FTIR Spectrometer for Rubber Identification
橡胶鉴别用红外光谱仪
- SKU RCA-0002
- Rubber Composition Analysis
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Spectral range | 4000–400 cm⁻¹ |
|---|---|
| Resolution | 1–4 cm⁻¹ |
| Signal-to-noise ratio | Better than 20,000:1 at 4 cm⁻¹ |
| ATR crystal | Diamond, single reflection |
| Pyrolysis accessory | Optional, for cured compounds |
| Sampling depth | About 2 µm at 1000 cm⁻¹ |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 9924-1, ISO 9924-2, ISO 1407
What is the FTIR Spectrometer for Rubber Identification?
An FTIR spectrometer identifies the elastomer type in a rubber compound from its characteristic infrared absorption bands. It is the standardised first step for identifying natural rubber, SBR, nitrile, EPDM, butyl and chloroprene.
What is the FTIR Spectrometer for Rubber Identification?
An FTIR spectrometer identifies the elastomer type in a rubber compound from its characteristic infrared absorption bands. It is the standardised first step for identifying natural rubber, SBR, nitrile, EPDM, butyl and chloroprene.
Overview
Rubber identification by infrared is standardised in ISO 4650 and ASTM D3677, which describe either direct measurement of a thin film or pyrolysate measurement for vulcanised and highly filled compounds. Direct examination by attenuated total reflection gives a rapid answer for the surface but is affected by migrated waxes, oils and bloom, so a solvent-extracted or microtomed surface may be needed. Characteristic band positions distinguish the common elastomers, and additional bands reveal chlorinated polymers, nitrile content and the presence of ester plasticisers. Because fillers such as carbon black scatter strongly, highly loaded compounds are often examined by pyrolysis or by diffuse reflectance, and the spectra are then compared with reference data rather than interpreted from first principles.
How does it work?
Rubber is a complex mixture, so several techniques are combined. Thermogravimetric analysis decomposes the sample in a staged nitrogen and oxygen atmosphere, giving the polymer fraction, carbon black and the inorganic residue in one run. Infrared spectrometry identifies the elastomer through its characteristic absorption bands and is standardised for rubber identification. Pyrolysis gas chromatography separates the products of thermal fragmentation and identifies copolymers and additives that spectroscopy cannot resolve. Solvent extraction removes plasticisers, process oils, waxes and free sulfur, which are then quantified by mass difference or by chromatography. X-ray fluorescence or elemental analysis measures the inorganic components, including zinc oxide, silica and sulfur-containing additives, that remain in the ash.
What are the key features?
- Diamond ATR for solid rubber surfaces
- Pyrolysis accessory for cured and filled compounds
- Library covering common elastomer types
- Spectral range of 4000–400 cm⁻¹
- Nitrile content indication from band ratios
- Minimal preparation for rapid screening
What are the technical specifications?
A typical ftir spectrometer for rubber identification configuration offers spectral range of 4000–400 cm⁻¹, resolution of 1–4 cm⁻¹, signal-to-noise ratio of Better than 20,000:1 at 4 cm⁻¹, ATR crystal of Diamond, single reflection, pyrolysis accessory of Optional, for cured compounds and sampling depth of About 2 µm at 1000 cm⁻¹. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The FTIR Spectrometer for Rubber Identification is used in elastomer identification in incoming inspection, verification of blend composition in failed parts, detection of surface bloom and migration and confirmation of polymer type before composition analysis. Across the wider Rubber Composition Analysis class, laboratories also deploy it for filler, carbon black and polymer content determination, elastomer identification in incoming inspection and plasticiser and process oil content testing.
Which standards and certifications apply?
Relevant standards and methods include ISO 9924-1, ISO 9924-2, ISO 1407, ISO 4650, ASTM D6370, ASTM D297, ASTM D3452, ASTM D3677 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Sampling is the dominant source of error, because fillers and oils are distributed unevenly in a finished rubber article. Cut specimens from several locations, or mill and homogenise the sample before taking portions, and record the sampling plan. For thermogravimetric analysis, fix the temperature programme and atmosphere switching, and subtract a crucible blank, since incomplete carbon burn-off is the commonest cause of inflated filler results. Clean infrared crystals after every measurement, since migrated oil and wax contaminate the surface. Solvent extraction requires maintenance of the extraction thimble and solvent purity, and the extracted mass must be measured after conditioning, because these materials are volatile and hygroscopic.
How do I select the right FTIR Spectrometer for Rubber Identification?
Choose infrared identification when polymer type must be established quickly, and add a pyrolysis accessory if cured, black-filled compounds are routine. Confirm that the library covers the elastomer families you handle, and plan solvent extraction or microtoming when surface contamination is likely, since bloom and migrated oils can mask the polymer bands.
How does it compare with other Rubber Composition Analysis variants?
Begin with the question. Thermogravimetric analysis is the fastest route to filler, carbon black and polymer content and can be run on any compound, so it suits routine incoming checks and rubber process control. Infrared identification is the standard first step for polymer type and is fast and cheap. Where the identity of a plasticiser or an unknown additive matters, pyrolysis gas chromatography is required for separation. Solvent extraction is used when the content of extractable material is the specification parameter, for example in rubber products with limits on plasticiser or on free sulfur. Elemental methods complete the picture for zinc, sulfur and other inorganic components, and are also the confirmation step for results that a screening technique suggests.
Full specifications
| Spectral range | 4000–400 cm⁻¹ |
|---|---|
| Resolution | 1–4 cm⁻¹ |
| Signal-to-noise ratio | Better than 20,000:1 at 4 cm⁻¹ |
| ATR crystal | Diamond, single reflection |
| Pyrolysis accessory | Optional, for cured compounds |
| Sampling depth | About 2 µm at 1000 cm⁻¹ |
| Library capacity | Elastomer and additive reference spectra |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Elastomer identification in incoming inspection
- Verification of blend composition in failed parts
- Detection of surface bloom and migration
- Confirmation of polymer type before composition analysis
Key features
- Diamond ATR for solid rubber surfaces
- Pyrolysis accessory for cured and filled compounds
- Library covering common elastomer types
- Spectral range of 4000–400 cm⁻¹
- Nitrile content indication from band ratios
- Minimal preparation for rapid screening
Frequently asked questions about FTIR Spectrometer for Rubber Identification
Cured and carbon black filled rubbers are difficult to measure directly because carbon black absorbs and scatters infrared radiation strongly, and the crosslinked network cannot be dissolved to form a film. Pyrolysis breaks the rubber into characteristic fragments that can be collected and measured, and standard methods cover this approach.
It can give a semiquantitative indication from the ratio of the nitrile band near 2237 cm⁻¹ to a polymer backbone band, or of the acrylate carbonyl to the backbone. For specification purposes, calibrations must be established with compounds of known composition, because filler and oil content also influence band intensity.
Wipe the surface with a suitable solvent or microtome a thin layer away to expose the bulk compound, then measure again. Comparing the two spectra shows exactly which bands belong to the bloom, which is itself useful information when diagnosing adhesion or appearance problems.
Thermogravimetric analysis gives the most information per run: polymer content from the first weight loss, carbon black from the oxidative stage and inorganic filler as the residue. The result is available in under an hour and requires only a few milligrams, which is why it is the usual starting point for compound verification.
It measures the material soluble in hot acetone, which includes plasticisers, some process oils, waxes, accelerators, antioxidants and free sulfur. The amount is expressed as a percentage of the specimen mass, and the extract can be analysed further by chromatography to identify individual components.
Fillers, oils and curatives are not uniformly distributed in a finished part, and the surface may differ from the core because of migration and moulding flow. Several specimens from defined locations, or a milled and homogenised sample, are needed for a representative result, and the sampling plan should be reported with the data.