Ventilated Flammable Storage Cabinet
通风型易燃品储存柜
- SKU SAF-0005
- Safety Cabinets
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Cabinet type | Ventilated flammable storage |
|---|---|
| Inlet | Low level, 100–150 mm |
| Exhaust | High level, 100–150 mm |
| Air changes | 5–20 ACH |
| Fire rating | Optional with fire dampers |
| Capacity | 30–250 L |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 14470-1 (fire safety storage cabinets), NFPA 30 (flammable and combustible liquids code), OSHA 29 CFR 1910.106 (flammable liquids)
What is the Ventilated Flammable Storage Cabinet?
A ventilated flammable storage cabinet has controlled inlet and exhaust connections to remove vapour from the cabinet. It is used where odour, exposure limits or local rules require extraction. The ventilation keeps concentrations low.
What is the Ventilated Flammable Storage Cabinet?
A ventilated flammable storage cabinet has controlled inlet and exhaust connections to remove vapour from the cabinet. It is used where odour, exposure limits or local rules require extraction. The ventilation keeps concentrations low.
Overview
This cabinet adds a low-level inlet and a high-level exhaust port, usually 100–150 mm diameter, that can be connected to a duct or filter. Extraction keeps vapour concentrations low when doors are opened and reduces odour in the laboratory, which suits volatile solvents with low exposure limits. The cabinet retains double-wall construction, self-closing doors and a spill sill, and where a fire rating is required the vent ports must be fitted with fire dampers so the rating is preserved. Airflow of 5–20 air changes per hour is typical, and the exhaust must not create a strong draught that affects the stability of nearby equipment or fume hoods. Venting is a control for vapour, not a substitute for keeping the cabinet closed.
How does it work?
A laboratory safety cabinet is a container designed to hold hazardous chemicals safely under normal use and during a fire. Flammable liquid cabinets use double walls with an air space, thermal insulation, self-closing and self-latching doors and a sill that contains spills. They keep the internal temperature below the ignition temperature of the contents for a rated period, such as 30, 60 or 90 minutes, so occupants can evacuate and the fire service can respond. Many are tested to EN 14470-1 or FM 6050, and some are vented to relieve pressure or remove vapour. Corrosive cabinets use chemically resistant linings and often ventilated extraction so acid or base vapour does not attack the cabinet or the room. Labelling, segregation by hazard class and secondary containment trays are integral to safe use, and cabinets should be closed except when loading.
What are the key features?
- Low-level inlet and high-level exhaust ports
- Port diameter 100–150 mm
- Air changes 5–20 per hour
- Fire dampers when a rating is required
- Double-wall steel with spill sill
- Reduces odour and vapour concentration
What are the technical specifications?
A typical ventilated flammable storage cabinet configuration offers cabinet type of Ventilated flammable storage, inlet of Low level, 100–150 mm, exhaust of High level, 100–150 mm, air changes of 5–20 ACH, fire rating of Optional with fire dampers and capacity of 30–250 L. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Ventilated Flammable Storage Cabinet is used in volatile solvent storage, low-exposure-limit chemicals, odour-sensitive laboratories and waste solvent accumulation. Across the wider Safety Cabinets class, laboratories also deploy it for solvent storage in chemistry laboratories, acid and base storage and pharmaceutical reagent storage.
Which standards and certifications apply?
Relevant standards and methods include EN 14470-1 (fire safety storage cabinets), NFPA 30 (flammable and combustible liquids code), OSHA 29 CFR 1910.106 (flammable liquids), FM 6050 (storage cabinets for flammable liquids), GB 15603 (chemical storage rules) and GHS labelling requirements. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place cabinets on a level, load-rated floor away from exits, heat sources and ignition points, and confirm the required distance from escape routes under local codes. Inspect doors, latches and hinges monthly and confirm self-closing and self-latching operation. Check the fire rating documentation and keep it with the asset record. If a cabinet is vented, confirm the duct does not defeat the fire rating and that the exhaust is suitable. Keep incompatible chemicals in separate cabinets, use secondary trays and never exceed the rated capacity or shelf load, since shelves may fail and spill the contents. Review stored inventory regularly and remove expired or unneeded items.
How do I select the right Ventilated Flammable Storage Cabinet?
Choose ventilation where vapour exposure limits or odour require extraction, and confirm fire dampers if a rating is needed. RFQ: chemicals, exposure limits, airflow, duct route and fire rating. Confirm airflow balance with any adjacent hoods.
How does it compare with other Safety Cabinets variants?
Select the cabinet by hazard class and quantity. For flammable liquids, confirm the fire rating and capacity in litres, and whether the cabinet must be fire rated under EN 14470-1 or listed to NFPA 30 and FM 6050. Choose a corrosive cabinet with a resistant lining and, where required, ventilation for acids or bases separately. Decide between freestanding, under-bench and ventilated versions to suit the room layout and airflow. Check door operation, sill height, shelf adjustability and load capacity, and plan secondary containment trays. Confirm that placement meets local codes, including distance from exits and ignition sources, room ventilation and signage. Document installation, inspection and any venting arrangement, and train staff to keep doors closed.
Full specifications
| Cabinet type | Ventilated flammable storage |
|---|---|
| Inlet | Low level, 100–150 mm |
| Exhaust | High level, 100–150 mm |
| Air changes | 5–20 ACH |
| Fire rating | Optional with fire dampers |
| Capacity | 30–250 L |
| Shelf load | 70–200 kg per shelf |
| Doors | Self-closing, self-latching |
| Exhaust route | Ducted or filtered |
| Material | Powder-coated steel |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Volatile solvent storage
- Low-exposure-limit chemicals
- Odour-sensitive laboratories
- Waste solvent accumulation
Key features
- Low-level inlet and high-level exhaust ports
- Port diameter 100–150 mm
- Air changes 5–20 per hour
- Fire dampers when a rating is required
- Double-wall steel with spill sill
- Reduces odour and vapour concentration
Frequently asked questions about Ventilated Flammable Storage Cabinet
It can if undamped ports create a path for heat. Fire-rated cabinets use dampers that close on heat, so the rating is preserved. Venting must follow the manufacturer's instructions.
Commonly 5–20 air changes per hour, set by the vapour loading and exposure limits. Too much airflow can cool contents or disturb nearby fume hoods, so balance is important.
Yes, a carbon filter can capture some solvent vapour where ducting is impractical, but filters have limited capacity and must be changed on schedule. Ducting to atmosphere is more reliable for heavy use.
It stores flammable liquids so that a fire outside the cabinet does not quickly heat the contents to ignition, and so that spills are contained. It is tested to a fire rating and must be closed except when loading.
Fire-rated cabinets tested to EN 14470-1 or listed to FM 6050 are preferred where a fire rating, local code or insurance requirement applies. Standard cabinets may suit small quantities where codes allow.
Usually not, unless local rules, odour or vapour requires it. Venting can defeat the fire rating if not done correctly, so it should follow the manufacturer's instructions and code requirements.