tension with automatic dosing.
Overview
In the plate method a thin platinum plate, typically 10 mm wide and 0.1 to 0.2 mm thick with roughened surface to ensure zero contact angle, is suspended from a microbalance and contacts the liquid surface. The wetting force F equals tension multiplied by the wetted perimeter times the cosine of the contact angle, which is one for a fully wetted plate, so tension is F divided by the perimeter with no further correction. The surface is not disturbed, so the plate can follow changes over minutes or hours, a clear advantage for surfactant adsorption and aging studies. Automatic dosing units add concentrated solution to build a CMC curve in a single run. Liquid–liquid interfacial tension is measured by moving the plate through the interface.
How does it work?
Surface tension arises from the cohesive energy imbalance of molecules at a liquid surface. Force tensiometers measure the force needed to detach a platinum ring (du Noüy) from the surface, or the pull exerted on a fully wetted platinum plate (Wilhelmy), and convert it to tension using a correction factor or geometry. Pendant drop analyzers photograph a hanging drop and fit its shape with the Young–Laplace equation, where gravity elongates the drop in proportion to tension. Bubble pressure tensiometers measure the maximum pressure required to form a bubble at a capillary tip, which gives dynamic surface tension at controlled surface age from milliseconds to seconds. Spinning drop tensiometers measure ultra-low interfacial tension from the elongation of a drop in a rotating capillary.
What are the key features?
- Roughened platinum plate with zero contact angle
- Continuous force recording without surface disturbance
- Automatic dosing for critical micelle concentration curves
- Thermostatted vessel with stirrer and temperature sensor
- Liquid–liquid interface measurement by plate immersion
- Software with surface tension versus time and concentration plots
What are the technical specifications?
A typical wilhelmy plate tensiometer for equilibrium and interfacial tension configuration offers measuring range of 0–1000 mN/m, resolution of 0.001 mN/m, accuracy of ±0.05 mN/m, plate dimensions of 10 × 20 × 0.2 mm, balance resolution of 0.01 mg and temperature range of 5–90 °C, ±0.1 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Wilhelmy Plate Tensiometer for Equilibrium and Interfacial Tension is used in CMC determination of surfactants, dynamic adsorption studies, formulation development and liquid–liquid interfacial tension. Across the wider Surface Tension Meters class, laboratories also deploy it for surfactant CMC determination, ink and coating formulation and petroleum interfacial tension.
Which standards and certifications apply?
Relevant standards and methods include ISO 304, ASTM D1331, ASTM D971, ASTM D1590 and OECD 115. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Cleanliness dominates accuracy: clean platinum rings and plates by flaming to red heat after solvent rinsing, use borosilicate vessels cleaned with chromic acid alternatives, and avoid touching surfaces with fingers. Control temperature within ±0.1 °C, because surface tension changes by roughly 0.1 to 0.2 mN/m per degree for many liquids. Level the instrument and protect it from drafts and vibration. Calibrate the balance with weights and check the system with ultrapure water, which should read about 72.0 mN/m at 25 °C. For surfactant solutions, allow equilibration time or use dynamic methods and report measurement time.
How do I select the right Wilhelmy Plate Tensiometer for Equilibrium and Interfacial Tension?
Select this variant for research and formulation labs that need time-resolved data, CMC curves or high reproducibility, and when the standard allows the plate method. In an RFQ, specify balance resolution, automatic dosing channels, temperature range and required test methods.
How does it compare with other Surface Tension Meters variants?
Choose by what must be measured and the sample. Equilibrium surface and interfacial tension of pure liquids, solvents and most formulations suit a plate or ring tensiometer, with the plate preferred for time-dependent or interfacial work because it needs no correction. Small volumes, high temperature, high pressure or opaque liquids suit pendant drop. Fast surfactant adsorption and inks, where new surfaces form in milliseconds, need a bubble pressure instrument. Interfacial tension below 0.1 mN/m, common in enhanced oil recovery and microemulsions, needs a spinning drop instrument. Check the measuring range, resolution, temperature control, automation, and standards such as ISO 304, ASTM D1331, ASTM D971 or ASTM D1590 for the procedure you must follow.
Full specifications
| Measuring range | 0–1000 mN/m |
|---|---|
| Resolution | 0.001 mN/m |
| Accuracy | ±0.05 mN/m |
| Plate dimensions | 10 × 20 × 0.2 mm |
| Balance resolution | 0.01 mg |
| Temperature range | 5–90 °C, ±0.1 °C |
| Dosing accuracy | ±0.5% of volume |
| Sample volume | 10–80 mL |
| Measurement types | Surface and interfacial tension, CMC |
| Data output | PDF, CSV, LIMS |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- CMC determination of surfactants
- Dynamic adsorption studies
- Formulation development
- Liquid–liquid interfacial tension
Key features
- Roughened platinum plate with zero contact angle
- Continuous force recording without surface disturbance
- Automatic dosing for critical micelle concentration curves
- Thermostatted vessel with stirrer and temperature sensor
- Liquid–liquid interface measurement by plate immersion
- Software with surface tension versus time and concentration plots
Frequently asked questions about Wilhelmy Plate Tensiometer for Equilibrium and Interfacial Tension
A fully wetted plate has zero contact angle, and the vertical wetting force is directly proportional to tension and wetted length. Geometry therefore gives the result without empirical correction tables.
Surface tension is measured as surfactant concentration increases, typically using automated dosing. The CMC is the concentration at the breakpoint where the tension curve levels off, found from the intersection of two fitted lines.
A contact angle above zero gives falsely low tension. Roughened platinum flamed before use normally wets fully, and alternatives such as sandblasted plates or paper plates can be used for special samples.
Surface tension is reported in millinewtons per meter, mN/m, which equals dyn/cm. Water is about 72 mN/m at 25 °C, most organic solvents lie between 20 and 40 mN/m, and surfactant solutions can fall below 30 mN/m.
The Wilhelmy plate is widely used for equilibrium measurements and CMC determination, while bubble pressure tensiometry measures fast dynamic adsorption. Choose by whether equilibrium or time-dependent values are required.
Surface tension decreases with temperature, about 0.15 mN/m per °C for water. A uncontrolled difference of a few degrees can exceed the tolerance of a specification, so a thermostatted sample vessel is recommended.