Semi-Automatic Coagulation Analyzer with Mechanical Clot Detection
机械凝固检测半自动凝血分析仪
- CE (to be confirmed)
- +2
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

光学凝固检测半自动凝血分析仪
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Detection principle | Optical scatter change, 660 nm LED |
|---|---|
| Channels | 2 or 4 parallel measurement channels |
| Incubation temperature | 37 °C ±0.3 °C |
| Sample volume | 50–100 µL plasma per test |
| Reagent volume | 50–100 µL per test |
| Measuring range | PT 5–100 s; APTT 15–150 s |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI H57, CLSI H21
This analyzer detects clot formation optically by measuring the change in light scatter as fibrin forms in the cuvette. It is the most common semi-automatic design and suits clinics and laboratories that need reliable prothrombin time and APTT results in small batches.
This analyzer detects clot formation optically by measuring the change in light scatter as fibrin forms in the cuvette. It is the most common semi-automatic design and suits clinics and laboratories that need reliable prothrombin time and APTT results in small batches.
A light source and photodetector are positioned across a temperature-controlled cuvette, and the instrument records transmitted or scattered light continuously after reagent addition. As fibrin strands form, scatter increases and the instrument marks the clotting point when the signal change exceeds a defined threshold, usually with a selectable sensitivity. Two or four measuring channels run in parallel, and incubation positions pre-warm plasma and reagent to 37 degrees Celsius. The analyzer stores calibration curves for each reagent lot and calculates the prothrombin time ratio and international normalised ratio from the international sensitivity index. Because detection depends on an optical signal, samples that are icteric, hemolyzed or lipemic should be flagged, and the instrument prompt for such samples is a useful quality feature.
A semi-automatic coagulation analyzer provides a temperature-controlled measuring position, usually at 37 degrees Celsius, a detection system and a timer. The operator pipettes plasma into the cuvette, incubates it, adds the reagent and starts the measurement. Optical instruments detect the increase in turbidity or the change in light scatter as fibrin strands form; mechanical instruments detect the change in movement or viscosity of a steel ball or magnetic particle; turbidimetric and chromogenic instruments measure light absorption changes from the fibrin network or from a coloured product released by a synthetic substrate. The analyzer stops the timer at the detection threshold and reports the clotting time in seconds, a ratio for prothrombin time or a concentration for fibrinogen. Because sample and reagent handling remain manual, pipetting accuracy and consistent incubation timing have a large influence on results.
A typical semi-automatic coagulation analyzer with optical clot detection configuration offers detection principle of Optical scatter change, 660 nm LED, channels of 2 or 4 parallel measurement channels, incubation temperature of 37 °C ±0.3 °C, sample volume of 50–100 µL plasma per test, reagent volume of 50–100 µL per test and measuring range of PT 5–100 s; APTT 15–150 s. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Semi-Automatic Coagulation Analyzer with Optical Clot Detection is used in routine PT and APTT testing in clinics, INR monitoring in anticoagulation clinics, pre-operative coagulation screening and thrombin time and fibrinogen measurement. Across the wider Semi-Automatic Coagulation Analyzers class, laboratories also deploy it for routine PT and APTT testing in clinics, anticoagulation monitoring with INR and pre-operative coagulation screening.
Relevant standards and methods include ISO 15189, CLSI H57, CLSI H21, CLSI EP05, ICSH recommendations on coagulation testing, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the analyzer on a level bench away from vibration and draughts, since both disturb optical clot detection, and allow the instrument to reach and hold 37 degrees Celsius before use. Verify performance at installation against a reference instrument or assigned plasma samples for prothrombin time, APTT and fibrinogen, and check the incubation temperature with an external thermometer. Daily work includes running normal and abnormal control plasma, checking reagent and cuvette lot numbers and recording all values. Reagents must be reconstituted, stored and expired strictly according to the instructions, and citrated plasma should be separated, frozen and thawed under controlled conditions because pre-analytical handling has a large influence on clotting times.
Specify this variant when plasma samples are typically clear and the menu is limited to clotting time assays. In the RFQ confirm the number of channels, the incubation temperature specification, whether the international sensitivity index can be entered per reagent lot, and how the instrument handles samples that are visibly lipemic or icteric.
Choose the detection principle according to the samples you receive: mechanical or magnetic detection tolerates icteric, hemolyzed and lipemic plasma, while optical detection is simpler and usually requires a clear sample. Then decide how many channels you need, because a four-channel instrument allows several patients or duplicate measurements in one run and reduces operator waiting time. Check the menu the instrument supports, especially whether fibrinogen, D-dimer or antithrombin assays are available, since not every semi-automatic platform can perform chromogenic or immunoturbidimetric tests. Confirm the sample and reagent volumes, the incubation temperature accuracy and the calibration requirements, and ask whether the analyzer stores calibrator values for each reagent lot.
| Detection principle | Optical scatter change, 660 nm LED |
|---|---|
| Channels | 2 or 4 parallel measurement channels |
| Incubation temperature | 37 °C ±0.3 °C |
| Sample volume | 50–100 µL plasma per test |
| Reagent volume | 50–100 µL per test |
| Measuring range | PT 5–100 s; APTT 15–150 s |
| Calibration | Stored curves per reagent lot with ISI input |
| Data storage | 1,000 patient results with control records |
| Power supply | AC 100–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
The instrument monitors the optical signal continuously and marks the point where the change exceeds a threshold defined by the manufacturer or selected by the user. Threshold choice affects the measured time slightly, so the same setting should be used consistently for a given reagent and assay.
Usually not, because D-dimer requires an immunoturbidimetric measurement with specific latex reagent and calibration, which semi-automatic optical coagulation channels do not provide. Laboratories needing D-dimer should select an analyzer with an immunoturbidimetric module or use a dedicated platform.
Common causes are insufficient plasma or reagent volume, air bubbles in the cuvette, reagent that was not fully reconstituted, a plasma sample with very low fibrinogen, and strong turbidity or haemolysis. The instrument usually reports an error, and the sample should be re-run after checking the indicated cause.
No, most semi-automatic optical analyzers include prewarming positions or a heated chamber for plasma and reagent. Confirm the number of prewarm positions, since a single position can slow the workflow when several samples are prepared at the same time.
Typically prothrombin time, activated partial thromboplastin time, thrombin time and fibrinogen, with derived results such as the international normalised ratio. Chromogenic and immunoturbidimetric assays such as antithrombin and D-dimer are available only on platforms designed for them, so check the menu before purchase.
Two channels allow a patient sample and a control in one run, while four channels support duplicate measurements or several patients. More channels reduce waiting time but also increase reagent consumption, so choose according to daily sample count and the proportion of urgent requests.
Icteric, hemolyzed and lipemic plasma change light transmission and can delay or advance the detected clot point, and very low fibrinogen produces a weak signal. Mechanical or magnetic detection is less affected, and samples with these characteristics should be flagged or measured on such a system.

机械凝固检测半自动凝血分析仪


具显色法功能的半自动凝血分析仪