Vacuum Head Seed Counter
真空吸头式种子计数仪
- SKU SEC-0002
- Seed Counters
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Counting principle | Vacuum suction on perforated head |
|---|---|
| Holes per head | 50 or 100 (interchangeable) |
| Seed size range | 0.5–8 mm |
| Positioning accuracy | One seed per hole confirmed |
| Vacuum source | Built-in pump or external vacuum |
| Transfer to | Tray, germination paper or packet |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISTA International Rules for Seed Testing, ISO 520 (1000-grain mass), AOSA Rules for Testing Seeds
What is the Vacuum Head Seed Counter?
A counter that holds one seed on each perforation of a suction head so an exact number can be transferred. It is the right choice for small, light or irregular seeds and for germination work requiring verified counts.
What is the Vacuum Head Seed Counter?
A counter that holds one seed on each perforation of a suction head so an exact number can be transferred. It is the right choice for small, light or irregular seeds and for germination work requiring verified counts.
Overview
The vacuum head seed counter draws air through a plate or head drilled with a regular array of holes. When the head touches a tray of seeds, one seed lodges on each hole, and the operator lifts the head and releases the vacuum above a germination tray, paper or packet so that all seeds drop in a single operation. Because the number of holes is fixed, the count is exact and can be checked visually, which is valuable for replicate germination tests and for small or sticky seeds that other counters handle poorly. Heads with different hole sizes and counts, commonly 50 or 100 per row, cover a wide range of species. The method is slower than photoelectric counting but is more reliable for difficult seeds and gives a regular spatial pattern that simplifies germination scoring. Regular cleaning of the holes and replacement of worn heads maintain accuracy.
How does it work?
Seed counters use several counting principles. Photoelectric counters drop seeds through a chute where a beam and sensor detect each seed, and pulses are totalised; the method suits round, uniform seeds. Vacuum head counters use a plate with perforations and gentle suction to pick up one seed per hole, so the operator can transfer an exact number to a tray or paper. Electronic tray counters place an image sensor beneath a grooved tray and count seeds from their shadows or contours, which handles irregular shapes and mixes. Weighing-based counters determine the number from the mass of a sample and the thousand-grain weight, which is fast but indirect. Automatic dosing systems combine counting with dispensing into packets or germination trays. Calibration with a known seed number and cleaning between species keep counts accurate.
What are the key features?
- Fixed hole array gives an exact, visually verifiable count.
- Handles small, light and sticky seeds that other counters miss.
- Interchangeable heads cover many seed sizes and counts.
- Single release drops all seeds in a regular pattern.
- Pattern simplifies germination scoring and replications.
- Simple design with easy hole cleaning and maintenance.
What are the technical specifications?
A typical vacuum head seed counter configuration offers counting principle of Vacuum suction on perforated head, holes per head of 50 or 100 (interchangeable), seed size range of 0.5–8 mm, positioning accuracy of One seed per hole confirmed, vacuum source of Built-in pump or external vacuum and transfer to of Tray, germination paper or packet. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Vacuum Head Seed Counter is used in germination test setup, small-seed replicate counting, breeding line seed handling and vegetable and flower seed work. Across the wider Seed Counters class, laboratories also deploy it for germination test sample preparation, thousand-grain weight determination and seed purity analysis.
Which standards and certifications apply?
Relevant standards and methods include ISTA International Rules for Seed Testing, ISO 520 (1000-grain mass), AOSA Rules for Testing Seeds, GB/T 3543.1 and ISTA Chapter 2 (sampling). Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Calibrate or verify the counter with a known seed number for each species before routine use, and recheck after changing settings or cleaning. Keep the counting path free of dust, chaff and broken seeds, because debris produces false counts. Control moisture and static, which cause seeds to clump and bridge, especially in small or oily species. For germination work, handle counted seeds gently to avoid damage, and record the species, variety, thousand-grain weight and count for traceability. Clean between species to prevent carry-over of small seeds, and store the instrument in a dry place. When weighing-based counting is used, verify the thousand-grain weight regularly and confirm that it still applies to the current seed lot.
How do I select the right Vacuum Head Seed Counter?
Select the vacuum head counter when an exact, verifiable number must be transferred to germination media, especially for small or irregular seeds. For high-throughput routine counting of round seeds, a photoelectric counter is faster. In an RFQ, specify the seed size range, holes per head and vacuum source.
How does it compare with other Seed Counters variants?
Choose according to seed size, shape and the required accuracy. Photoelectric counters are fast and simple for round seeds such as cereals, but irregular or very small seeds may be missed or double-counted. Vacuum head counters give exact, hand-verified numbers and suit small or sticky seeds and germination work, though throughput is lower. Image-based tray counters handle mixed and irregular seeds and can report size data at the same time. Weighing-based counters are fastest for large batches but inherit the error of the thousand-grain weight, so they suit sowing-rate estimates rather than reference counts. Consider the seed size range, throughput, whether an exact transferred number is needed, and cleaning and calibration requirements. For ISTA or national seed testing, confirm that the counting method fits the prescribed procedure.
Full specifications
| Counting principle | Vacuum suction on perforated head |
|---|---|
| Holes per head | 50 or 100 (interchangeable) |
| Seed size range | 0.5–8 mm |
| Positioning accuracy | One seed per hole confirmed |
| Vacuum source | Built-in pump or external vacuum |
| Transfer to | Tray, germination paper or packet |
| Material | Stainless steel or plastic heads |
| Cleaning | Brush or air jet for holes |
| Power supply | 220 VAC, 50 Hz |
| Operating temperature | 5–40 °C |
| Weight | 3–10 kg |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Germination test setup
- Small-seed replicate counting
- Breeding line seed handling
- Vegetable and flower seed work
Key features
- Fixed hole array gives an exact, visually verifiable count.
- Handles small, light and sticky seeds that other counters miss.
- Interchangeable heads cover many seed sizes and counts.
- Single release drops all seeds in a regular pattern.
- Pattern simplifies germination scoring and replications.
- Simple design with easy hole cleaning and maintenance.
Frequently asked questions about Vacuum Head Seed Counter
Because each hole should hold exactly one seed, the operator visually checks the loaded head before release and removes any empty or doubled holes. The regular array also makes an incomplete row immediately obvious.
Sticky or damp seeds may fail to release or may leave residue in the holes. Dry the seeds, use the correct hole size and clean the head frequently with a brush or air jet to keep every hole clear.
Seeds released in a defined grid make it easy to identify each seedling, count germination percentage without confusion and photograph the tray for records. This reduces scoring errors compared with a random pile of seeds.
For small, light or sticky seeds such as grasses, vegetables and brassicas, a vacuum head counter is most reliable because each perforation holds one seed and the operator confirms the number visually. Photoelectric counters can miss or double-count very small seeds.
Count a sample of known seed number, or weigh a known number and compare, and adjust the sensitivity or suction until the counter reads correctly. Recheck after cleaning or when switching species, and keep a record for traceability.
Moisture and static electricity make light or oily seeds stick together and bridge at the feed opening, causing under-counting. Keeping seeds dry, using an antistatic device and gentle vibration at the feed helps them separate.
Related models